WAVELET DE-NOISING OF OPTICAL TERAHERTZ PULSE IMAGING DATA
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Terahertz pulse imaging (TPI) systems are used to obtain sub-millimeter spectroscopic measurements for a wide range of applications. This letter highlights the use of wavelet de-noising to markedly improve the SNR of the obtained data, increasing the SNR by up to 10 dB. A comparison of different wavelet families and properties is presented and the results demonstrated on THz image data of an oak leaf and an Australian $100 note.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Characterization of an optoelectronic terahertz beam system
van Exter, M., & Grischkowsky, D. R. (1990) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/22.60016 · Cited by 486 · cited 1×
“The coherent nature of T-ray systems allows them to achieve impressive performance despite very high relative noise magnitudes [3].”
BackgroundGas sensing using terahertz time-domain spectroscopy
Mittleman, D. M., Jacobsen, R. H., Neelamani, R., Baraniuk, R. G., & Nuss, M. C. (1998) · Applied Physics B: Lasers and Optics · doi:10.1007/s003400050520 · Cited by 379 · cited 1×
“Other authors have suggested using wavelet de-noising for THz imaging data [9, 10] however these are the first results investigating the performance of the technique and analyzing the suitability of different wavelet families.”
BackgroundInfluence of noise on the characterization of materials by terahertz time-domain spectroscopy
Duvillaret, L., Garet, F., & Coutaz, J.-L. (2000) · Journal of the Optical Society of America B · doi:10.1364/josab.17.000452 · Cited by 151 · cited 1×
“These include the emitter noise, which is a result of random intensity fluctuations in the ultrafast laser [1], Johnson and shot noise in the THz detector [2] as well as thermal background radiation in the THz regime.”
Background
Cited by
Highly accurate optical material parameter determination with THz time-domain spectroscopy
Pupeza, I., Wilk, R., & Koch, M. (2007) · Optics Express · doi:10.1364/oe.15.004335 · Cited by 351
Analysis of measurement uncertainty in THz-TDS
Withayachumnankul, W., Lin, H., Mickan, S. P., Fischer, B. M., & Abbott, D. (2007) · SPIE Proceedings · doi:10.1117/12.721876 · Cited by 29
Self-citationLee, M.-J., & Choi, W.-Y. (2011) · Journal of the Optical Society of Korea · doi:10.3807/josk.2011.15.1.001 · Cited by 16
Skorobogatiy, M., Sadasivan, J., & Guerboukha, H. (2018) · IEEE Transactions on Terahertz Science and Technology · doi:10.1109/tthz.2018.2814820 · Cited by 11
Metadata
- Authors
- FERGUSON, B., & ABBOTT, D.
- Venue
- Fluctuation and Noise Letters
- Publisher
- World Scientific Pub Co Pte Lt
- Published
- 2001-06
- Volume
- 01
- Issue
- 02
- Pages
- L65-L69
- ISSN
- 0219-4775 (ISSN-L)
- 1793-6780
- OpenAlex
- W2127629157
- Cited by
- 44
- References
- 3
- FWCI
- 5.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: WAVELET DE-NOISING OF OPTICAL TERAHERTZ PULSE IMAGING DATA. https://app.cochat.ai/papers/10.1142/s0219477501000226
- The paper
- FERGUSON, B., & ABBOTT, D. (2001). WAVELET DE-NOISING OF OPTICAL TERAHERTZ PULSE IMAGING DATA. Fluctuation and Noise Letters. https://doi.org/10.1142/s0219477501000226
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.