PossessedHand: techniques for controlling human hands using electrical muscles stimuli
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
If a device can control human hands, the device can be useful for HCI and tangible application's output. To aid the controlling of finger movement, we present PossessedHand, a device with a forearm belt that can inform when and which fingers should be moved. PossessedHand controls the user's fingers by applying electrical stimulus to the muscles around the forearm. Each muscle is stimulated via 28 electrode pads. Muscles at different depths in the forearm can be selected for simulation by varying the stimulation level. PossessedHand can automatically calibrate the system for individuals. The automatic calibration system estimates relations between each electrode pad, stimulation level and muscle movement. Experiments show that PossessedHand can control the motion of 16 joints in the hand. Further, we also discuss an application based on this device to aid in playing a musical instrument.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mapping of electrical muscle stimulation using MRI
Adams, G. R., Harris, R. T., Woodard, D., & Dudley, G. A. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.74.2.532 · Cited by 322 · cited 1×
“These muscles are located at the same position, however these muscle are at different depths in the user’s forearm [3].”
BackgroundFunctional Electrical Stimulation and rehabilitation—an hypothesis
Rushton, D. N. (2003) · Medical Engineering & Physics · doi:10.1016/s1350-4533(02)00040-1 · Cited by 307
Functional electrical stimulation for walking in paraplegia.
Marsolais, E. B., & Kobetic, R. (1987) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198769050-00014 · Cited by 259 · cited 1×
“The electrical stimulation by PossessedHand is similar to Electrical Muscle Stimulation (EMS) [5, 6, 11] and Functional Electrical Stimulation (FES) [22, 9, 11, 17, 7, 26].”
MethodField-Fote, E. C. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.23752 · Cited by 246 · cited 1×
“The electrical stimulation by PossessedHand is similar to Electrical Muscle Stimulation (EMS) [5, 6, 11] and Functional Electrical Stimulation (FES) [22, 9, 11, 17, 7, 26].”
MethodThrasher, T. A., Zivanovic, V., McIlroy, W., & Popovic, M. R. (2008) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968308317436 · Cited by 241 · cited 1×
“The electrical stimulation by PossessedHand is similar to Electrical Muscle Stimulation (EMS) [5, 6, 11] and Functional Electrical Stimulation (FES) [22, 9, 11, 17, 7, 26].”
MethodGriffin, L., Decker, M. J., Hwang, J. Y., Wang, B., Kitchen, K., Ding, Z., & Ivy, J. L. (2009) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2008.03.002 · Cited by 237 · cited 1×
“To extend the use of PossessedHand, we have to consider reaction rates, accuracy, and muscle fatigue [4, 10, 24].”
MethodFaghri, P. D., Rodgers, M. M., Glaser, R. M., Bors, J. G., Ho, C., & Akuthota, P. (1994) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/0003-9993(94)90341-7 · Cited by 236 · cited 1×
“The electrical stimulation by PossessedHand is similar to Electrical Muscle Stimulation (EMS) [5, 6, 11] and Functional Electrical Stimulation (FES) [22, 9, 11, 17, 7, 26].”
MethodFunctional Walking in Paralyzed Patients by Means of Electrical Stimulation
MARSOLAIS, E. B., & KOBETIC, R. (1983) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198305000-00005 · Cited by 165 · cited 2×
“The pulse reported is that which gives the user no pain, because it is similar to the human impulse to move muscles [5, 6, 11].”
BackgroundMethodHummelsheim, H., Maier-Loth, M., & Eickhof, C. (1997) · Journal of Rehabilitation Medicine · doi:10.2340/165019771997310 · Cited by 116
Mobile music touch: mobile tactile stimulation for passive learning
Huang, K. I., Starner, T. E., Yi–Luen, E., Weinberg, G., Kohlsdorf, D., Ahlrichs, C., & Leibrandt, R. (2010) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/1753326.1753443 · Cited by 108 · cited 1×
“Many devices and systems that directly stimulate a user’s fingers have been researched [14, 16].”
BackgroundThieme atlas of anatomy : general anatomy and musculoskeletal system
Ross, L. M., Lamperti, E. D., Schuenke, M., et al. (2006) · Thieme eBooks · Cited by 102
Using neuromuscular electrical stimulation for pseudo-haptic feedback
Kruijff, E., Schmalstieg, D., & Beckhaus, S. (2006) · ACM Symposium on Virtual Reality Software and Technology (VRST) · doi:10.1145/1180495.1180558 · Cited by 85 · cited 1×
“Watanabe et al. and Kruijff et al. presented a technique in which a user’s wrist can be controlled with two degrees of freedom by stimulating four muscles [15, 30].”
Feeling the beat where it counts: fostering multi-limb rhythm skills with the haptic drum kit
Holland, S., Bouwer, A. J., Dalgelish, M., & Hurtig, T. M. (2010) · International Conference on Tangible, Embedded, and Embodied Interaction (TEI) · doi:10.1145/1709886.1709892 · Cited by 83
Functional electrical stimulation in rehabilitation engineering: a survey
Zhang, D., Guan, T. H., Widjaja, F., & Ang, W. T. (2007) · International Convention on Rehabilitation Engineering & Assistive Technology · doi:10.1145/1328491.1328546 · Cited by 65 · cited 1×
“FES can be used to treat people with disabilities [34].”
BackgroundHakansson, N. A., & Hull, M. L. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2020175 · Cited by 20 · cited 2×
“The pulse reported is that which gives the user no pain, because it is similar to the human impulse to move muscles [5, 6, 11].”
BackgroundMethodA method to test FES-based control strategies for neuroprostheses
Poboroniuc, M.-S., & Stefan, C. (2008) · International Conference on Information and Automation · Cited by 2
Yagi, R., SUGIMOTO, Y., Nakatsuchi, Y., Handa, Y., Shimada, Y., KOMATSU, S., Naito, A., ICHIE, M., & Hoshimiya, N. (1984) · リハビリテーション医学 : 日本リハビリテーション医学会誌 · doi:10.2490/jjrm1963.21.235 · Cited by 2 · cited 1×
“EMS is similar to FES [8, 21, 31, 30, 32].”
Cited by
Lopes, P., You, S., Cheng, L.-P., Marwecki, S., & Baudisch, P. (2017) · Proceedings of the 2017 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3025453.3025600 · Cited by 300
REVEL: tactile feedback technology for augmented reality
Bau, O., & Poupyrev, I. (2012) · ACM Transactions on Graphics · doi:10.1145/2185520.2185585 · Cited by 164
Design Guideline for Developing Safe Systems that Apply Electricity to the Human Body
Kono, M., Takahashi, T., Nakamura, H., Miyaki, T., & Rekimoto, J. (2018) · ACM Transactions on Computer-Human Interaction · doi:10.1145/3184743 · Cited by 63
Self-citationYem, V., Vu, K., Kon, Y., & Kajimoto, H. (2018) · 2018 IEEE Conference on Virtual Reality and 3D User Interfaces (VR) · doi:10.1109/vr.2018.8446403 · Cited by 47
Guideband: Intuitive 3d multilevel force guidance on a wristband in virtual reality.
Tsai, H.-R., Chang, Y.-C., Wei, T.-Y., Tsao, C.-A., Koo, X. C.-Y., Wang, H.-C., & Chen, B.-Y. (2021) · Proceedings of the 2021 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3411764.3445262 · Cited by 25
“On the other hand, PossessedHand [53] uses electrical muscle stimulation (EMS) to stimulate users’ fingers to learn instruments.”
Metadata
- Authors
- Tamaki, E., Miyaki, T., & Rekimoto, J.
- Venue
- Proceedings of the SIGCHI Conference on Human Factors in Computing Systems
- Publisher
- ACM
- Published
- 2011-05-07
- Pages
- 543-552
- OpenAlex
- W2023269348
- Cited by
- 229
- References
- 17
- FWCI
- 4.78
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.