Validation of the Kenz Lifecorder EX and ActiGraph GT1M accelerometers for walking and running in adults
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Accelerometer-based activity monitors are commonly used by researchers and clinicians to assess physical activity. Recently, the Kenz Lifecorder EX (KL) and ActiGraph GT1M (AG) accelerometers have been made commercially available, but there is limited research on the validity of these devices. Therefore, we sought to validate step count, activity energy expenditure (EE), and total EE output from the KL and AG during treadmill walking and running. Ten male and 10 female participants performed 10 min treadmill walking and running trials, at speeds of 54, 80, 107, 134, 161, and 188 m·min–1. Step counts were hand tallied by 2 observers, and indirect calorimetry was used to validate the accelerometers’ estimates of EE. AG total EE was calculated using the Freedson equation. Analysis of variance (ANOVA) and Pearson’s correlations were used to analyze the data. At the slowest walking speed, the AG and KL counted 64% ± 15% and 92% ± 6% of the observed steps, respectively. At all other treadmill speeds, both activity monitors undercounted, compared with observed steps, by ≤3%. The KL underestimated activity EE at faster running speeds (p < 0.01), overestimated total EE at some walking speeds, and underestimated total EE at some running speeds (p < 0.01). The Freedson equation inaccurately measured total EE at most walking and running speeds. The KL and the AG are moderately priced accelerometers that provide researchers and clinicians with accurate estimates of step counts and activity EE at most walking and running speeds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prevalence of obesity, diabetes, and obesity-related health risk factors, 2001
Mokdad, A. H., Ford, E. S., Bowman, B. A., Dietz, W. H., Vinicor, F., Bales, V. S., & Marks, J. S. (2003) · JAMA · doi:10.1001/jama.289.1.76 · Cited by 5,866 · cited 1×
“It has been established that excess weight and obesity are associated with a greater risk of developing diabetes, high blood pressure, high cholesterol, asthma, arthritis, and other health conditions (Mokdad et al. 2003).”
BackgroundCalibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
Validity of 10 Electronic Pedometers for Measuring Steps, Distance, and Energy Cost
CROUTER, S. E., SCHNEIDER, P. L., KARABULUT, M., & BASSETT, D. R. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000078932.61440.a2 · Cited by 899
Estimating energy expenditure using accelerometers
Crouter, S. E., Churilla, J. R., & Bassett, D. R. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0307-5 · Cited by 366
Promoting and maintaining physical activity in people with type 2 diabetes
Kirk, A. F., Mutrie, N., MacIntyre, P. D., & Fisher, M. B. (2004) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2004.07.009 · Cited by 131 · cited 1×
“Over the past decade, more researchers and clinicians are selecting activity monitors, specifically accelerometers, to demonstrate the efficacy of physical activity interventions (Kirk et al. 2004; Matthews et al. 2007; Paschali et al. 2005).”
BackgroundComparison of two Actigraph models for assessing free-living physical activity in Indian adolescents
Corder, K., Brage, S., Ramachandran, A., Snehalatha, C., Wareham, N., & Ekelund, U. (2007) · Journal of Sports Sciences · doi:10.1080/02640410701283841 · Cited by 120 · cited 1×
“For instance, Corder et al. (2007) reported that the AG-GT1M underestimated activity count min–1, compared with the AG-7164, when used in free-living conditions.”
MethodAccelerometer feedback to promote physical activity in adults with type 2 diabetes: a pilot study
Paschali, A. A., Kalantzi-Azizi, A., Goodrick, G. K., Papadatou, D., & Balasubramanyam, A. (2005) · Perceptual and Motor Skills · doi:10.2466/pms.100.1.61-68 · Cited by 40 · cited 1×
“Over the past decade, more researchers and clinicians are selecting activity monitors, specifically accelerometers, to demonstrate the efficacy of physical activity interventions (Kirk et al. 2004; Matthews et al. 2007; Paschali et al. 2005).”
Background
Cited by
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
“The majority of articles compared activity monitor determined energy expenditure with DLW [73, 77, 80, 96, 105, 274, 275, 277, 278, 280, 281, 285, 292, 293, 295, 296, 300, 303–305, 311, 313, 317, 323], while activity monitor determined steps [119, 271, 283, 287, 289, 298, 299, 306, 307, 314, 315, 318], distance travel…”
Van Remoortel, H., Raste, Y., Louvaris, Z., Giavedoni, S., Burtin, C., Langer, D., Wilson, F., Rabinovich, R., Vogiatzis, I., Hopkinson, N. S., et al. (2012) · PLoS ONE · doi:10.1371/journal.pone.0039198 · Cited by 323
Validation of the Fitbit One activity monitor device during treadmill walking
Takacs, J., Pollock, C. L., Guenther, J. R., Bahar, M., Napier, C., & Hunt, M. A. (2014) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2013.10.241 · Cited by 321
Validity of activity monitors in health and chronic disease: a systematic review
Van Remoortel, H., Giavedoni, S., Raste, Y., Burtin, C., Louvaris, Z., Gimeno-Santos, E., Langer, D., Glendenning, A., Hopkinson, N. S., Vogiatzis, I., et al. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-84 · Cited by 277
Metadata
- Authors
- Abel, M. G., Hannon, J. C., Sell, K., Lillie, T., Conlin, G., & Anderson, D.
- Venue
- Applied Physiology, Nutrition, and Metabolism
- Publisher
- Canadian Science Publishing
- Published
- 2008-12
- Volume
- 33
- Issue
- 6
- Pages
- 1155-1164
- ISSN
- 1715-5312 (ISSN-L)
- 1715-5320
- OpenAlex
- W2166402494
- Cited by
- 134
- References
- 7
- FWCI
- 3.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.