CoChat

Activity-aware ECG-based patient authentication for remote health monitoring

Sriram, Janani C., Shin, Minho, Choudhury, Tanzeem, Kotz, David · 2009 · Proceedings of the 2009 international conference on Multimodal interfaces
Cited by 85

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Mobile medical sensors promise to provide an efficient, accurate, and economic way to monitor patients' health outside the hospital. Patient authentication is a necessary security requirement in remote health monitoring scenarios. The monitoring system needs to make sure that the data is coming from the right person before any medical or financial decisions are made based on the data. Credential-based authentication methods (e.g., passwords, certificates) are not well-suited for remote healthcare as patients could hand over credentials to someone else. Furthermore, one-time authentication using credentials or trait-based biometrics (e.g., face, fingerprints, iris) do not cover the entire monitoring period and may lead to unauthorized post-authentication use. Recent studies have shown that the human electrocardiogram (ECG) exhibits unique patterns that can be used to discriminate individuals. However, perturbation of the ECG signal due to physical activity is a major obstacle in applying the technology in real-world situations. In this paper, we present a novel ECG and accelerometer-based system that can authenticate individuals in an ongoing manner under various activity conditions. We describe the probabilistic authentication system we have developed and present experimental results from 17 individuals.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1145/1647314.1647378

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • A Real-Time QRS Detection Algorithm

    Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855 · cited 1×

    “Baseline correction introduces some sharp discontinuities within the window, so before non-fiducial feature extraction we employ a high pass filter with coefficients adapted from [26].”
    Method
  • A nurse short message service by cellular phone in type‐2 diabetic patients for six months

    Kim, H., & Jeong, H. (2007) · Journal of Clinical Nursing · doi:10.1111/j.1365-2702.2007.01698.x · Cited by 180 · cited 1×

    “Applications include long-term care for patients with chronic disease [22, 20], assistive technology for the elderly [21], risk management for people in rehabilitation [23], lifestyle coaching for people seeking to change unhealthy behavior [8], and fitness monitoring of athletes [18].”
    Background
  • Adaptive reduction of motion artifact in the electrocardiogram

    Tong, D. A., Bartels, K. A., & Honeyager, K. S. (2002) · Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology · doi:10.1109/iembs.2002.1106451 · Cited by 122 · cited 1×

    “Tong et al. [33] and Raya and Sison [28] each proposed a noise-cancelling technique to compensate for motion artifacts in ECG data, by using additional sensors: an accelerometer and an anisotropic magnetore-298 sistive (AMR) sensor.”
    Method

Show all 3 references

Cited by

See all 85

Metadata

Authors
Sriram, J. C., Shin, M., Choudhury, T., & Kotz, D.
Venue
Proceedings of the 2009 international conference on Multimodal interfaces
Publisher
ACM
Published
2009-11-02
Pages
297-304
OpenAlex
W1984961057
Cited by
85
References
3
FWCI
7.94
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Activity-aware ECG-based patient authentication for remote health monitoring. https://app.cochat.ai/papers/10.1145/1647314.1647378
The paper
Sriram, J. C., Shin, M., Choudhury, T., & Kotz, D. (2009). Activity-aware ECG-based patient authentication for remote health monitoring. Proceedings of the 2009 international conference on Multimodal interfaces. https://doi.org/10.1145/1647314.1647378

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.