Reliability and Validity of a Portable Metabolic Measurement System
The DOI matches its Crossref record.
Abstract
The purpose of this study was to assess the reliability and validity of a portable metabolic system (TEEM 100) during submaximal and maximal [Formula: see text] exercise using a computer-based metabolic system as the reference system (REF). Between repeated trials of submaximal exercise at three constant loads, differences in ventilation [Formula: see text] and oxygen consumption [Formula: see text] were 0.2 ± 4.9 L∙min−1 and 0.03 ± 0.10 L∙min−1 for REF, and 1.9 ± 0.7 L∙min−1 and 0.00 ± 0.17 L∙min−1 for TEEM 100. Pooled intraclass reliability coefficients for [Formula: see text] and [Formula: see text] calculated from the repeated submaximal trials were r =.89 and r =.94 for REF, and r =.86 and r =.94 for the TEEM 100. Respiratory exchange ratio (RER) measured by the TEEM 100 was significantly higher (p =.01) at only the lowest workload. At [Formula: see text], the TEEM 100 recorded significantly higher values for FeO 2 (p =.01) and RER (p <.001). These results suggest that the TEEM 100 provides reliable and valid measurements of [Formula: see text] during submaximal and maximal exercise. Key words: oxygen consumption, indirect calorimetry, portable analysis, exercise, metabolism
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Validity of accelerometry for the assessment of moderate intensity physical activity in the field
HENDELMAN, D., MILLER, K., BAGGETT, C., DEBOLD, E., & FREEDSON, P. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00002 · Cited by 516
Self-citationOhkawara, K., Oshima, Y., Hikihara, Y., Ishikawa-Takata, K., Tabata, I., & Tanaka, S. (2011) · British Journal of Nutrition · doi:10.1017/s0007114510005441 · Cited by 458
Parasympathetic reactivation after repeated sprint exercise
Buchheit, M., Laursen, P. B., & Ahmaidi, S. (2007) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00062.2007 · Cited by 290
Accuracy and reliability of a Cosmed K4b2 portable gas analysis system
Duffield, R., Dawson, B., Pinnington, H. C., & Wong, P. (2004) · Journal of Science and Medicine in Sport · doi:10.1016/s1440-2440(04)80039-2 · Cited by 246
Wilks, D. C., Besson, H., Lindroos, A. K., & Ekelund, U. (2011) · Obesity Reviews · doi:10.1111/j.1467-789x.2010.00775.x · Cited by 142
Metadata
- Authors
- Melanson, E. L., Freedson, P. S., Hendelman, D., & Debold, E.
- Venue
- Canadian Journal of Applied Physiology
- Publisher
- Canadian Science Publishing
- Published
- 1996-04-01
- Volume
- 21
- Issue
- 2
- Pages
- 109-119
- ISSN
- 1066-7814 (ISSN-L)
- OpenAlex
- W2083633008
- Cited by
- 39
- References
- 0
- FWCI
- 3.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reliability and Validity of a Portable Metabolic Measurement System. https://app.cochat.ai/papers/10.1139/h96-010
- The paper
- Melanson, E. L., Freedson, P. S., Hendelman, D., & Debold, E. (1996). Reliability and Validity of a Portable Metabolic Measurement System. Canadian Journal of Applied Physiology. https://doi.org/10.1139/h96-010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.