EXPERIMENTAL SIGNATURE OF REGISTRATION NOISE IN PULSED TERAHERTZ SYSTEMS
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
This Letter reports results from time domain measurements in a terahertz pulsed imaging system and suggests that a mechanical resetting mechanism in the pump-probe delay stage results in a small but resolvable noise signal. In the setup described here, this effect dominates all other sources of noise such as the background Johnson noise or shot noise, and can hence be isolated and analysed in detail. An analysis of the noise signal is used to estimate the physical limitations of the pump-probe system being employed. A comparison of the results with an analytic prediction allows us to formulate a useful and general signature of registration noise, that should make it easy to detect in any sufficiently narrowband signal.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In [14], the e ect of a drift of the initial position of the delay line in a series of sequentially measured terahertz pulses was considered. It was shown that it led to error proportional to the THz signal shifted by a quarter cycle.”
From Correction of Optical Delay Line Errors in Terahertz Time-Domain Spectroscopy (2019) · cites this paper as [14]
In the citing paper
“The third error, the drift of the initial position of the translation stage in a series of measurements, a ects averaging over a series of terahertz spectra [14].”
From Correction of Optical Delay Line Errors in Terahertz Time-Domain Spectroscopy (2019) · cites this paper as [14]
In the citing paper
“In THz-TDS, various noise effects compromise the signal quality [23 -25]. Noise contributions include optical and electronic effects [26, 27], laser intensity variations [28], and jitter noise [29, 30].”
From Terahertz-time domain spectrometer with 90 dB peak dynamic range (2014) · cites this paper as [30]
In the citing paper
“These sources include laser intensity fluctuation [9-11], optical and electronic noise [12,13], delay line stage jitter [14], registration noise [15], and so on.”
From Uncertainty in terahertz time-domain spectroscopy measurement (2008) · cites this paper as [12]
Citations
Cites
Mittleman, D. M., Jacobsen, R. H., & Nuss, M. C. (1996) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.571768 · Cited by 806
Recent advances in terahertz imaging
Mittleman, D. M., Gupta, M., Neelamani, R., Baraniuk, R. G., Rudd, J. V., & Koch, M. (1999) · Applied Physics B: Lasers and Optics · doi:10.1007/s003400050750 · Cited by 703
The development of terahertz sources and their applications
Davies, A. G., Linfield, E. H., & Johnston, M. B. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/21/302 · Cited by 173
A modular interferometer for dispersive reflectivity measurements on highly absorbing solids
Birch, J. R., & Murray, D. K. (1978) · Infrared Physics · doi:10.1016/0020-0891(78)90131-8 · Cited by 22
Time frequency analysis techniques in terahertz pulsed imaging
Handley, J. W. (2003) · White Rose eTheses Online (University of Leeds, The University of Sheffield, University of York) · Cited by 7
Self-citationAN EMPIRICAL ANALYSIS OF NOISE IN PULSED TERAHERTZ SYSTEMS
Handley, J. W., Cohen, N., BOYLE, R. D., & Berry, E. (2006) · Fluctuation and Noise Letters · doi:10.1142/s021947750600315x · Cited by 1
Self-citation
Cited by
Fundamentals of Measurement in Terahertz Time-Domain Spectroscopy
Withayachumnankul, W., & Naftaly, M. (2014) · Journal of Infrared, Millimeter, and Terahertz Waves · doi:10.1007/s10762-013-0042-z · Cited by 288
Terahertz-time domain spectrometer with 90 dB peak dynamic range
Vieweg, N., Rettich, F., Deninger, A., Roehle, H., Dietz, R., Göbel, T., & Schell, M. (2014) · Journal of Infrared Millimeter and Terahertz Waves · doi:10.1007/s10762-014-0085-9 · Cited by 203
Uncertainty in terahertz time-domain spectroscopy measurement
Withayachumnankul, W., Fischer, B. M., Lin, H., & Abbott, D. (2008) · Journal of the Optical Society of America B · doi:10.1364/josab.25.001059 · Cited by 181
Material thickness optimization for transmission-mode terahertz time-domain spectroscopy
Withayachumnankul, W., Fischer, B. M., & Abbott, D. (2008) · Optics Express · doi:10.1364/oe.16.007382 · Cited by 108
Metrology Issues and Solutions in THz Time-Domain Spectroscopy: Noise, Errors, Calibration
Naftaly, M. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2012.2208624 · Cited by 76
Metadata
- Authors
- COHEN, N., HANDLEY, J. W., BOYLE, R. D., BRAUNSTEIN, S. L., & BERRY, E.
- Affiliations
- University of Leeds (GB)
- University of York (GB)
- Leeds General Infirmary (GB)
- Venue
- Fluctuation and Noise Letters
- Publisher
- World Scientific Pub Co Pte Lt
- Published
- 2006-03
- Volume
- 06
- Issue
- 01
- Pages
- L77-L84
- ISSN
- 0219-4775 (ISSN-L)
- 1793-6780
- OpenAlex
- W2129093067
- Semantic Scholar
- 8593ae3bc91a025795b463880f1b1e9182ae4ce9
- Cited by
- 17
- References
- 6
- Citations by year
- 2026: 1 · 2025: 1 · 2023: 2 · 2022: 2 · 2019: 2 · 2018: 1 · 2017: 1 · 2016: 1 · 2014: 1 · 2013: 1 · 2012: 1
- FWCI
- 1.01
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Fluctuation and Noise Letters (publishedVersion)
- Funders
- Engineering and Physical Sciences Research Council
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
- Physical Sciences › Engineering › Mechanics of Materials › Thermography and Photoacoustic Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting and THz Device Technology
- Keywords
- terahertz pulsed imaging, noise signature, time-domain measurement, thermal noise, shot noise
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: EXPERIMENTAL SIGNATURE OF REGISTRATION NOISE IN PULSED TERAHERTZ SYSTEMS. https://app.cochat.ai/papers/10.1142/s0219477506003161
- The paper
- COHEN, N., HANDLEY, J. W., BOYLE, R. D., BRAUNSTEIN, S. L., & BERRY, E. (2006). EXPERIMENTAL SIGNATURE OF REGISTRATION NOISE IN PULSED TERAHERTZ SYSTEMS. Fluctuation and Noise Letters. https://doi.org/10.1142/s0219477506003161
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.