Urine specific gravity in exercisers prior to physical training
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Urine specific gravity (USG) is used as an index of hydration status. Many studies have used USG to estimate pre-exercise hydration in athletes. However, very little is known about the pre-exercise hydration status of recreational exercisers. The purpose of the present study was to measure the pre-exercise USG in a large sample of recreational exercisers who attended 2 different fitness centers in the United States. In addition, we wanted to determine if factors such as time of day, geographic location, and gender influenced USG. We tested 166 subjects in Chicago and 163 subjects in Los Angeles. Subjects completed a survey on their typical training regimen and fluid-replacement habits, and thereafter voided and delivered a urine sample to the investigators prior to beginning exercise. Samples were measured on site for USG using a hand-held refractometer. The mean (SD) USG was 1.018 (± 0.007) for all subjects. Males had a higher average USG (1.020 ± 0.007) when compared with females (1.017 ± 0.008; p = 0.001). Despite differences in climate, no difference in mean USG occurred based on location or time of day. Based on standards used for athletes (USG >= 1.020), 46% of the exercisers were likely to be dehydrated.Key words: dehydration, exercise, hydration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Influence of graded dehydration on hyperthermia and cardiovascular drift during exercise
Montain, S. J., & Coyle, E. F. (1992) · Journal of Applied Physiology · doi:10.1152/jappl.1992.73.4.1340 · Cited by 769 · cited 3×
“When dehydration exists immediately before exercise, the rate of increase in core temperature during exercise is more rapid, sweat rate is lower, and heart rate is higher than when one exercises in a euhydrated state (Montain and Coyle 1992b; Nadel 1988; Sherman and Lamb 1988).”
BackgroundCasa, D. J., Clarkson, P. M., & Roberts, W. O. (2005) · Current Sports Medicine Reports · doi:10.1097/01.csmr.0000306194.67241.76 · Cited by 236 · cited 3×
“Ideally, the first void of the morning would be obtained for this purpose (Food and Nutrition Board 2004; Casa et al. 2005).”
BackgroundMethodPlasma Hypertonicity: Another Marker of Frailty?
Stookey, J. D., Purser, J. L., Pieper, C. F., & Cohen, H. J. (2004) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2004.52361.x · Cited by 80
Effect of hypohydration on gastric emptying and intestinal absorption during exercise
Ryan, A. J., Lambert, G. P., Shi, X., Chang, R. T., Summers, R. W., & Gisolfi, C. V. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.84.5.1581 · Cited by 66
Cited by
Effects of acute exercise on appetite hormones and ad libitum energy intake in men and women
Hagobian, T. A., Yamashiro, M., Hinkel-Lipsker, J., Streder, K., Evero, N., & Hackney, T. (2013) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2012-0104 · Cited by 83
Bongiovanni, T., Tinsley, G., Martera, G., Orlandi, C., Genovesi, F., Puleo, G., Rossi, A., & Trecroci, A. (2022) · European Journal of Investigation in Health, Psychology and Education · doi:10.3390/ejihpe12080064 · Cited by 11
Metadata
- Authors
- Stover, E. A., Petrie, H. J., Passe, D., Horswill, C. A., Murray, B., & Wildman, R.
- Venue
- Applied Physiology, Nutrition, and Metabolism
- Publisher
- Canadian Science Publishing
- Published
- 2006-06-01
- Volume
- 31
- Issue
- 3
- Pages
- 320-327
- ISSN
- 1715-5312 (ISSN-L)
- 1715-5320
- OpenAlex
- W2132364765
- Cited by
- 65
- References
- 4
- FWCI
- 0.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.