Principles, Techniques, and Limitations of Near Infrared Spectroscopy
The DOI matches its Crossref record; 114 of the 114 references it cites were found in a registry or an index.
Abstract
In the last decade the study of the human brain and muscle energetics underwent a radical change, thanks to the progressive introduction of noninvasive techniques, including near-infrared (NIR) spectroscopy (NIRS). This review summarizes the most recent literature about the principles, techniques, advantages, limitations, and applications of NIRS in exercise physiology and neuroscience. The main NIRS instrumentations and measurable parameters will be reported. NIR light (700-1000 nm) penetrates superficial layers (skin, subcutaneous fat, skull, etc.) and is either absorbed by chromophores (oxy- and deoxyhemoglobin and myoglobin) or scattered within the tissue. NIRS is a noninvasive and relatively low-cost optical technique that is becoming a widely used instrument for measuring tissue O 2 saturation, changes in hemoglobin volume and, indirectly, brain/muscle blood flow and muscle O 2 consumption. Tissue O 2 saturation represents a dynamic balance between O 2 supply and O 2 consumption in the small vessels such as the capillary, arteriolar, and venular bed. The possibility of measuring the cortical activation in response to different stimuli, and the changes in the cortical cytochrome oxidase redox state upon O 2 delivery changes, will also be mentioned. Key words: tissue oximetry, oxidative metabolism, optical imaging, blood flow, oxygen consumption, exercise physiology
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These values are in a large part representative of tissue capillaries, arterioles, and venules because, in larger blood vessels, NIR light is fully absorbed by the high hemoglobin concentration. 4”
From Performance comparison of the MOXY and PortaMon near-infrared spectroscopy muscle oximeters at rest and during exercise (2018) · cites this paper as [4]
In the citing paper
“Furthermore, small differences in ambient and muscular temperature may influence day-today variability, 4 as may slight changes in posture. 38”
From Performance comparison of the MOXY and PortaMon near-infrared spectroscopy muscle oximeters at rest and during exercise (2018) · cites this paper as [4]
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Strangman, G., Culver, J. P., Thompson, J. H., & Boas, D. A. (2002) · NeuroImage · doi:10.1006/nimg.2002.1227 · Cited by 1,415
Recent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
Non-invasive neuroimaging using near-infrared light
Strangman, G., Boas, D. A., & Sutton, J. P. (2002) · Biological Psychiatry · doi:10.1016/s0006-3223(02)01550-0 · Cited by 903
Beyond the Visible???Imaging the Human Brain With Light
Obrig, H., & Villringer, A. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200301000-00001 · Cited by 892
Owen-Reece, H., Smith, M., Elwell, C. E., & Goldstone, J. C. (1999) · British Journal of Anaesthesia · doi:10.1093/bja/82.3.418 · Cited by 688
Spontaneous Low Frequency Oscillations of Cerebral Hemodynamics and Metabolism in Human Adults
Obrig, H., Neufang, M., Wenzel, R., Kohl, M., Steinbrink, J., Einhäupl, K., & Villringer, A. (2000) · NeuroImage · doi:10.1006/nimg.2000.0657 · Cited by 614
Wittenberg, J. B., & Wittenberg, B. A. (2003) · Journal of Experimental Biology · doi:10.1242/jeb.00243 · Cited by 550
Functional near‐infrared optical imaging: Utility and limitations in human brain mapping
Hoshi, Y. (2003) · Psychophysiology · doi:10.1111/1469-8986.00053 · Cited by 532
Recovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528
Quantification in tissue near–infrared spectroscopy
Delpy, D. T., & Cope, M. (1997) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1997.0046 · Cited by 507
Tissue oxygenation monitor using NIR spatially resolved spectroscopy:
Suzuki, S., Takasaki, S., Ozaki, T., & Kobayashi, Y. (1999) · SPIE Proceedings · doi:10.1117/12.356862 · Cited by 484
Monitoring tissue oxygen availability with near infrared spectroscopy (NIRS) in health and disease
Boushel, R., Langberg, H., Olesen, J., Gonzales‐Alonzo, J., Bülow, J., & Kjær, M. (2001) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1034/j.1600-0838.2001.110404.x · Cited by 469
Kleinschmidt, A., Obrig, H., Requardt, M., Merboldt, K.-D., Dirnagl, U., Villringer, A., & Frahm, J. (1996) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199609000-00006 · Cited by 456
Van Beekvelt, M. C. P., Colier, W. N. J. M., Wevers, R. A., & Van Engelen, B. G. M. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.2.511 · Cited by 430
Grassi, B., Pogliaghi, S., Rampichini, S., Quaresima, V., Ferrari, M., Marconi, C., & Cerretelli, P. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00695.2002 · Cited by 429
Self-citationCognition-activated low-frequency modulation of light absorption in human brain.
Chance, B., Zhuang, Z., UnAh, C., Alter, C., & Lipton, L. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.8.3770 · Cited by 426
Toronov, V., Webb, A., Choi, J. H., Wolf, M., Michalos, A., Gratton, E., & Hueber, D. (2001) · Medical Physics · doi:10.1118/1.1354627 · Cited by 380
Adipose tissue thickness affects in vivo quantitative near-IR spectroscopy in human skeletal muscle
VAN BEEKVELT, M. C. P., BORGHUIS, M. S., VAN ENGELEN, B. G. M., WEVERS, R. A., & COLIER, W. N. J. M. (2001) · Clinical Science · doi:10.1042/cs1010021 · Cited by 369
Syncope, cerebral perfusion, and oxygenation
Van Lieshout, J. J., Wieling, W., Karemaker, J. M., & Secher, N. H. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00260.2002 · Cited by 365 · cited 2×
“From anatomical studies of the brain, the ratio of venule to total vessel volume ranges from 2/3 to 4/5 (van Lieshout et al., 2003).”
BackgroundOkada, E., & Delpy, D. T. (2003) · Applied Optics · doi:10.1364/ao.42.002915 · Cited by 364
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Self-citationNear-infrared oximetry of the brain
Madsen, P. L., & Secher, N. H. (1999) · Progress in Neurobiology · doi:10.1016/s0301-0082(98)00093-8 · Cited by 315
Near‐infrared spectroscopy for monitoring muscle oxygenation
Boushel, R., & Piantadosi, C. A. (2000) · Acta Physiologica Scandinavica · doi:10.1046/j.1365-201x.2000.00713.x · Cited by 299
Noninvasive measurement of forearm blood flow and oxygen consumption by near-infrared spectroscopy
De Blasi, R. A., Ferrari, M., Natali, A., Conti, G., Mega, A., & Gasparetto, A. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.76.3.1388 · Cited by 292
Self-citationThree-dimensional optical tomography of the premature infant brain
Hebden, J. C., Gibson, A., Yusof, R. M., Everdell, N., Hillman, E. M. C., Delpy, D. T., Arridge, S. R., Austin, T., Meek, J. H., & Wyatt, J. S. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/23/303 · Cited by 288
Noninvasive measures of oxidative metabolism on working human muscles by near-infrared spectroscopy
Hamaoka, T., Iwane, H., Shimomitsu, T., Katsumura, T., Murase, N., Nishio, S., Osada, T., Kurosawa, Y., & Chance, B. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.3.1410 · Cited by 280
Al-Rawi, P. G., Smielewski, P., & Kirkpatrick, P. J. (2001) · Stroke · doi:10.1161/hs1101.098356 · Cited by 273
In Vivo Near-Infrared Spectroscopy
Rolfe, P. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.715 · Cited by 273
Mehagnoul‐Schipper, D. J., van der Kallen, B. F. W., Colier, W. N. J. M., van der Sluijs, M. C., van Erning, L. J. T. O., Thijssen, H. O. M., Oeseburg, B., Hoefnagels, W. H. L., & Jansen, R. W. M. M. (2002) · Human Brain Mapping · doi:10.1002/hbm.10026 · Cited by 264 · cited 2×
“Kleinschmidt et al. (1996) first measured simultaneously cerebral oxygenation changes during human brain motor activation by fMRI and one-channel fNIRS. fNIRS and fMRI measurements showed good correlation in young and elderly subjects during a motor task (Mehagnoul-Schipper et al., 2002).”
BackgroundMethodBlood lactate accumulation and muscle deoxygenation during incremental exercise
Grassi, B., Quaresima, V., Marconi, C., Ferrari, M., & Cerretelli, P. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.1.348 · Cited by 248
Self-citationOxidative metabolism in muscle
Ferrari, M., Binzoni, T., & Quaresima, V. (1997) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1997.0049 · Cited by 247
Self-citationNoninvasive measurement of human forearm oxygen consumption by near infrared spectroscopy
De Blasi, R. A., Cope, M., Elwell, C., Safoue, F., & Ferrari, M. (1993) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00377698 · Cited by 238
Self-citationMcCully, K. K., Iotti, S., Kendrick, K., Wang, Z., Posner, J. D., Leigh, J., & Chance, B. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.1.5 · Cited by 228
A Tissue Oxygenation Monitor using NIR Spatially Resolved Spectroscopy
Suzuki, S. (1999) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · Cited by 227
Muscle oxygen kinetics at onset of intense dynamic exercise in humans
Bangsbo, J., Krustrup, P., González-Alonso, J., Boushel, R., & Saltin, B. (2000) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.2000.279.3.r899 · Cited by 220
Wolf, M., Wolf, U., Toronov, V., Michalos, A., Paunescu, L. A., Choi, J. H., & Gratton, E. (2002) · NeuroImage · doi:10.1006/nimg.2002.1128 · Cited by 197
Hoshi, Y., Oda, I., Wada, Y., Ito, Y., Yamashita, Y., Oda, M., Ohta, K., Yamada, Y., & Tamura, M. (2000) · Cognitive Brain Research · doi:10.1016/s0926-6410(00)00006-9 · Cited by 195
Comparative analysis of NMR and NIRS measurements of intracellular P O 2 in human skeletal muscle
Tran, T.-K., Sailasuta, N., Kreutzer, U., Hurd, R., Chung, Y., Mole, P., Kuno, S., & Jue, T. (1999) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1999.276.6.r1682 · Cited by 175
Toronov, V., Franceschini, M. A., Filiaci, M., Fantini, S., Wolf, M., Michalos, A., & Gratton, E. (2000) · Medical Physics · doi:10.1118/1.598943 · Cited by 169
Thavasothy, M., Broadhead, M., Elwell, C., Peters, M., & Smith, M. (2002) · Anaesthesia · doi:10.1046/j.1365-2044.2002.02826.x · Cited by 165 · cited 1×
“Thavasothy et al. (2002) compared the cerebral cortex oxygenation as measured by the NIRO-300 and the INVOS 5100 (Somanetics, Troy, MI).”
MethodBoushel, R., Langberg, H., Olesen, J., Nowak, M., Simonsen, L., Bülow, J., & Kjær, M. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.5.1868 · Cited by 163
Zhao, H., Tanikawa, Y., Gao, F., Onodera, Y., Sassaroli, A., Tanaka, K., & Yamada, Y. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/12/306 · Cited by 152
Blood flow and oxygenation in peritendinous tissue and calf muscle during dynamic exercise in humans
Boushel, R., Langberg, H., Green, S., Skovgaard, D., Bülow, J., & Kjær, M. (2000) · The Journal of Physiology · doi:10.1111/j.1469-7793.2000.t01-2-00305.x · Cited by 151
Muscle Oxygenation Trends During Dynamic Exercise Measured by Near Infrared Spectroscopy
Bhambhani, Y. N. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-033 · Cited by 149
Time resolved optical tomography of the human forearm
Hillman, E. M. C., Hebden, J. C., Schweiger, M., Dehghani, H., Schmidt, F. E. W., Delpy, D. T., & Arridge, S. R. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/4/315 · Cited by 146
Van Beekvelt, M. C. P., Van Engelen, B. G. M., Wevers, R. A., & Colier, W. N. J. M. (2002) · Clinical Physiology and Functional Imaging · doi:10.1046/j.1475-097x.2002.00420.x · Cited by 146
Uludaǧ, K., Kohl‐Bareis, M., Steinbrink, J. M., Obrig, H., & Villringer, A. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1427048 · Cited by 139
Time-resolved spectroscopy of the human forearm
Ferrari, M., Wei, Q., Carraresi, L., Blasi, R. A. D., & Zaccanti, G. (1992) · Journal of Photochemistry and Photobiology B Biology · doi:10.1016/1011-1344(92)80005-g · Cited by 138
Self-citationMuscle metabolism from near infrared spectroscopy during rhythmic handgrip in humans
Boushel, R., Pott, F. C., Madsen, P. L., R�degran, G., Nowak, M., Quistorff, B., & Secher, N. H. (1998) · European Journal of Applied Physiology · doi:10.1007/s004210050471 · Cited by 133
Sako, T., Hamaoka, T., Higuchi, H., Kurosawa, Y., & Katsumura, T. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.1.338 · Cited by 132
Wobst, P., Wenzel, R., Kohl‐Bareis, M., Obrig, H., & Villringer, A. (2001) · NeuroImage · doi:10.1006/nimg.2000.0706 · Cited by 128
Cerebral hemodynamics measured with simultaneous PET and near-infrared spectroscopy in humans
Rostrup, E., Law, I. G., Pott, F. C., Ide, K., & Knudsen, G. M. (2002) · Brain Research · doi:10.1016/s0006-8993(02)03246-8 · Cited by 124
Homma, S., Eda, H., Ogasawara, S., & Kagaya, A. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.80.4.1279 · Cited by 123
Quantitative Near Infrared Spectroscopy Measurement of Cerebral Hemodynamics in Newborn Piglets
Brown, D. W., Picot, P. A., Gharavi, J., Springett, R., Delpy, D. T., & Lee, T. (2002) · Pediatric Research · doi:10.1203/00006450-200205000-00004 · Cited by 122
Kennan, R. P., Horovitz, S. G., Maki, A., Yamashita, Y., Koizumi, H., & Gore, J. C. (2002) · NeuroImage · doi:10.1006/nimg.2002.1060 · Cited by 121
Kennan, R. P., Kim, D., Maki, A., Koizumi, H., & Constable, R. T. (2002) · Human Brain Mapping · doi:10.1002/hbm.10039 · Cited by 119
Quaresima, V., Ferrari, M., van der Sluijs, M. C., Menssen, J., & Colier, W. N. J. M. (2002) · Brain Research Bulletin · doi:10.1016/s0361-9230(02)00871-7 · Cited by 118
Self-citationMancini, D. M., Wilson, J. R., Bolinger, L., Li, H., Kendrick, K., Chance, B., & Leigh, J. S. (1994) · Circulation · doi:10.1161/01.cir.90.1.500 · Cited by 108
Cooper, C. E., Cope, M., Springett, R., Amess, P., Penrice, J., Tyszczuk, L., Punwani, S., Ordidge, R. J., Wyatt, J. S., & Delpy, D. T. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199901000-00003 · Cited by 104
Costes, F., Barthelemy, J. C., Feasson, L., Busso, T., Geyssant, A., & Denis, C. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.80.4.1345 · Cited by 101 · cited 2×
“In support of the effect of apparent sample volume during prolonged exercise, some studies have shown that the magnitude of the partial recovery in muscle oxygenation during exercise was reduced during hypoxia (Costes et al., 1996; MacDonald et al., 1999).”
BackgroundComparison of femoral blood gases and muscle near-infrared spectroscopy at exercise onset in humans
MacDonald, M. J., Tarnopolsky, M. A., Green, H. J., & Hughson, R. L. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.2.687 · Cited by 98 · cited 2×
“In support of the effect of apparent sample volume during prolonged exercise, some studies have shown that the magnitude of the partial recovery in muscle oxygenation during exercise was reduced during hypoxia (Costes et al., 1996; MacDonald et al., 1999).”
BackgroundKohri, S., Hoshi, Y., Tamura, M., Kato, C., Kuge, Y., & Tamaki, N. (2002) · Physiological Measurement · doi:10.1088/0967-3334/23/2/306 · Cited by 97
Redox behavior of cytochrome oxidase in the rat brain measured by near-infrared spectroscopy
Hoshi, Y., Hazeki, O., Kakihana, Y., & Tamura, M. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.83.6.1842 · Cited by 96
Franceschini, M. A., Boas, D. A., Zourabian, A., Diamond, S. G., Nadgir, S., Lin, D. W., Moore, J. B., & Fantini, S. (2002) · Journal of Applied Physiology · doi:10.1152/jappl.2002.92.1.372 · Cited by 95
Kohl‐Bareis, M., Obrig, H., Steinbrink, J., Malak, J., Uludaǧ, K., & Villringer, A. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1482719 · Cited by 95
Niwayama, M., Lin, L., Shao, J., Kudo, N., & Yamamoto, K. (2000) · Review of Scientific Instruments · doi:10.1063/1.1322578 · Cited by 94
Wolf, M. (2002) · NeuroImage · doi:10.1006/nimg.2002.1261 · Cited by 92
Near-infrared time-resolved spectroscopy system for tissue oxygenation monitor:
Oda, M., Yamashita, Y., Nakano, T., Suzuki, A., Shimizu, K., Hirano, I., Shimomura, F., Ohmae, E., Suzuki, T., & Tsuchiya, Y. (1999) · SPIE Proceedings · doi:10.1117/12.356809 · Cited by 85
Gora, F., Shinde, S., Elwell, C. E., Goldstone, J. C., Cope, M., Delpy, D. T., & Smith, M. (2002) · Journal of Neurosurgical Anesthesiology · doi:10.1097/00008506-200207000-00008 · Cited by 78
Application of Near Infrared Spectroscopy to Exercise Sports Science
Neary, J. P. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-032 · Cited by 73
Determination of oxygen consumption in muscle during exercise using near infrared spectroscopy
COLIER, W. N. J. M., MEEUWSEN, I. B. A. E., DEGENS, H., & OESEBURG, B. (1995) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1995.tb04350.x · Cited by 69
Springett, R., Newman, J., Cope, M., & Delpy, D. T. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.279.5.h2202 · Cited by 69
Sakamoto, T., Jonas, R. A., Stock, U. A., Hatsuoka, S., Cope, M., Springett, R., & Nollert, G. (2001) · Pediatric Research · doi:10.1203/00006450-200106000-00010 · Cited by 68
Hopton, P., Walsh, T. S., & Lee, A. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.5.1981 · Cited by 68
YOXALL, C. W., & Weindling, A. M. (1997) · Medical & Biological Engineering & Computing · doi:10.1007/bf02534086 · Cited by 66
Miura, H., Araki, H., Matoba, H., & Kitagawa, K. (2000) · International Journal of Sports Medicine · doi:10.1055/s-2000-301 · Cited by 64
Effects of pedal frequency on estimated muscle microvascular O2 extraction
Ferreira, L. F., Lutjemeier, B. J., Townsend, D. K., & Barstow, T. J. (2005) · European Journal of Applied Physiology · doi:10.1007/s00421-005-0107-3 · Cited by 63
Nonuniform Quadriceps O2 Consumption Revealed by Near Infrared Multipoint Measurements
Quaresima, V., Colier, W. N. J. M., van der Sluijs, M. C., & Ferrari, M. (2001) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.2001.5292 · Cited by 61
Self-citationShimizu, S., Chiarotti, F., Ferrari, M., Kagaya, A., Quaresima, V., Homma, S. T., & Azuma, K. (2001) · European Journal of Applied Physiology · doi:10.1007/s004210100390 · Cited by 59
Self-citationBinzoni, T., Quaresima, V., Barattelli, G., Hiltbrand, E., Gürke, L., Terrier, F., Cerretelli, P., & Ferrari, M. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.4.1244 · Cited by 58
Self-citationInfluence of adipose tissue on muscle oxygenation measurement with an NIRS instrument:
Matsushita, K., Homma, S., & Okada, E. (1998) · SPIE Proceedings · doi:10.1117/12.301048 · Cited by 57
Development of a portable tissue oximeter using near infra-red spectroscopy
Shiga, T., Tanabe, K., Nakase, Y., Shida, T., & Chance, B. (1995) · Medical & Biological Engineering & Computing · doi:10.1007/bf02522525 · Cited by 57
Springett, R., Sakata, Y. S., & Delpy, D. T. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/8/312 · Cited by 55
Hicks, A., McGill, S. M., & Hughson, R. L. (1999) · Canadian Journal of Applied Physiology · doi:10.1139/h99-018 · Cited by 55
Miura, H., McCully, K., Hong, L., Nioka, S., & Chance, B. (2001) · The Japanese Journal of Physiology · doi:10.2170/jjphysiol.51.599 · Cited by 54
Deciphering the mysteries of myoglobin in striated muscle
Conley, K. E., Ordway, G. A., & Richardson, R. S. (2000) · Acta Physiologica Scandinavica · doi:10.1046/j.1365-201x.2000.00714.x · Cited by 53
Quaresima, V., Springett, R., Cope, M., Wyatt, J. S., Delpy, D. T., Ferrari, M., & Cooper, C. E. (1998) · Biochimica et Biophysica Acta (BBA) - Bioenergetics · doi:10.1016/s0005-2728(98)00129-7 · Cited by 53
Self-citationKusaka, T., Isobe, K., Nagano, K., Okubo, K., Yasuda, S., Kondo, M., Itoh, S., & Onishi, S. (2001) · NeuroImage · doi:10.1006/nimg.2001.0755 · Cited by 51
Fantini, S. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/18/402 · Cited by 51
Human calf microvascular compliance measured by near-infrared spectroscopy
Binzoni, T., Quaresima, V., Ferrari, M., Hiltbrand, E., & Cerretelli, P. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.88.2.369 · Cited by 51
Self-citationMeasurement of cerebral blood flow during cardiopulmonary bypass with near-infrared spectroscopy
Roberts, I. G., Fallon, P., Kirkham, F. J., Kirshbom, P. M., Cooper, C. E., Elliott, M. J., & Edwards, A. D. (1998) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(98)70447-7 · Cited by 50
De Blasi, R. A. (1997) · Journal of Biomedical Optics · doi:10.1117/12.269893 · Cited by 50
Self-citationOptical tomography of the neonatal brain
Hebden, J. C., & Austin, T. (2007) · European Radiology · doi:10.1007/s00330-007-0659-1 · Cited by 49
Non-Invasive Measurements of O2Availability in Human Skeletal Muscle with Near-Infrared Spectroscopy
Sahlin, K. (1992) · International Journal of Sports Medicine · doi:10.1055/s-2007-1024625 · Cited by 46
Near-infrared time-resolved spectroscopy system for tissue oxygenation monitor
Oda, M., Yamashita, Y., Nakano, T., Suzuki, A., Shimizu, K., Hirano, I., Shimomura, F., Ohmae, E., Suzuki, T., & Tsuchiya, Y. (2000) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.407622 · Cited by 43
Maintenance of myoglobin concentration in human skeletal muscle after heavy resistance training
Masuda, K., Choi, J. Y., Shimojo, H., & Katsuta, S. (1999) · European Journal of Applied Physiology · doi:10.1007/s004210050519 · Cited by 38
Oxygen Dependency of Cerebral Oxidative Phosphorylation in Newborn Piglets
Springett, R., Wylezinska, M., Cady, E. B., Cope, M., & Delpy, D. T. (2000) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200002000-00009 · Cited by 35
KOMIYAMA, T., QUARESIMA, V., SHIGEMATSU, H., & FERRARI, M. (2001) · Clinical Science · doi:10.1042/cs1010715 · Cited by 31 · cited 4×
“Conversely, at rest the intramuscular O 2 stores, as measured by NIRS during suprasystolic cuff occlusion, begin to decrease immediately after the beginning of the occlusion and the maximal desaturation is achieved after 5–6 min (Komiyama et al., 2001).”
BackgroundMethodInfluentialSelf-citationNewton, C. R. J. C., Wilson, D. A., Gunnoe, E., Wagner, B., Cope, M., & Traystman, R. J. (1997) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199706000-00011 · Cited by 31
Richardson, R. S., Noyszewski, E. A., Saltin, B., & González-Alonso, J. (2002) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00226.2002 · Cited by 31
Near-infrared spectroscopy in the assessment of cerebral oxygenation at high altitude
Imray, C., Barnett, N. J., Walsh, S. K., Clarke, T., Morgan, J., Hale, D., Hoar, H., Mole, D. J., Chesner, I. M., & Wright, A. D. (1998) · Wilderness and Environmental Medicine · doi:10.1580/1080-6032(1998)009[0198:nisita]2.3.co;2 · Cited by 30
van de Ven, M. J. T., Colier, W. N. J. M., van der Sluijs, M. C., Walraven, D., Oeseburg, B., & Folgering, H. T. M. (2001) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200102000-00002 · Cited by 29
Differences in oxygen re-saturation of thigh and calf muscles after two treadmill stress tests
Quaresima, V., Komiyama, T., & Ferrari, M. (2002) · Comparative Biochemistry and Physiology Part A Molecular & Integrative Physiology · doi:10.1016/s1095-6433(01)00531-1 · Cited by 29
Self-citationMuscle Oxygenation of the Paralyzed Lower Limb in Spinal Cord???Injured Persons
Kawashima, N., Nakazawa, K., & Akai, M. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000170488.86528.08 · Cited by 27
De Visscher, G., Springett, R., Delpy, D. T., Van Reempts, J., Borgers, M., & van Rossem, K. (2002) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200205000-00002 · Cited by 24
Wolf, M., von Siebenthal, K., Keel, M., Dietz, V., Baenziger, O., & Bucher, H. U. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1463044 · Cited by 22
The Contribution of NMR, NIRS and their Combination to the Functional Assessment of Human Muscle
Cerretelli, P., & Binzoni, T. (1997) · International Journal of Sports Medicine · doi:10.1055/s-2007-972724 · Cited by 19
A Tentative Proposal on Physiological Polymorphism and Its Experimental Approaches
Miyazaki, Y., & Tsunetsugu, Y. (2005) · Journal of PHYSIOLOGICAL ANTHROPOLOGY and Applied Human Science · doi:10.2114/jpa.24.297 · Cited by 16
Investigation of rat breast tumour oxygen consumption by near-infrared spectroscopy
Song, Y., Kim, J. G., Mason, R. P., & Liu, H. (2005) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/38/15/021 · Cited by 15
Continuous-wave near-infrared spectroscopy using pathlength-independent hypoxia normalization
Kennan, R. P., & Behar, K. L. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1463048 · Cited by 7
Venous-Arteriolar Reflex in Human Gastrocnemius Studied by NIRS
Binzoni, T., Ngo, L., Girardis, M., Springett, R., Terrier, F., & Delpy, D. T. (2003) · Advances in experimental medicine and biology · doi:10.1007/978-1-4615-0075-9_44 · Cited by 4
Multimodality neuromonitoring for perioperative brain protection
Edmonds, H. L. (2005) · Seminars in Anesthesia Perioperative Medicine and Pain · doi:10.1053/j.sane.2005.10.004 · Cited by 4
Pagani, M., Ansjon, R., Lind, F., Jonsson, C., Uusijärvi, J., Sumen, G., Jacobsson, H., & Larsson, S. (1998) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.301047 · Cited by 3
Research works printed but not linked: 6
- Bangsbo J., 2000, Am. J. Physiol., 279, R899
- McCully K.K., 2000, Exerc. Sport Sci. Rev., 28, 123
- Obrig H., 2003, J. Cereb. Blood Flow Metab., 23, 1, 10.1097/01.wcb.0000043472.45775.29 · DOI · Paper page
- Richardson R.S., 2002, Am. J. Physiol., 283, R1131
- Springett R., 2000, Am. J. Physiol., 279, H2202
- Tran T.K., 1999, Am. J. Physiol., 276, R1682
Cited by
Ferrari, M., & Quaresima, V. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.049 · Cited by 2,274
“Different NIRS instruments with related key features, advantages and disadvantages, and parameters measurable by using different NIRS techniques have been reviewed in detail elsewhere (Ferrari et al., 2004; Wolf et al., 2007) and summarized in Table 2.”
MethodSelf-citationScholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002
Recent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
fNIRS-based brain-computer interfaces: a review
Naseer, N., & Hong, K.-S. (2015) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2015.00003 · Cited by 988
“…et al., 2008; Sardouie and Shamsollahi, 2012), functional magnetic resonance imaging (fMRI) (Weiskopf et al., 2004; LaConte, 2011; van der Heiden et al., 2014), and fNIRS (Ferrari et al., 1985, 2004; Kato et al., 1993; Hu et al., 2013; Bhutta et al., 2014; Rea et al., 2014; Santosa et al., 2014).”
BackgroundLloyd-Fox, S., Blasi, A., & Elwell, C. E. (2010) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2009.07.008 · Cited by 865
Metadata
- Authors
- Ferrari, M., Mottola, L., & Quaresima, V.
- Affiliations
- University of L'Aquila (IT)
- Casa Sollievo della Sofferenza (IT)
- Kyoto University (JP)
- Venue
- Canadian Journal of Applied Physiology
- Publisher
- Canadian Science Publishing
- Published
- 2004-08-01
- Volume
- 29
- Issue
- 4
- Pages
- 463-487
- ISSN
- 1066-7814 (ISSN-L)
- OpenAlex
- W2130603606
- Cited by
- 997
- References
- 114
- Citations by year
- 2026: 35 · 2025: 51 · 2024: 44 · 2023: 58 · 2022: 53 · 2021: 46 · 2020: 53 · 2019: 55 · 2018: 54 · 2017: 63 · 2016: 48 · 2015: 52 · 2014: 36 · 2013: 56 · 2012: 68
- FWCI
- 4.61
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.nrcresearchpress.com/page/about/CorporateTextAndDataMining (tdm)
- Locations
- Canadian Journal of Applied Physiology (publishedVersion)
- PubMed (publishedVersion)
- Archivio Istituzionale della Ricerca - Università degli Studi dell Aquila (submittedVersion)
- Funders
- U.S. Food and Drug Administration
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Keywords
- near-infrared spectroscopy, tissue oxygen saturation, hemoglobin, myoglobin, muscle oxygen consumption, cerebral blood flow, brain energy metabolism, cortical activation, cytochrome c oxidase, light scattering, exercise physiology, non-invasive optical measurement
- MeSH terms
- Blood Volume, Cerebral Cortex, Cerebrovascular Circulation, Humans, Oximetry, Oxygen Consumption, Regional Blood Flow, Muscle, Skeletal, Spectroscopy, Near-Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.