Temperature management in data centers: why some (might) like it hot

El-Sayed, Nosayba, Stefanovici, Ioan A., Amvrosiadis, George, Hwang, Andy A., Schroeder, Bianca · 2012 · Proceedings of the 12th ACM SIGMETRICS/PERFORMANCE joint international conference on Measurement and Modeling of Computer Systems

Abstract

The energy consumed by data centers is starting to make up a significant fraction of the world's energy consumption and carbon emissions. A large fraction of the consumed energy is spent on data center cooling, which has motivated a large body of work on temperature management in data centers. Interestingly, a key aspect of temperature management has not been well understood: controlling the setpoint temperature at which to run a data center's cooling system. Most data centers set their thermostat based on (conservative) suggestions by manufacturers, as there is limited understanding of how higher temperatures will affect the system. At the same time, studies suggest that increasing the temperature setpoint by just one degree could save 2-5% of the energy consumption. This paper provides a multi-faceted study of temperature management in data centers. We use a large collection of field data from different production environments to study the impact of temperature on hardware reliability, including the reliability of the storage subsystem, the memory subsystem and server reliability as a whole. We also use an experimental testbed based on a thermal chamber and a large array of benchmarks to study two other potential issues with higher data center temperatures: the effect on server performance and power. Based on our findings, we make recommendations for temperature management in data centers, that create the potential for saving energy, while limiting negative effects on system reliability and performance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1145/2254756.2254778

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 28

  1. 10.1016/S0022-2836(05)80360-2 · doi:10.1016/s0022-2836(05)80360-2 · Paper page
  2. D. Anderson , J. Dykes , and E. Riedel . More than an interface--SCSI vs . ATA. In Proc. of FAST 2003 . D. Anderson, J. Dykes, and E. Riedel. More than an interface--SCSI vs. ATA. In Proc. of FAST 2003.
  3. 10.1145/1254882.1254917 · DOI · Paper page
  4. C. Belady , A. Rawson , J. Pfleuger , and T. Cader . The Green Grid Data Center Power Efficiency Metrics: PUE & DCiE. Technical report , Green Grid , 2008 . C. Belady, A. Rawson, J. Pfleuger, and T. Cader. The Green Grid Data Center Power Efficiency Metrics: PUE & DCiE. Technical report, Green Grid, 2008.
  5. 10.1147/rd.475.0703 · doi:10.1147/rd.475.0703
  6. J. Brandon . Going Green In The Data Center: Practical Steps For Your SME To Become More Environmentally Friendly . Processor , 29, Sept. 2007 . J. Brandon. Going Green In The Data Center: Practical Steps For Your SME To Become More Environmentally Friendly. Processor, 29, Sept. 2007.
  7. G. Cole . Estimating drive reliability in desktop computers and consumer electronics systems. TP-338.1. Seagate . 2000 . G. Cole. Estimating drive reliability in desktop computers and consumer electronics systems. TP-338.1. Seagate. 2000.
  8. 10.1093/comjnl/19.1.43 · DOI
  9. A. E. Darling , L. Carey , and W.-c. Feng . The design, implementation, and evaluation of mpiblast . In In Proc. of ClusterWorld 2003 , 2003 . A. E. Darling, L. Carey, and W.-c. Feng. The design, implementation, and evaluation of mpiblast. In In Proc. of ClusterWorld 2003, 2003.
  10. 10.5555/1060289.1060300 · doi:10.5555/1060289.1060300
  11. 10.1145/1555349.1555368 · DOI · Paper page
  12. J. M. Kaplan , W. Forrest , and N. Kindler . Revolutionizing data center energy efficiency. Technical report , McKinsey & Company , July 2008 . J. M. Kaplan, W. Forrest, and N. Kindler. Revolutionizing data center energy efficiency. Technical report, McKinsey & Company, July 2008.
  13. J. D. McCalpin . Memory bandwidth and machine balance in current high performance computers . IEEE Comp. Soc. TCCA Newsletter , pages 19 -- 25 , Dec. 1995 . J. D. McCalpin. Memory bandwidth and machine balance in current high performance computers. IEEE Comp. Soc. TCCA Newsletter, pages 19--25, Dec. 1995.
  14. L. McVoy and C. Staelin . lmbench: portable tools for performance analysis . In Proc. of USENIX ATC , 1996 . L. McVoy and C. Staelin. lmbench: portable tools for performance analysis. In Proc. of USENIX ATC, 1996.
  15. 10.1115/IPACK2003-35059 · DOI
  16. 10.1109/ITHERM.2008.4544393 · DOI · Paper page
  17. E. Pinheiro , R. Bianchini , E. V. Carrera , and T. Heath . Load balancing and unbalancing for power and performance in cluster-based systems . In Proc. of Workshop on Compilers and Operating Systems for Low Power (COLP) , 2001 . E. Pinheiro, R. Bianchini, E. V. Carrera, and T. Heath. Load balancing and unbalancing for power and performance in cluster-based systems. In Proc. of Workshop on Compilers and Operating Systems for Low Power (COLP), 2001.
  18. E. Pinheiro , W. D. Weber , and L. A. Barroso . Failure trends in a large disk drive population . In Proc. of Usenix FAST 2007 . E. Pinheiro, W. D. Weber, and L. A. Barroso. Failure trends in a large disk drive population. In Proc. of Usenix FAST 2007.
  19. 10.1109/CLUSTR.2006.311859 · doi:10.1109/clustr.2006.311859
  20. 10.5555/1153924.1154555 · doi:10.5555/1153924.1154555
  21. 10.1109/DSN.2006.5 · DOI · Paper page
  22. B. Schroeder and G. A. Gibson . Disk failures in the real world: What does an MTTF of 1,000,000 hours mean to you ? In Proc. of USENIX FAST , 2007 . B. Schroeder and G. A. Gibson. Disk failures in the real world: What does an MTTF of 1,000,000 hours mean to you? In Proc. of USENIX FAST, 2007.
  23. 10.1109/MIC.2005.10 · DOI · Paper page
  24. C. Staelin . Lmbench3 : Measuring scalability. Technical report , HP Laboratories Israel , 2002 . C. Staelin. Lmbench3: Measuring scalability. Technical report, HP Laboratories Israel, 2002.
  25. R. F. Sullivan . Alternating Cold and Hot Aisles Provides More Reliable Cooling for Server Farms . In Uptime Institute , 2000 . R. F. Sullivan. Alternating Cold and Hot Aisles Provides More Reliable Cooling for Server Farms. In Uptime Institute, 2000.
  26. Transaction Processing Performance Council . TPC Benchmark C - Rev. 5.11. Standard , Feb. 2010 . Transaction Processing Performance Council. TPC Benchmark C - Rev. 5.11. Standard, Feb. 2010.
  27. Transaction Processing Performance Council . TPC Benchmark H - Rev. 2.14.2. Standard , June 2011 . Transaction Processing Performance Council. TPC Benchmark H - Rev. 2.14.2. Standard, June 2011.
  28. 10.1145/358274.358283 · doi:10.1145/358274.358283

Cited by

See all 196

Metadata

Authors
El-Sayed, N., Stefanovici, I. A., Amvrosiadis, G., Hwang, A. A., & Schroeder, B.
Venue
Proceedings of the 12th ACM SIGMETRICS/PERFORMANCE joint international conference on Measurement and Modeling of Computer Systems
Publisher
ACM
Published
2012-06-11
Pages
163-174
OpenAlex
W2101221989
Cited by
196
References
1
FWCI
14.24
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Temperature management in data centers: why some (might) like it hot. https://app.cochat.ai/papers/10.1145/2254756.2254778
The paper
El-Sayed, N., Stefanovici, I. A., Amvrosiadis, G., Hwang, A. A., & Schroeder, B. (2012). Temperature management in data centers: why some (might) like it hot. Proceedings of the 12th ACM SIGMETRICS/PERFORMANCE joint international conference on Measurement and Modeling of Computer Systems. https://doi.org/10.1145/2254756.2254778

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.