Bond strength in concrete filled built-up steel tube columns with tab stiffeners
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Apart from strength and ductility, adequate bond between steel and concrete at the interface is important in concrete filled steel tube (CFST) columns to ensure a composite action. One way of improving the bond strength of a CFST column is introducing internal stiffeners. This paper presents an experimental investigation into the bond strength of a CFST column with tab stiffeners by conducting a push out test. Twenty-one square specimens of sides 200 mm × 200 mm, fabricated from 2 mm thick mild steel sheeting were tested in two series. The first series considered the variation in the tab spacing along the stiffeners, namely 75, 100, 150, and 300 mm, while in the second series, the concrete cube compressive strengths were 36, 40, and 50 MPa. The bond strength at the concrete–steel interface was found to increase with decreasing tab spacing. In-filling the tubes with higher strength concrete had also resulted in an increase in the bond strength by up to an average of 40%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tao, Z., Han, L.-H., & Wang, D.-Y. (2008) · Thin-Walled Structures · doi:10.1016/j.tws.2008.01.007 · Cited by 240
Xu, C., Chengkui, H., Decheng, J., & Yuancheng, S. (2009) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2007.10.021 · Cited by 130
Mouli, M., & Khelafi, H. (2007) · Engineering Structures · doi:10.1016/j.engstruct.2006.10.003 · Cited by 79
Cited by
Bond behavior in concrete-filled steel tubes
Tao, Z., Song, T.-Y., Uy, B., & Han, L.-H. (2016) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2015.12.030 · Cited by 296
Stiffened concrete-filled steel tubes: A systematic review
Alatshan, F., Osman, S. A., Hamid, R., & Mashiri, F. (2020) · Thin-Walled Structures · doi:10.1016/j.tws.2019.106590 · Cited by 129
Bond behaviour of concrete-filled steel tubes at the Arctic low temperatures
Yan, J.-B., Xie, W., Zhang, L., & Lin, X.-C. (2019) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2019.03.168 · Cited by 90
Bond behavior of concrete-filled steel tubes at elevated temperatures
Song, T.-Y., Tao, Z., Han, L.-H., & Uy, B. (2017) · Journal of Structural Engineering · doi:10.1061/(asce)st.1943-541x.0001890 · Cited by 75
Push-out tests and bond strength of rectangular CFST columns
Qu, X., Chen, Z., Nethercot, D. A., Gardner, L., & Theofanous, M. (2015) · Steel and Composite Structures · doi:10.12989/scs.2015.19.1.021 · Cited by 49
“…connectors (ShakirKhalil 1993b), threaded bars (Shakir-Khalil and Hassan 1994), self-taping screws (Kilpatrick and Rangan 1999) and tab stiffeners (Petrus et al. 2011), is crucial for the satisfactory performance of CFST members particularly in the vicinity of the connections where the bond…”
Background
Metadata
- Authors
- Petrus, C., Abdul Hamid, H., Ibrahim, A., & Nyuin, J. D.
- Venue
- Canadian Journal of Civil Engineering
- Publisher
- Canadian Science Publishing
- Published
- 2011-06
- Volume
- 38
- Issue
- 6
- Pages
- 627-637
- ISSN
- 0315-1468 (ISSN-L)
- 1208-6029
- OpenAlex
- W1953118632
- Cited by
- 31
- References
- 3
- FWCI
- 1.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.