The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
APPLICATION OF HIGHER ORDER CUMULANT FEATURES FOR CARDIAC HEALTH DIAGNOSIS USING ECG SIGNALS
Abstract
Electrocardiogram (ECG) is the electrical activity of the heart indicated by P, Q-R-S and T wave. The minute changes in the amplitude and duration of ECG depicts a particular type of cardiac abnormality. It is very difficult to decipher the hidden information present in this nonlinear and nonstationary signal. An automatic diagnostic system that characterizes cardiac activities in ECG signals would provide more insight into these phenomena thereby revealing important clinical information. Various methods have been proposed to detect cardiac abnormalities in ECG recordings. Application of higher order spectra (HOS) features is a seemingly promising approach because it can capture the nonlinear and dynamic nature of the ECG signals. In this paper, we have automatically classified five types of beats using HOS features (higher order cumulants) using two different approaches. The five types of ECG beats are normal (N), right bundle branch block (RBBB), left bundle branch block (LBBB), atrial premature contraction (APC) and ventricular premature contraction (VPC). In the first approach, cumulant features of segmented ECG signal were used for classification; whereas in the second approach cumulants of discrete wavelet transform (DWT) coefficients were used as features for classifiers. In both approaches, the cumulant features were subjected to data reduction using principal component analysis (PCA) and classified using three layer feed-forward neural network (NN) and least square — support vector machine (LS-SVM) classifiers. In this study, we obtained the highest average accuracy of 94.52%, sensitivity of 98.61% and specificity of 98.41% using first approach with NN classifier. The developed system is ready clinically to run on large datasets.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural Networks for Pattern Recognition
Bishop, C. M. (1995) · doi:10.1093/oso/9780198538493.001.0001 · Cited by 12,287
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
WRITING GROUP MEMBERS, Lloyd-Jones, D., Adams, R., Carnethon, M., De Simone, G., Ferguson, T. B., Flegal, K., Ford, E., Furie, K., Go, A., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.191261 · Cited by 3,140
Wavelet transforms and the ECG: a review
Addison, P. S. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/5/r01 · Cited by 908
Stemming the global tsunami of cardiovascular disease
Anand, S. S., & Yusuf, S. (2011) · The Lancet · doi:10.1016/s0140-6736(10)62346-x · Cited by 216
Cited by
Epileptic Seizures Detection Using Deep Learning Techniques: A Review
Shoeibi, A., Khodatars, M., Ghassemi, N., Jafari, M., Moridian, P., Alizadehsani, R., Panahiazar, M., Khozeimeh, F., Zare, A., Hosseini-Nejad, H., et al. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18115780 · Cited by 459
Self-citation
Metadata
- Authors
- MARTIS, R. J., ACHARYA, U. R., LIM, C. M., MANDANA, K. M., RAY, A. K., & CHAKRABORTY, C.
- Venue
- International Journal of Neural Systems
- Publisher
- World Scientific Pub Co Pte Ltd
- Published
- 2013-06-09
- Volume
- 23
- Issue
- 04
- Pages
- 1350014
- ISSN
- 0129-0657 (ISSN-L)
- 1793-6462
- OpenAlex
- W2045867791
- Cited by
- 188
- References
- 5
- FWCI
- 5.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: APPLICATION OF HIGHER ORDER CUMULANT FEATURES FOR CARDIAC HEALTH DIAGNOSIS USING ECG SIGNALS. https://app.cochat.ai/papers/10.1142/s0129065713500147
- The paper
- MARTIS, R. J., ACHARYA, U. R., LIM, C. M., MANDANA, K. M., RAY, A. K., & CHAKRABORTY, C. (2013). APPLICATION OF HIGHER ORDER CUMULANT FEATURES FOR CARDIAC HEALTH DIAGNOSIS USING ECG SIGNALS. International Journal of Neural Systems. https://doi.org/10.1142/s0129065713500147
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.