The smart thermostat: using occupancy sensors to save energy in homes
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Heating, ventilation and cooling (HVAC) is the largest source of residential energy consumption. In this paper, we demonstrate how to use cheap and simple sensing technology to automatically sense occupancy and sleep patterns in a home, and how to use these patterns to save energy by automatically turning off the home's HVAC system. We call this approach the smart thermostat. We evaluate this approach by deploying sensors in 8 homes and comparing the expected energy usage of our algorithm against existing approaches. We demonstrate that our approach will achieve a 28% energy saving on average, at a cost of approximately $25 in sensors. In comparison, a commercially-available baseline approach that uses similar sensors saves only 6.8% energy on average, and actually increases energy consumption in 4 of the 8 households.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hardin, G. (1968) · Science · doi:10.1126/science.162.3859.1243 · Cited by 25,167
Hardin, G. (2009) · Journal of Natural Resources Policy Research · doi:10.1080/19390450903037302 · Cited by 6,367
Energy Information Administration
(2007) · Choice Reviews Online · doi:10.5860/choice.44-3624 · Cited by 2,490
Activity Recognition in the Home Using Simple and Ubiquitous Sensors
Tapia, E. M., Intille, S. S., & Larson, K. (2004) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-24646-6_10 · Cited by 1,323 · cited 1×
“Therefore, the smart thermostat does not require cameras or wearable tags that may be considered intrusive to the user [22, 23] or more sophisticated sensing systems used for fine-grained tracking and activity recognition [24, 25, 26].”
BackgroundAccurate activity recognition in a home setting
van Kasteren, T., Noulas, A., Englebienne, G., & Kröse, B. (2008) · Proceedings of the 10th international conference on Ubiquitous computing · doi:10.1145/1409635.1409637 · Cited by 874
The smart floor: a mechanism for natural user identification and tracking
Orr, R. J., & Abowd, G. D. (2000) · CHI '00 Extended Abstracts on Human Factors in Computing Systems · doi:10.1145/633292.633453 · Cited by 633
Assessing the Quality of Activities in a Smart Environment
Schmitter-Edgecombe, M., & Cook, D. J. (2009) · Methods of Information in Medicine · doi:10.3414/me0592 · Cited by 403
Patel, S., Robertson, T. M., Kientz, J. A., Reynolds, M. S., & Abowd, G. D. (2007) · Ubiquitous Computing · doi:10.5555/1771592.1771608 · Cited by 331
RFID-based techniques for human-activity detection
Smith, J. R., Fishkin, K. P., Jiang, B., Mamishev, A., Philipose, M., Rea, A. D., Roy, S., & Sundara-Rajan, K. (2005) · Communications of the ACM · doi:10.1145/1081992.1082018 · Cited by 221
HydroSense: infrastructure-mediated single-point sensing of whole-home water activity
Froehlich, J. E., Larson, E., Campbell, T., Haggerty, C., Fogarty, J., & Patel, S. N. (2009) · Proceedings of the 11th international conference on Ubiquitous computing · doi:10.1145/1620545.1620581 · Cited by 182
Cited by
Research Directions for the Internet of Things
Stankovic, J. A. (2014) · IEEE Internet of Things Journal · doi:10.1109/jiot.2014.2312291 · Cited by 1,920
Self-citationThe Internet of Things vision: Key features, applications and open issues
Borgia, E. (2014) · Computer Communications · doi:10.1016/j.comcom.2014.09.008 · Cited by 1,471
Energy intelligent buildings based on user activity: A survey
Nguyen, T. A., & Aiello, M. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2012.09.005 · Cited by 714
PreHeat: controlling home heating using occupancy prediction
Scott, J., Bernheim Brush, A. J., Krumm, J., Meyers, B., Hazas, M., Hodges, S., & Villar, N. (2011) · Proceedings of the 13th international conference on Ubiquitous computing · doi:10.1145/2030112.2030151 · Cited by 379
Using machine learning techniques for occupancy-prediction-based cooling control in office buildings
Peng, Y., Rysanek, A., Nagy, Z., & Schlüter, A. (2018) · Applied Energy · doi:10.1016/j.apenergy.2017.12.002 · Cited by 332
Wireless sensor network virtualization: A survey
Khan, I., Belqasmi, F., Glitho, R., Crespi, N., Morrow, M., & Polakos, P. (2016) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2015.2412971 · Cited by 326
The Sensable City: A Survey on the Deployment and Management for Smart City Monitoring
Du, R., Santi, P., Xiao, M., Vasilakos, A. V., & Fischione, C. (2019) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2018.2881008 · Cited by 289
A Survey on Human-in-the-Loop Applications Towards an Internet of All
Nunes, D. S., Zhang, P., & Sa Silva, J. (2015) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2015.2398816 · Cited by 284
Jung, W., & Jazizadeh, F. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.01.070 · Cited by 276
Occupancy behavior based model predictive control for building indoor climate—A critical review
Mirakhorli, A., & Dong, B. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.07.036 · Cited by 225
Occupancy-based HVAC control systems in buildings: A state-of-the-art review
Esrafilian-Najafabadi, M., & Haghighat, F. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.107810 · Cited by 218
A review of occupant-centric building control strategies to reduce building energy use
Naylor, S., Gillott, M., & Lau, T. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.07.019 · Cited by 210
“In spaces with slower response times, it has been shown that effective preconditioning of the space can yield significant energy savings [118].”
BackgroundTowards Better Availability and Accountability for IoT Updates by Means of a Blockchain
Boudguiga, A., Bouzerna, N., Granboulan, L., Olivereau, A., Quesnel, F., Roger, A., & Sirdey, R. (2017) · 2017 IEEE European Symposium on Security and Privacy Workshops (EuroS&PW) · doi:10.1109/eurospw.2017.50 · Cited by 207
A Survey of Mobile Crowdsensing Techniques: A Critical Component for The Internet of Things
Liu, J., Shen, H., Narman, H. S., Chung, W., & Lin, Z. (2018) · ACM Transactions on Cyber-Physical Systems · doi:10.1145/3185504 · Cited by 201
“Human in-the-loop systems bring opportunities to broaden a range of applications which include energy management (Lu et al. 2010), healthcare (Kay et al. 2012), and automobile systems (Burnham et al. 1974; Liu and Salvucci 2001).”
BackgroundDai, X., Liu, J., & Zhang, X. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.110159 · Cited by 201
Non-Intrusive Occupancy Monitoring using Smart Meters
Chen, D., Barker, S., Subbaswamy, A., Irwin, D., & Shenoy, P. (2013) · Proceedings of the 5th ACM Workshop on Embedded Systems For Energy-Efficient Buildings · doi:10.1145/2528282.2528294 · Cited by 180
“For instance, prior work highlights that residential users often either i) do not program or ii) mis-program programmable thermostats [24].”
BackgroundInfluentialMulti-Agent Systems Applications in Energy Optimization Problems: A State-of-the-Art Review
González-Briones, A., De La Prieta, F., Mohamad, M. S., Omatu, S., & Corchado, J. M. (2018) · Energies · doi:10.3390/en11081928 · Cited by 169
“This translates into energy savings through knowledge of floor schedules and learning the schedules for programming intelligent thermostats [88].”
BackgroundReal-time detection of anomalous power consumption
Chou, J.-S., & Telaga, A. S. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.01.088 · Cited by 165
Huchuk, B., Sanner, S., & O'Brien, W. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106177 · Cited by 108
Metadata
- Authors
- Lu, J., Sookoor, T., Srinivasan, V., Gao, G., Holben, B., Stankovic, J., Field, E., & Whitehouse, K.
- Venue
- Proceedings of the 8th ACM Conference on Embedded Networked Sensor Systems
- Publisher
- ACM
- Published
- 2010-11-03
- Pages
- 211-224
- OpenAlex
- W2023346859
- Cited by
- 502
- References
- 15
- FWCI
- 83.46
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.