Principles, Techniques, and Limitations of Near Infrared Spectroscopy
The DOI matches its Crossref record; 114 of the 114 references it cites were found in a registry or an index.
Abstract
In the last decade the study of the human brain and muscle energetics underwent a radical change, thanks to the progressive introduction of noninvasive techniques, including near-infrared (NIR) spectroscopy (NIRS). This review summarizes the most recent literature about the principles, techniques, advantages, limitations, and applications of NIRS in exercise physiology and neuroscience. The main NIRS instrumentations and measurable parameters will be reported. NIR light (700-1000 nm) penetrates superficial layers (skin, subcutaneous fat, skull, etc.) and is either absorbed by chromophores (oxy- and deoxyhemoglobin and myoglobin) or scattered within the tissue. NIRS is a noninvasive and relatively low-cost optical technique that is becoming a widely used instrument for measuring tissue O 2 saturation, changes in hemoglobin volume and, indirectly, brain/muscle blood flow and muscle O 2 consumption. Tissue O 2 saturation represents a dynamic balance between O 2 supply and O 2 consumption in the small vessels such as the capillary, arteriolar, and venular bed. The possibility of measuring the cortical activation in response to different stimuli, and the changes in the cortical cytochrome oxidase redox state upon O 2 delivery changes, will also be mentioned. Key words: tissue oximetry, oxidative metabolism, optical imaging, blood flow, oxygen consumption, exercise physiology
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These values are in a large part representative of tissue capillaries, arterioles, and venules because, in larger blood vessels, NIR light is fully absorbed by the high hemoglobin concentration. 4”
From Performance comparison of the MOXY and PortaMon near-infrared spectroscopy muscle oximeters at rest and during exercise (2018) · cites this paper as [4]
In the citing paper
“Furthermore, small differences in ambient and muscular temperature may influence day-today variability, 4 as may slight changes in posture. 38”
From Performance comparison of the MOXY and PortaMon near-infrared spectroscopy muscle oximeters at rest and during exercise (2018) · cites this paper as [4]
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Strangman, G., Culver, J. P., Thompson, J. H., & Boas, D. A. (2002) · NeuroImage · doi:10.1006/nimg.2002.1227 · Cited by 1,415
Recent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
Non-invasive neuroimaging using near-infrared light
Strangman, G., Boas, D. A., & Sutton, J. P. (2002) · Biological Psychiatry · doi:10.1016/s0006-3223(02)01550-0 · Cited by 903
Beyond the Visible???Imaging the Human Brain With Light
Obrig, H., & Villringer, A. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200301000-00001 · Cited by 892
Owen-Reece, H., Smith, M., Elwell, C. E., & Goldstone, J. C. (1999) · British Journal of Anaesthesia · doi:10.1093/bja/82.3.418 · Cited by 688
Spontaneous Low Frequency Oscillations of Cerebral Hemodynamics and Metabolism in Human Adults
Obrig, H., Neufang, M., Wenzel, R., Kohl, M., Steinbrink, J., Einhäupl, K., & Villringer, A. (2000) · NeuroImage · doi:10.1006/nimg.2000.0657 · Cited by 614
Wittenberg, J. B., & Wittenberg, B. A. (2003) · Journal of Experimental Biology · doi:10.1242/jeb.00243 · Cited by 550
Functional near‐infrared optical imaging: Utility and limitations in human brain mapping
Hoshi, Y. (2003) · Psychophysiology · doi:10.1111/1469-8986.00053 · Cited by 532
Recovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528
Research works printed but not linked: 6
- Bangsbo J., 2000, Am. J. Physiol., 279, R899
- McCully K.K., 2000, Exerc. Sport Sci. Rev., 28, 123
- Obrig H., 2003, J. Cereb. Blood Flow Metab., 23, 1, 10.1097/01.wcb.0000043472.45775.29 · DOI · Paper page
- Richardson R.S., 2002, Am. J. Physiol., 283, R1131
- Springett R., 2000, Am. J. Physiol., 279, H2202
- Tran T.K., 1999, Am. J. Physiol., 276, R1682
Cited by
Ferrari, M., & Quaresima, V. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.049 · Cited by 2,274
“Different NIRS instruments with related key features, advantages and disadvantages, and parameters measurable by using different NIRS techniques have been reviewed in detail elsewhere (Ferrari et al., 2004; Wolf et al., 2007) and summarized in Table 2.”
MethodSelf-citationScholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002
Recent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
fNIRS-based brain-computer interfaces: a review
Naseer, N., & Hong, K.-S. (2015) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2015.00003 · Cited by 988
“…et al., 2008; Sardouie and Shamsollahi, 2012), functional magnetic resonance imaging (fMRI) (Weiskopf et al., 2004; LaConte, 2011; van der Heiden et al., 2014), and fNIRS (Ferrari et al., 1985, 2004; Kato et al., 1993; Hu et al., 2013; Bhutta et al., 2014; Rea et al., 2014; Santosa et al., 2014).”
BackgroundLloyd-Fox, S., Blasi, A., & Elwell, C. E. (2010) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2009.07.008 · Cited by 865
Scholkmann, F., Spichtig, S., Muehlemann, T., & Wolf, M. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/5/004 · Cited by 683
The modified Beer–Lambert law revisited
Kocsis, L., Herman, P., & Eke, A. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/5/n02 · Cited by 679
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Progress of near-infrared spectroscopy and topography for brain and muscle clinical applications
Ferrari, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804899 · Cited by 600
Self-citationHerold, F., Wiegel, P., Scholkmann, F., & Müller, N. (2018) · Journal of Clinical Medicine · doi:10.3390/jcm7120466 · Cited by 482
Statistical analysis of fNIRS data: A comprehensive review
Tak, S., & Ye, J. C. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.016 · Cited by 465
Quaresima, V., & Ferrari, M. (2019) · Organizational Research Methods · doi:10.1177/1094428116658959 · Cited by 419
Self-citationNear-infrared spectroscopy: A report from the McDonnell infant methodology consortium
Gervain, J., Mehler, J., Werker, J. F., Nelson, C. A., Csibra, G., Lloyd-Fox, S., Shukla, M., & Aslin, R. N. (2011) · Developmental Cognitive Neuroscience · doi:10.1016/j.dcn.2010.07.004 · Cited by 363
Non-invasive NIR spectroscopy of human brain function during exercise
Perrey, S. (2008) · Methods · doi:10.1016/j.ymeth.2008.04.005 · Cited by 346
Grassi, B., & Quaresima, V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.9.091313 · Cited by 345
“207 The issue has also been discussed in the review by Ferrari et al. 24 Most of the NIRS instruments reported in Table 1 are represented by two to six channels and CW brain oximeters utilized also for physiological/pathophysiological muscle studies.”
BackgroundInfluentialSelf-citationHamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Self-citationRooks, C. R., Thom, N. J., McCully, K. K., & Dishman, R. K. (2010) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2010.06.002 · Cited by 324
Herold, F., Wiegel, P., Scholkmann, F., Thiers, A., Hamacher, D., & Schega, L. (2017) · Neurophotonics · doi:10.1117/1.nph.4.4.041403 · Cited by 314
Cerebral Near-Infrared Spectroscopy in Adults: A Work in Progress
Ghosh, A., Elwell, C., & Smith, M. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31826dd6a6 · Cited by 277
Quaresima, V., Bisconti, S., & Ferrari, M. (2012) · Brain and Language · doi:10.1016/j.bandl.2011.03.009 · Cited by 276
Self-citationStrangman, G. E., Li, Z., & Zhang, Q. (2013) · PLoS ONE · doi:10.1371/journal.pone.0066319 · Cited by 262
Prefrontal cortex oxygenation and neuromuscular responses to exhaustive exercise
Thomas, R., & Stephane, P. (2007) · European Journal of Applied Physiology · doi:10.1007/s00421-007-0568-7 · Cited by 244
Ryan, T. E., Erickson, M. L., Brizendine, J. T., Young, H.-J., & McCully, K. K. (2012) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00319.2012 · Cited by 233
A Review of the Effectiveness of Neuroimaging Modalities for the Detection of Traumatic Brain Injury
Amyot, F., Arciniegas, D. B., Brazaitis, M. P., Curley, K. C., Diaz-Arrastia, R., Gandjbakhche, A., Herscovitch, P., Hinds, S. R., Manley, G. T., Pacifico, A., et al. (2015) · Journal of Neurotrauma · doi:10.1089/neu.2013.3306 · Cited by 230
Social perception in infancy: A near infrared spectroscopy study
Lloyd-Fox, S., Blasi, A., Volein, A., Everdell, N., Elwell, C. E., & Johnson, M. H. (2009) · Child Development · doi:10.1111/j.1467-8624.2009.01312.x · Cited by 217
“However, there is ongoing debate concerning which chromophore changes most closely map the BOLD response (for review, see Ferrari, Mottola, & Quaresima, 2004; Obrig & Villringer, 2003).”
BackgroundKacin, A., & Strazar, K. (2011) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2010.01260.x · Cited by 206
McManus, C. J., Collison, J., & Cooper, C. E. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.1.015007 · Cited by 205
“arterioles, and venules because, in larger blood vessels, NIR light is fully absorbed by the high hemoglobin concentration.(4)”
BackgroundKussman, B. D., Wypij, D., Laussen, P. C., Soul, J. S., Bellinger, D. C., DiNardo, J. A., Robertson, R., Pigula, F. A., Jonas, R. A., & Newburger, J. W. (2010) · Circulation · doi:10.1161/circulationaha.109.902338 · Cited by 195
Hamaoka, T., McCully, K. K., Niwayama, M., & Chance, B. (2011) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2011.0298 · Cited by 186
Jones, S., Chiesa, S. T., Chaturvedi, N., & Hughes, A. D. (2016) · Artery Research · doi:10.1016/j.artres.2016.09.001 · Cited by 184
Spatial heterogeneity of quadriceps muscle deoxygenation kinetics during cycle exercise
Koga, S., Poole, D. C., Ferreira, L. F., Whipp, B. J., Kondo, N., Saitoh, T., Ohmae, E., & Barstow, T. J. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00627.2007 · Cited by 184
Plichta, M. M., Gerdes, A. B. M., Alpers, G. W., Harnisch, W., Brill, S. M., Wieser, M. J., & Fallgatter, A. J. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.01.011 · Cited by 183
Düking, P., Hotho, A., Holmberg, H.-C., Fuss, F. K., & Sperlich, B. (2016) · Frontiers in Physiology · doi:10.3389/fphys.2016.00071 · Cited by 181
Influence of cerebral and muscle oxygenation on repeated-sprint ability
Smith, K. J., & Billaut, F. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1444-4 · Cited by 179
Teo, W.-P., Muthalib, M., Yamin, S., Hendy, A. M., Bramstedt, K., Kotsopoulos, E., Perrey, S., & Ayaz, H. (2016) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2016.00284 · Cited by 175
Blood Flow Restriction Enhances Post–Resistance Exercise Angiogenic Gene Expression
LARKIN, K. A., MACNEIL, R. G., DIRAIN, M., SANDESARA, B., MANINI, T. M., & BUFORD, T. W. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182625928 · Cited by 169
Scalp and skull influence on near infrared photon propagation in the Colin27 brain template
Strangman, G. E., Zhang, Q., & Li, Z. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.090 · Cited by 168
Lucas, S. J. E., Ainslie, P. N., Murrell, C. J., Thomas, K. N., Franz, E. A., & Cotter, J. D. (2012) · Experimental Gerontology · doi:10.1016/j.exger.2011.12.002 · Cited by 162
Kaufman, J., Almodovar, M. C., Zuk, J., & Friesen, R. H. (2008) · Pediatric Critical Care Medicine · doi:10.1097/01.pcc.0000298640.47574.da · Cited by 161
Functional photoacoustic imaging: from nano- and micro- to macro-scale
Park, B., Oh, D., Kim, J., & Kim, C. (2023) · Nano Convergence · doi:10.1186/s40580-023-00377-3 · Cited by 159
Respiratory muscle unloading improves leg muscle oxygenation during exercise in patients with COPD
Borghi-Silva, A., Oliveira, C. C., Carrascosa, C., Maia, J., Berton, D. C., Queiroga, F., Ferreira, E. M., Almeida, D. R., Nery, L. E., & Neder, J. A. (2008) · Thorax · doi:10.1136/thx.2007.090167 · Cited by 156
“[10,17] Although this technique is not able to differentiate between the signal attenuation due to Hb and myoglobin, this confounding factor has been estimated as 10% of the whole Hb signal,[10] a non-critical issue in this withinsubject study.”
Backgroundvan Genderen, M. E., Lima, A. A. P., Akkerhuis, K. M., Bakker, J., & van Bommel, J. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e31825333b2 · Cited by 155
Dietary nitrate improves muscle but not cerebral oxygenation status during exercise in hypoxia
Masschelein, E., Van Thienen, R., Wang, X., Van Schepdael, A., Thomis, M., & Hespel, P. (2012) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01253.2011 · Cited by 152
Joseph, D. K., Huppert, T. J., Franceschini, M. A., & Boas, D. A. (2006) · Applied Optics · doi:10.1364/ao.45.008142 · Cited by 152
Optical imaging of infants' neurocognitive development: Recent advances and perspectives
Minagawa‐Kawai, Y., Mori, K., Hebden, J. C., & Dupoux, E. (2008) · Developmental Neurobiology · doi:10.1002/dneu.20618 · Cited by 151
Muscle Oxygenation Trends During Dynamic Exercise Measured by Near Infrared Spectroscopy
Bhambhani, Y. N. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-033 · Cited by 149
The use of the Henyey–Greenstein phase function in Monte Carlo simulations in biomedical optics
Binzoni, T., Leung, T. S., Gandjbakhche, A., Rüfenacht, D., & Delpy, D. T. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/17/n04 · Cited by 145
A Machine Learning Approach for the Identification of a Biomarker of Human Pain using fNIRS
Rojas, R. F., Huang, X., & Ou, K. (2019) · Scientific Reports · doi:10.1038/s41598-019-42098-w · Cited by 144
Paradis‐Deschênes, P., Joanisse, D. R., & Billaut, F. (2016) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2015-0561 · Cited by 141
Kahya, M., Moon, S., Ranchet, M., Vukas, R. R., Lyons, K. E., Pahwa, R., Akinwuntan, A., & Devos, H. (2019) · Experimental Gerontology · doi:10.1016/j.exger.2019.110756 · Cited by 137
Haemoglobin oxygen saturation as a biomarker: the problem and a solution
Boas, D. A., & Franceschini, M. A. (2011) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2011.0250 · Cited by 135
Cerebral Oxygen Saturation-Time Threshold for Hypoxic-Ischemic Injury in Piglets
Kurth, C. D., McCann, J., Wu, J., Miles, L., & Loepke, A. W. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318196ac8e · Cited by 133
Glass‐Crystallized Luminescence Translucent Ceramics toward High‐Performance Broadband NIR LEDs
Zheng, G., Xiao, W., Wu, J., Liu, X., Masai, H., & Qiu, J. (2022) · Advanced Science · doi:10.1002/advs.202105713 · Cited by 124
Romero‐Moraleda, B., González‐García, J., Cuéllar-Rayo, Á., Balsalobre‐Fernández, C., Muñoz‐García, D., & Morencos, E. (2019) · Europe PMC (PubMed Central) · Cited by 122
Wyser, D., Mattille, M., Wolf, M., Lambercy, O., Scholkmann, F., & Gassert, R. (2020) · Neurophotonics · doi:10.1117/1.nph.7.3.035011 · Cited by 120
Grassi, B., Marzorati, M., Lanfranconi, F., Ferri, A., Longaretti, M., Stucchi, A., Vago, P., Marconi, C., & Morandi, L. (2007) · Muscle & Nerve · doi:10.1002/mus.20708 · Cited by 119
Pereira, M., Gomes, P. S. C., & BHAMBHANI, Y. N. (2007) · Sports Medicine · doi:10.2165/00007256-200737070-00005 · Cited by 118
Near Infrared Brain and Muscle Oximetry: From the Discovery to Current Applications
Ferrari, M., & Quaresima, V. (2012) · Journal of Near Infrared Spectroscopy · doi:10.1255/jnirs.973 · Cited by 116
Self-citationIntraoperative cerebral oxygenation, oxidative injury, and delirium following cardiac surgery
Lopez, M. G., Pandharipande, P. P., Morse, J. L., Shotwell, M. S., Milne, G. L., Pretorius, M., Shaw, A., Roberts, L. J., & Billings, F. T. (2016) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2016.12.039 · Cited by 116
Biazon, T. M. P. D. C., Ugrinowitsch, C., Soligon, S. D., de Oliveira, R. M., Bergamasco, J. G. A., Borghi‐Silva, A., & Libardi, C. A. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.00446 · Cited by 114
Kelly, J., Vanhatalo, A., Bailey, S. J., Wylie, L. J., Tucker, C., List, S., Winyard, P. G., & Jones, A. M. (2014) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00068.2014 · Cited by 113
“The trend for an improved TOI with BR supplementation indicates better muscle oxygenation (24), which may have been responsible for the speeding of the V̇O2 kinetics observed in hypoxia.”
BackgroundWhole-Body Vibration and Blood Flow and Muscle Oxygenation: A Meta-Analysis
Games, K. E., Sefton, J. M., & Wilson, A. E. (2015) · Journal of Athletic Training · doi:10.4085/1062-6050-50.2.09 · Cited by 112
Photonic textiles for pulse oximetry
Rothmaier, M., Selm, B., Spichtig, S., Haensse, D., & Wolf, M. (2008) · Optics Express · doi:10.1364/oe.16.012973 · Cited by 111
Biceps brachii myoelectric and oxygenation changes during static and sinusoidal isometric exercises
Felici, F., Quaresima, V., Fattorini, L., Sbriccoli, P., Filligoi, G. C., & Ferrari, M. (2007) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2007.07.010 · Cited by 110
Self-citationAge‐related microvascular dysfunction: novel insight from near‐infrared spectroscopy
Rosenberry, R., Munson, M., Chung, S., Samuel, T. J., Patik, J. C., Tucker, W. J., Haykowsky, M. J., & Nelson, M. D. (2017) · Experimental Physiology · doi:10.1113/ep086639 · Cited by 109
Chiappa, G. R., Borghi-Silva, A., Ferreira, L. F., Carrascosa, C., Oliveira, C. C., Maia, J., Gimenes, A. C., Queiroga, F., Berton, D., Ferreira, E. M. V., et al. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01364.2007 · Cited by 108
High-resolution functional photoacoustic monitoring of vascular dynamics in human fingers
Ahn, J., Kim, J. Y., Choi, W., & Kim, C. (2021) · Photoacoustics · doi:10.1016/j.pacs.2021.100282 · Cited by 108
Davies, R. C., Eston, R. G., Poole, D. C., Rowlands, A. V., DiMenna, F. J., Wilkerson, D. P., Twist, C., & JONES, A. M. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.90743.2008 · Cited by 102
Tew, G. A., Ruddock, A. D., & Saxton, J. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1596-2 · Cited by 101
Millet, G. Y., Muthalib, M., Jubeau, M., Laursen, P. B., & Nosaka, K. (2012) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00804.2011 · Cited by 100
Berger, A., Horst, F., Müller, S., Steinberg, F., & Doppelmayr, M. M. (2019) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2019.00172 · Cited by 99
Tsuzuki, D., Cai, D., Dan, H., Kyutoku, Y., Fujita, A., Watanabe, E., & Dan, I. (2011) · Neuroscience Research · doi:10.1016/j.neures.2011.10.008 · Cited by 98
Borghi-Silva, A., Carrascosa, C., Oliveira, C. C., Barroco, A. C., Berton, D. C., Vilaça, D., Lira-Filho, E. B., Ribeiro, D., Nery, L. E., & Neder, J. A. (2008) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.91520.2007 · Cited by 97
Tempest, G. D., Eston, R. G., & Parfitt, G. (2014) · PLoS ONE · doi:10.1371/journal.pone.0095924 · Cited by 95
Non-invasive Techniques for Muscle Fatigue Monitoring: A Comprehensive Survey
Li, N., Zhou, R., Krishna, B., Pradhan, A., Lee, H., He, J., & Jiang, N. (2024) · ACM Computing Surveys · doi:10.1145/3648679 · Cited by 95
Vernieri, F., Tibuzzi, F., Pasqualetti, P., Altamura, C., Palazzo, P., Pm, R., & Silvestrini, M. (2008) · Cephalalgia · doi:10.1111/j.1468-2982.2008.01579.x · Cited by 95
Guo, W., Sheng, X., Liu, H., & Zhu, X. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2459067 · Cited by 94
Influence of Postexercise Cooling on Muscle Oxygenation and Blood Volume Changes
IHSAN, M., WATSON, G., LIPSKI, M., & ABBISS, C. R. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31827e13a2 · Cited by 93
Comparing fNIRS signal qualities between approaches with and without short channels
Zhou, X., Sobczak, G. G., McKay, C. M., & Litovsky, R. Y. (2020) · PLoS ONE · doi:10.1371/journal.pone.0244186 · Cited by 93
Koga, S., Poole, D. C., Fukuoka, Y., Ferreira, L. F., Kondo, N., Ohmae, E., & Barstow, T. J. (2011) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00101.2011 · Cited by 92
Braukmann, R., Lloyd‐Fox, S., Blasi, A., Johnson, M. H., Bekkering, H., Buitelaar, J. K., & Hunnius, S. (2017) · European Journal of Neuroscience · doi:10.1111/ejn.13751 · Cited by 92
Hamaoka, T., & McCully, K. K. (2019) · The Journal of Physiological Sciences · doi:10.1007/s12576-019-00697-2 · Cited by 92
A Model of Brain Circulation and Metabolism: NIRS Signal Changes during Physiological Challenges
Banaji, M., Mallet, A., Elwell, C. E., Nicholls, P., & Cooper, C. E. (2008) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1000212 · Cited by 91
The Isometric Torque at Which Knee-Extensor Muscle Reoxygenation Stops
DE RUITER, C. J., GOUDSMIT, J. F. A., VAN TRICHT, J. A., & DE HAAN, A. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31802dd3cc · Cited by 91
Factors contributing to lower metabolic demand of eccentric compared with concentric cycling
Peñailillo, L., Blazevich, A. J., & Nosaka, K. (2017) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00536.2016 · Cited by 91
Bibliometric evaluation of 2000–2019 publications on functional near-infrared spectroscopy
Yan, W., Zheng, K., Weng, L., Chen, C., Kiartivich, S., Jiang, X., Su, X., Wang, Y., & Wang, X. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117121 · Cited by 91
Ferreira, L. F., Hueber, D. M., & Barstow, T. J. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00920.2005 · Cited by 90
Sex-Specific Impact of Ischemic Preconditioning on Tissue Oxygenation and Maximal Concentric Force
Paradis‐Deschênes, P., Joanisse, D. R., & Billaut, F. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2016.00674 · Cited by 89
Uysal, S., Lin, H., Trinh, M. A., Park, C., & Reich, D. L. (2019) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2019.03.036 · Cited by 88
Gesture recognition for transhumeral prosthesis control using EMG and NIR
Nsugbe, E., Phillips, C., Fraser, M., & McIntosh, J. (2020) · IET Cyber-Systems and Robotics · doi:10.1049/iet-csr.2020.0008 · Cited by 88
Tunable Spinel Structure Phosphors: Dynamic Change in Near‐Infrared Windows and Their Applications
Huang, W., Chen, K., Huang, M., & Liu, R. (2023) · Advanced Optical Materials · doi:10.1002/adom.202301166 · Cited by 88
Hu, X.-S., Hong, K.-S., & Ge, S. S. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.1.017003 · Cited by 86
Miyazawa, T., Horiuchi, M., Komine, H., Sugawara, J., Fadel, P. J., & Ogoh, S. (2013) · European Journal of Applied Physiology · doi:10.1007/s00421-013-2723-7 · Cited by 85
Soller, B. R., Yang, Y., Soyemi, O. O., Ryan, K. L., Rickards, C. A., Walz, J. M., Heard, S. O., & Convertino, V. A. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00600.2007 · Cited by 85
Sensor Technologies to Manage the Physiological Traits of Chronic Pain: A Review
Naranjo-Hernández, D., Reina‐Tosina, J., & Roa, L. M. (2020) · Sensors · doi:10.3390/s20020365 · Cited by 84
Near-Infrared Spectroscopy in Pediatric Congenital Heart Disease
Zaleski, K. L., & Kussman, B. D. (2020) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2019.08.048 · Cited by 84
Tutorial on platform for optical topography analysis tools
Sutoko, S., Sato, H. R., Maki, A., Kiguchi, M., Hirabayashi, Y., Atsumori, H., Obata, A. N., Funane, T., & Katura, T. (2016) · Neurophotonics · doi:10.1117/1.nph.3.1.010801 · Cited by 84
Recent Advances in Application of Cerebral Oximetry in Adult Cardiovascular Surgery
Fischer, G. W. (2008) · Seminars in Cardiothoracic and Vascular Anesthesia · doi:10.1177/1089253208316443 · Cited by 84
Skeletal Muscle Metabolism in Endurance Athletes with Near-Infrared Spectroscopy
BRIZENDINE, J. T., RYAN, T. E., LARSON, R. D., & McCULLY, K. K. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31827e0eb6 · Cited by 83
Lange, F., Dunne, L., Hale, L. L., & Tachtsidis, I. (2018) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2018.2833205 · Cited by 83
Metadata
- Authors
- Ferrari, M., Mottola, L., & Quaresima, V.
- Affiliations
- University of L'Aquila (IT)
- Casa Sollievo della Sofferenza (IT)
- Kyoto University (JP)
- Venue
- Canadian Journal of Applied Physiology
- Publisher
- Canadian Science Publishing
- Published
- 2004-08-01
- Volume
- 29
- Issue
- 4
- Pages
- 463-487
- ISSN
- 1066-7814 (ISSN-L)
- OpenAlex
- W2130603606
- Cited by
- 997
- References
- 114
- Citations by year
- 2026: 35 · 2025: 51 · 2024: 44 · 2023: 58 · 2022: 53 · 2021: 46 · 2020: 53 · 2019: 55 · 2018: 54 · 2017: 63 · 2016: 48 · 2015: 52 · 2014: 36 · 2013: 56 · 2012: 68
- FWCI
- 4.61
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.nrcresearchpress.com/page/about/CorporateTextAndDataMining (tdm)
- Locations
- Canadian Journal of Applied Physiology (publishedVersion)
- PubMed (publishedVersion)
- Archivio Istituzionale della Ricerca - Università degli Studi dell Aquila (submittedVersion)
- Funders
- U.S. Food and Drug Administration
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Keywords
- near-infrared spectroscopy, tissue oxygen saturation, hemoglobin, myoglobin, muscle oxygen consumption, cerebral blood flow, brain energy metabolism, cortical activation, cytochrome c oxidase, light scattering, exercise physiology, non-invasive optical measurement
- MeSH terms
- Blood Volume, Cerebral Cortex, Cerebrovascular Circulation, Humans, Oximetry, Oxygen Consumption, Regional Blood Flow, Muscle, Skeletal, Spectroscopy, Near-Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.