The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Preparation of iron oxide nanoparticles by laser ablation in DMF under effect of external magnetic field
Abstract
We have studied the effect of applying an external magnetic field on the characteristics of iron oxide (IO) nanoparticles (NPs) synthesized by pulsed laser ablation in dimethylformamide (DMF). The NPs synthesized with and without applying of magnetic field were characterized by Fourier transformation infrared spectroscopy (FT-IR), UV–Vis absorption, scanning electron microscope (SEM), atomic force microscope (AFM), and X-ray diffraction (XRD). SEM results confirmed that the particle size was decreased after applying magnetic field.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Ismael et al. found that TEM images confirm the particle size of iron oxide NPs reduces under the application of a magnetic field.
“Transmission electron microscopy (TEM) images confirm that the particle size reduces under the application of a magnetic field.”
Citations
Cites
Ankamwar, B., Lai, T. C., Huang, J. H., Liu, R. S., Hsiao, M., Chen, C. H., & Hwu, Y. K. (2010) · Nanotechnology · doi:10.1088/0957-4484/21/7/075102 · Cited by 267
Flagged first, then by citations
Research works printed but not linked: 14
- 10.1179/095066004225021882 · DOI
- 10.1016/j.msec.2015.04.047 · DOI
- 10.1021/cr068445e · DOI · Paper page
- Albornoz C., 2006, J. Magn. Magn. Mater., 12, 305
- 10.1016/j.jcrysgro.2004.11.423 · DOI
- 10.1016/j.matlet.2007.02.018 · DOI · Paper page
- Fievet F., 1989, Solid State Ion., 198, 32
- 10.1021/jp109371m · DOI
- 10.2961/jlmn.2008.02.0003 · DOI · Paper page
- 10.1351/PAC-CON-09-10-23 · DOI · Paper page
- 10.1007/BF00665502 · DOI
- Ahmad S., 2014, Can. Chem. Trans., 2, 122
- 10.1016/j.colsurfa.2006.03.010 · DOI
- Al-hddad R., 2014, Unique J. Eng. Adv. Sci., 2, 65
Cited by
Sorted by citations
Subhan, A., Mourad, A.-H. I., & Al-Douri, Y. (2022) · Nanomaterials · doi:10.3390/nano12132144 · Cited by 95
“[173] conducted a study on the influence of a magnetic field on synthesised iron oxide NPs immersed in dimethylformamide.”
Background
Metadata
- Authors
- Ismail, R. A., Sulaiman, G. M., & Abdulrahman, S. A.
- Affiliations
- University of Technology - Iraq (IQ)
- Venue
- International Journal of Modern Physics B
- Publisher
- World Scientific Pub Co Pte Lt
- Published
- 2016-06-30
- Volume
- 30
- Issue
- 17
- Pages
- 1650094
- ISSN
- 0217-9792 (ISSN-L)
- 1793-6578
- OpenAlex
- W2399481972
- Cited by
- 20
- References
- 1
- Citations by year
- 2026: 1 · 2025: 1 · 2023: 3 · 2022: 4 · 2021: 7 · 2020: 1 · 2019: 2 · 2016: 1
- FWCI
- 0.48
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Modern Physics B (publishedVersion)
- Topics
- Physical Sciences › Materials Science › Materials Chemistry › Laser-Ablation Synthesis of Nanoparticles
- Physical Sciences › Materials Science › Materials Chemistry › Nanoparticles: synthesis and applications
- Physical Sciences › Engineering › Biomedical Engineering › Characterization and Applications of Magnetic Nanoparticles
- Keywords
- iron oxide nanoparticles, pulsed laser ablation, dimethylformamide, external magnetic field, particle size reduction, nanoparticle synthesis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review