Cited by 90Structural Load-Bearing AnalysisStructural Behavior of Reinforced ConcreteFire effects on concrete materials

Bond behaviour of concrete-filled steel tubes at the Arctic low temperatures

Open access
Yan, Jia-Bao, Xie, Wenjun, Zhang, Lingxin, Lin, Xu-Chuan·2019·Construction and Building Materials

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.conbuildmat.2019.03.168

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Part of this paper’s reference list could not be split into single entries.

Flagged first, then by citations

Research works printed but not linked: 6

  1. [9][9] Morishita Y, Tomii M, Yoshimura K. Experimental studies on bond strength in concrete filled circular steel tubular columns subjected to axial loads. Transactions of Japan Concrete Institute; 1979. p. 351-8. -
  2. [10][10] Tomii M, Yoshimura K, Morishita Y. A method of improving bond strength in between steel tube and concrete core cast in circular steel tubular columns. Transactions of Japan Concrete Institute, 2; 1980. p. 319-26. -
  3. [11][11] Shakir-Khalil H, Pushout strength of concrete-filled steel hollow sections. Structural Engineer 1993; 71 (13): 230-243. -
  4. [17][17] Shakir-Khalil H, Hassan NKA. Push-Out Resistance of concrete-Filled Tubes. Proceedings of the Sixth International Symposium on Tubular Structures, Melbourne, Australia, 14-16 December 1994; 285-291. -
  5. [33][33] Xie J, Yan JB. Tests and analysis on thermal expansion behaviour of steel strand used in prestressed concrete structure under low temperatures. International Journal of Concrete Structures and Materials 2018; 12(1): 91-100. -
  6. [34][34] Xue LH, Cai SH. Bond strength at interface of CFST columns, Part II. Building Science 1996; 4: 19-23. (In Chinese). -

Cited by

Sorted by citations

Authors
Yan, J.-B., Xie, W., Zhang, L., & Lin, X.-C.
Affiliations
  • Tianjin University (CN)
  • State Key Laboratory of Mechanical System and Vibration (CN)
Corresponding author
Zhang, Lingxin
Venue
Construction and Building Materials
Publisher
Elsevier BV
Published
2019-06
Volume
210
Pages
118-131
ISSN
0950-0618 (ISSN-L)
OpenAlex
W2925143185
Cited by
90
References
27
Citations by year
2026: 17 · 2025: 22 · 2024: 19 · 2023: 11 · 2022: 10 · 2021: 3 · 2020: 5 · 2019: 3
FWCI
3.93
Type
journal article
Language
en
Open access
Locations
  • Construction and Building Materials (acceptedVersion)
  • HAL (submittedVersion, cc-by-nc)
Funders
  • National Natural Science Foundation of China (51608358, 51678542)
  • Peiyang Scholar Foundation (2019XRX-0026)
Topics
  • Physical Sciences › Engineering › Civil and Structural Engineering › Structural Load-Bearing Analysis
  • Physical Sciences › Engineering › Building and Construction › Structural Behavior of Reinforced Concrete
  • Physical Sciences › Engineering › Civil and Structural Engineering › Fire effects on concrete materials
Keywords
concrete-filled steel tubes, bond strength, low temperature, Arctic conditions, diameter-to-thickness ratio, length-to-diameter ratio, concrete grade, Eurocode 4

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review