Temperature measurement of a single ion in a Penning trap
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Such a dependence of ν z on the axial energy-which is not constant but fluctuating [27]-would render the detection of the electron almost impossible, even at cryogenic temperatures.”
From Theory of the coplanar-waveguide Penning trap (2011) · cites this paper as [27]
In the citing paper
“The measurement of ω z occurs with the axial motion being in thermal equilibrium with the LC resonator, typically at 4 K or eventually even at higher temperatures [23].”
From Single Microwave Photon Detection with a Trapped Electron (2016) · cites this paper as [23]
Citations
Cites
Thermal Agitation of Electricity in Conductors
Johnson, J. B. (1928) · Physical Review · doi:10.1103/physrev.32.97 · Cited by 1,811
Geonium theory: Physics of a single electron or ion in a Penning trap
Brown, L. S., & Gabrielse, G. (1986) · Reviews of Modern Physics · doi:10.1103/revmodphys.58.233 · Cited by 1,367
Die glimmentladung bei niedrigem druck zwischen koaxialen zylindern in einem axialen magnetfeld
Penning, F. M. (1936) · Physica · doi:10.1016/s0031-8914(36)80313-9 · Cited by 383
Principles of the stored ion calorimeter
Wineland, D. J., & Dehmelt, H. G. (1975) · Journal of Applied Physics · doi:10.1063/1.321602 · Cited by 328
Open-endcap Penning traps for high precision experiments
Gabrielse, G., Haarsma, L., & Rolston, S. L. (1989) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(89)85027-x · Cited by 288
Häffner, H., Beier, T., Hermanspahn, N., Kluge, H.-J., Quint, W., Stahl, S., Verdú, J., & Werth, G. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.5308 · Cited by 285
Self-citationElectronicgFactor of Hydrogenlike OxygenO7+16
Verdú, J., Djekić, S., Stahl, S., Valenzuela, T., Vogel, M., Werth, G., Beier, T., Kluge, H.-J., & Quint, W. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.093002 · Cited by 251
Self-citationMode coupling in a Penning trap:π pulses and a classical avoided crossing
Cornell, E. A., Weisskoff, R. M., Boyce, K. R., & Pritchard, D. E. (1990) · Physical Review A · doi:10.1103/physreva.41.312 · Cited by 181
Double Penning trap technique for precise g factor determinations in highly charged ions
Häffner, H., Beier, T., Djekić, S., Hermanspahn, N., Kluge, H.-J., Quint, W., Stahl, S., Verdú, J., Valenzuela, T., & Werth, G. (2003) · The European Physical Journal D · doi:10.1140/epjd/e2003-00012-2 · Cited by 132
Self-citationObservation of the continuous Stern-Gerlach effect on an electron bound in an atomic Ion
Hermanspahn, N., Häffner, H., Kluge, H.-J., Quint, W., Stahl, S., Verdú, J., & Werth, G. (2000) · Physical Review Letters · doi:10.1103/physrevlett.84.427 · Cited by 113
Self-citation
Research works printed but not linked: 1
- F. DiFilippo et al. , Phys. Scripta T 59, 144 (1995)
Cited by
Ion-trap measurements of electric-field noise near surfaces
Brownnutt, M., Kumph, M., Rabl, P., & Blatt, R. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.1419 · Cited by 413
“While temperature measurements have been carried out in Penning traps (Djekic et al., 2004), as well as heating rate measurements for large crystals (Jensen et al., 2004) and – very recently – for single ions (Goodwin et al., 2014), it remains the case that the majority of noise investigations have…”
BackgroundInfluentialBASE – The Baryon Antibaryon Symmetry Experiment
Smorra, C., Blaum, K., Bojtár, L., Borchert, M. J., Franke, K., Higuchi, T., Leefer, N., Nagahama, H., Matsuda, Y., Mooser, A. H., et al. (2015) · The European Physical Journal Special Topics · doi:10.1140/epjst/e2015-02607-4 · Cited by 105
Self-citationStahl, S., Galve, F., Alonso, J., Djekic, S., Quint, W., Valenzuela, T., Verd�, J., Vogel, M., & Werth, G. (2005) · The European Physical Journal D · doi:10.1140/epjd/e2004-00179-x · Cited by 78
Self-citationvon Lindenfels, D., Wiesel, M., Glazov, D. A., Volotka, A. V., Sokolov, M. M., Шабаев, В. М., Plunien, G., Quint, W., Birkl, G., Martin, A., et al. (2013) · Physical Review A · doi:10.1103/physreva.87.023412 · Cited by 74
Self-citationDevlin, J. A., Borchert, M. J., Erlewein, S., Fleck, M., Harrington, J. A., Latacz, B. M., Warncke, J., Wursten, E., Bohman, M., Mooser, A. H., et al. (2021) · Physical Review Letters · doi:10.1103/physrevlett.126.041301 · Cited by 79
“In addition, we determine the noise temperature Tz by measuring the axial energy of the single antiproton in thermal equilibrium with the detection system [34].”
MethodSelf-citation
Metadata
- Authors
- Djekic, S., Alonso, J., Kluge, H.-J., Quint, W., Stahl, S., Valenzuela, T., Verd�, J., Vogel, M., & Werth, G.
- Affiliations
- GSI Helmholtz Centre for Heavy Ion Research (DE)
- Johannes Gutenberg University Mainz (DE)
- Corresponding author
- Vogel, M.
- Venue
- The European Physical Journal D
- Published
- 2004-12
- Volume
- 31
- Issue
- 3
- Pages
- 451-457
- ISSN
- 1434-6060 (ISSN-L)
- 1434-6079
- OpenAlex
- W2003755790
- Cited by
- 40
- References
- 15
- Citations by year
- 2024: 5 · 2021: 2 · 2019: 1 · 2018: 2 · 2017: 1 · 2016: 1 · 2015: 2 · 2014: 3 · 2013: 3 · 2012: 3
- FWCI
- 0.82
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- The European Physical Journal D (publishedVersion)
- Springer Link (Chiba Institute of Technology) (submittedVersion)
- GSI Repository (German Federal Government) (submittedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Molecular Physics
- Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › Particle accelerators and beam dynamics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Dust and Plasma Wave Phenomena
- Keywords
- Penning trap, ion cyclotron frequency, mode coupling, ion storage
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Temperature measurement of a single ion in a Penning trap. https://app.cochat.ai/papers/10.1140/epjd/e2004-00168-1
- The paper
- Djekic, S., Alonso, J., Kluge, H.-J., Quint, W., Stahl, S., Valenzuela, T., Verd�, J., Vogel, M., & Werth, G. (2004). Temperature measurement of a single ion in a Penning trap. The European Physical Journal D. https://doi.org/10.1140/epjd/e2004-00168-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.