SECONDARY TRANSFORM DECOUPLING OF SHIFTED NONSTATIONARY SIGNAL MODULATION COMPONENTS: APPLICATION TO PHOTOPLETHYSMOGRAPHY
The DOI matches its Crossref record.
Abstract
We present a method for the detection of pertinent signal features masked by other features with similar spectral content but which perturb (but not necessarily periodically) other constituent parts of the signal. This modulation may be a modulation in frequency and/or amplitude of a locus of chosen selected points on a transform surface. A secondary transform is then performed on this derived signal. We apply the method, which we have termed secondary wavelet feature decoupling (SWFD), to the specific problem of decomposition and analysis of signals used in pulse oximetry where perturbations of the ridges in wavelet space associated with the pulse band may be used to detect respiration features. The method has wide application to problematic signals in many other disciplines.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wavelet transforms and the ECG: a review
Addison, P. S. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/5/r01 · Cited by 908
“Further, it has been shown recently how secondary wavelet transforms of ridges can be used to provide information on the frequency and amplitude modulation of the primary signal components (Addison and Watson 2004).”
BackgroundSelf-citationBreathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review
Charlton, P. H., Birrenkott, D. A., Bonnici, T., Pimentel, M. A. F., Johnson, A. E. W., Alastruey, J., Tarassenko, L., Watkinson, P. J., Beale, R., & Clifton, D. A. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2763681 · Cited by 379
“[13], [18], [24], [28], [29], [31]–[33], [41]–[226].”
Charlton, P. H., Bonnici, T., Tarassenko, L., Clifton, D. A., Beale, R., & Watkinson, P. J. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/4/610 · Cited by 366
“XA2 AM: The maximum amplitude of the Continuous Wavelet Transform (CWT) within plausible cardiac frequencies (30–220 beats per minute) (Addison and Watson 2004).”
BackgroundRecent development of respiratory rate measurement technologies
Liu, H., Allen, J., Zheng, D., & Chen, F. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab299e · Cited by 266
Estimation of Respiratory Rate From Photoplethysmogram Data Using Time–Frequency Spectral Estimation
Chon, K. H., Dash, S., & Ju, K. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2019766 · Cited by 212
“[5]–[7], Addison and Watson [12], [13], and Clifton et al.”
BackgroundWavelet analysis in neurodynamics
Pavlov, A. N., Hramov, A. E., Koronovskii, A. A., Sitnikova, E. Y., Makarov, V. A., & Ovchinnikov, A. A. (2012) · Uspekhi Fizicheskih Nauk · doi:10.3367/ufnr.0182.201209a.0905 · Cited by 182
Dehkordi, P., Garde, A., Molavi, B., Ansermino, J. M., & Dumont, G. A. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00948 · Cited by 66
“Later, a second SST was applied to estimate IIR from respiratory-induced variation signals (Addison and Watson, 2004).”
Method
Metadata
- Authors
- ADDISON, P. S., & WATSON, J. N.
- Venue
- International Journal of Wavelets, Multiresolution and Information Processing
- Publisher
- World Scientific Pub Co Pte Lt
- Published
- 2004-03
- Volume
- 02
- Issue
- 01
- Pages
- 43-57
- ISSN
- 0219-6913 (ISSN-L)
- 1793-690X
- OpenAlex
- W2078772874
- Cited by
- 51
- References
- 0
- FWCI
- 2.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.