Electrocardiogram (ECG) is the electrical activity of the heart indicated by P, Q-R-S and T wave. The minute changes in the amplitude and duration of ECG depicts a particular type of cardiac abnormality. It is very difficult to decipher the hidden information present in this nonlinear and nonstationary signal. An automatic diagnostic system that characterizes cardiac activities in ECG signals would provide more insight into these phenomena thereby revealing important clinical information. Various methods have been proposed to detect cardiac abnormalities in ECG recordings. Application of higher order spectra (HOS) features is a seemingly promising approach because it can capture the nonlinear and dynamic nature of the ECG signals. In this paper, we have automatically classified five types of beats using HOS features (higher order cumulants) using two different approaches. The five types of ECG beats are normal (N), right bundle branch block (RBBB), left bundle branch block (LBBB), atrial premature contraction (APC) and ventricular premature contraction (VPC). In the first approach, cumulant features of segmented ECG signal were used for classification; whereas in the second approach cumulants of discrete wavelet transform (DWT) coefficients were used as features for classifiers. In both approaches, the cumulant features were subjected to data reduction using principal component analysis (PCA) and classified using three layer feed-forward neural network (NN) and least square — support vector machine (LS-SVM) classifiers. In this study, we obtained the highest average accuracy of 94.52%, sensitivity of 98.61% and specificity of 98.41% using first approach with NN classifier. The developed system is ready clinically to run on large datasets.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1142/s0129065713500147

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 188

Metadata

Authors
MARTIS, R. J., ACHARYA, U. R., LIM, C. M., MANDANA, K. M., RAY, A. K., & CHAKRABORTY, C.
Venue
International Journal of Neural Systems
Published
2013-06-09
Volume
23
Issue
04
Pages
1350014
ISSN
  • 0129-0657 (ISSN-L)
  • 1793-6462
OpenAlex
W2045867791
Cited by
188
References
5
FWCI
5.08
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: APPLICATION OF HIGHER ORDER CUMULANT FEATURES FOR CARDIAC HEALTH DIAGNOSIS USING ECG SIGNALS. https://app.cochat.ai/papers/10.1142/s0129065713500147
The paper
MARTIS, R. J., ACHARYA, U. R., LIM, C. M., MANDANA, K. M., RAY, A. K., & CHAKRABORTY, C. (2013). APPLICATION OF HIGHER ORDER CUMULANT FEATURES FOR CARDIAC HEALTH DIAGNOSIS USING ECG SIGNALS. International Journal of Neural Systems. https://doi.org/10.1142/s0129065713500147

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.