Extensive studies have been conducted into the bond behavior in concrete-filled steel tubes (CFST) at ambient temperature. However, the bond behavior of CFST columns subjected to fire is still unclear. A total of 24 push-out tests were conducted to investigate the bond strength of CFST columns at elevated temperatures, 12 reference specimens at ambient temperature, and 16 postfire specimens were also tested for comparison. The main test parameters explored in this test program include: steel type (carbon and stainless steels), concrete type (normal and expansive concretes), cross-section type (circular and square sections), interface type (normal interface, interface with shear studs, and interface with an internal ring), temperature level (20, 200, 400, 600, and 800°C), hold time period of heating (45, 90, 135, and 180 min), and applied axial load during heating. The experimental results indicated that the bond of specimens with normal interface could be completely broken in fire. However, welding internal rings or shear studs onto the inner surface of the steel tube can effectively retain a portion of the bond strength in fire.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Song et al. [24] compared the effects of different steel types, and found that the bond strength of a stainless-steel specimen was usually lower than that of a reference specimen with carbon steel at ambient temperature.”
From Investigation on the bond-slip behavior of recycled aggregate concrete-filled steel tube with studs (2025) · cites this paper as Song et al. [24]
In the citing paper
“The third increase in the bond stress has not been observed in previous studies [8,34,36], which 191 may be due to the different cross-sectional dimensions of the CFSSSTs considered.”
From Bond stress-slip relationship in concrete-filled square stainless steel tubes (2022) · cites this paper as [34]
In the citing paper
“Song et al. [34] studied the bond strength in CFSSTs at elevated temperatures and showed that the bond interface can be broken in fire.”
From Bond stress-slip relationship in concrete-filled square stainless steel tubes (2022) · cites this paper as [34]
In the citing paper
“Therefore, it is understandable that previous studies [8,34,36] 198 adopting much more slender tubes had no strain hardening behavior observed after reaching the ultimate 199 bond stress τu.”
From Bond stress-slip relationship in concrete-filled square stainless steel tubes (2022) · cites this paper as [34]
In the citing paper
“Previous studies [8,34,36] on the bond behavior of square CFSST specimens used seamless tubes with rounded corners and no normal stress concentration was present.”
From Bond stress-slip relationship in concrete-filled square stainless steel tubes (2022) · cites this paper as [34]
Citations
Cites
Steels: Microstructure and properties
Turner, A. (1982) · Journal of Mechanical Working Technology · doi:10.1016/0378-3804(82)90037-7 · Cited by 842
The use of stainless steel in structures
Gardner, L. (2005) · Progress in Structural Engineering and Materials · doi:10.1002/pse.190 · Cited by 496
Steels: Microstructure and Properties - 3rd ed. -
Bhadeshia, H. K. D. H., & Honeycombe, R. W. K. (2006) · Cited by 459
Stress-Strain Curves of Structural and Reinforcing Steels after Exposure to Elevated Temperatures
Tao, Z., Wang, X.-Q., & Uy, B. (2013) · Journal of Materials in Civil Engineering · doi:10.1061/(asce)mt.1943-5533.0000676 · Cited by 425
Self-citationBond behavior in concrete-filled steel tubes
Tao, Z., Song, T.-Y., Uy, B., & Han, L.-H. (2016) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2015.12.030 · Cited by 296
Self-citationDing, J., & Wang, Y. C. (2008) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2007.09.014 · Cited by 187
Post-fire bond between the steel tube and concrete in concrete-filled steel tubular columns
Tao, Z., Han, L.-H., Uy, B., & Chen, X. (2011) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2010.09.006 · Cited by 152
Self-citationConcrete filled steel tube stub columns under combined temperature and loading
Song, T.-Y., Han, L., & Yu, H. (2009) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2009.10.010 · Cited by 134
Self-citationXu, C., Chengkui, H., Decheng, J., & Yuancheng, S. (2009) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2007.10.021 · Cited by 130
Aly, T., Elchalakani, M., Thayalan, P., & Patnaikuni, I. (2010) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2009.08.002 · Cited by 89
Research works printed but not linked: 2
- Jaspart J. P. (1991). “Study of the semi-rigidity of beam-to-column joints and its influence on the resistance and stability of steel buildings.” Ph.D. thesis Liège Univ. Liège Belgium.
- Shakir-Khalil, H. (1993). “Pushout strength of concrete-filled steel hollow sections.” Struct. Eng., 71(13), 230–243.
Cited by
Han, L.-H., Xu, C.-Y., & Tao, Z. (2019) · Journal of Constructional Steel Research · doi:10.1016/j.jcsr.2018.02.038 · Cited by 193
Self-citationStiffened concrete-filled steel tubes: A systematic review
Alatshan, F., Osman, S. A., Hamid, R., & Mashiri, F. (2020) · Thin-Walled Structures · doi:10.1016/j.tws.2019.106590 · Cited by 129
Han, L., Xu, C.-Y., & Hou, C. (2022) · Engineering Structures · doi:10.1016/j.engstruct.2022.114306 · Cited by 103
Self-citationBond behaviour of concrete-filled steel tubes at the Arctic low temperatures
Yan, J.-B., Xie, W., Zhang, L., & Lin, X.-C. (2019) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2019.03.168 · Cited by 90
Li, W., Chen, B., Han, L.-H., & Lam, D. (2020) · Thin-Walled Structures · doi:10.1016/j.tws.2020.106660 · Cited by 66
Self-citation
Metadata
- Authors
- Song, T.-Y., Tao, Z., Han, L.-H., & Uy, B.
- Affiliations
- Beijing University of Technology (CN)
- Western Sydney University (AU)
- Tsinghua University (CN)
- The University of Sydney (AU)
- Corresponding author
- Tao, Zhong
- Venue
- Journal of Structural Engineering
- Published
- 2017-11
- Volume
- 143
- Issue
- 11
- ISSN
- 0733-9445 (ISSN-L)
- 1943-541X
- OpenAlex
- W2749213917
- Cited by
- 75
- References
- 17
- Citations by year
- 2026: 10 · 2025: 15 · 2024: 13 · 2023: 9 · 2022: 12 · 2021: 3 · 2020: 7 · 2019: 4 · 2018: 1 · 2017: 1
- FWCI
- 3.72
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Structural Engineering (publishedVersion)
- Funders
- National Natural Science Foundation of China
- Australian Research Council
- Topics
- Physical Sciences › Engineering › Civil and Structural Engineering › Structural Load-Bearing Analysis
- Physical Sciences › Engineering › Civil and Structural Engineering › Fire effects on concrete materials
- Physical Sciences › Engineering › Building and Construction › Structural Behavior of Reinforced Concrete
- Keywords
- concrete-filled steel tubes, bond strength, high temperature, fire resistance, push-out test, steel-concrete interface, shear studs, internal ring, expansive concrete, carbon steel, stainless steel, axial loading
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bond Behavior of Concrete-Filled Steel Tubes at Elevated Temperatures. https://app.cochat.ai/papers/10.1061/(asce)st.1943-541x.0001890
- The paper
- Song, T.-Y., Tao, Z., Han, L.-H., & Uy, B. (2017). Bond Behavior of Concrete-Filled Steel Tubes at Elevated Temperatures. Journal of Structural Engineering. https://doi.org/10.1061/(asce)st.1943-541x.0001890
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.