The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Energy storage in datacenters: what, where, and how much?
Abstract
Energy storage - in the form of UPS units - in a datacenter has been primarily used to fail-over to diesel generators upon power outages. There has been recent interest in using these Energy Storage Devices (ESDs) for demand-response (DR) to either shift peak demand away from high tariff periods, or to shave demand allowing aggressive under-provisioning of the power infrastructure. All such prior work has only considered a single/specific type of ESD (typically re-chargeable lead-acid batteries), and has only employed them at a single level of the power delivery network. Continuing technological advances have provided us a plethora of competitive ESD options ranging from ultra-capacitors, to different kinds of batteries, flywheels and even compressed air-based storage. These ESDs offer very different trade-offs between their power and energy costs, densities, lifetimes, and energy efficiency, among other factors, suggesting that employing hybrid combinations of these may allow more effective DR than with a single technology. Furthermore, ESDs can be placed at different, and possibly multiple, levels of the power delivery hierarchy with different associated trade-offs. To our knowledge, no prior work has studied the extensive design space involving multiple ESD technology provisioning and placement options. This paper intends to fill this critical void, by presenting a theoretical framework for capturing important characteristics of different ESD technologies, the trade-offs of placing them at different levels of the power hierarchy, and quantifying the resulting cost-benefit trade-offs as a function of workload properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Progress in electrical energy storage system: a critical review
Chen, H., Cong, T. N., Yang, W., Tan, C., Li, Y., & Ding, Y. (2009) · Progress in Natural Science · doi:10.1016/j.pnsc.2008.07.014 · Cited by 3,746
Cited by
Electrical energy storage systems: A comparative life cycle cost analysis
Zakeri, B., & Syri, S. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.10.011 · Cited by 1,861
Review of energy storage system for wind power integration support
Zhao, H., Wu, Q., Hu, S., Xu, H., & Rasmussen, C. N. (2015) · Applied Energy · doi:10.1016/j.apenergy.2014.04.103 · Cited by 1,134
Barroso, L. A., Clidaras, J., & Hölzle, U. (2013) · Synthesis lectures on computer architecture · doi:10.2200/s00516ed2v01y201306cac024 · Cited by 489
Control Strategies for Microgrids With Distributed Energy Storage Systems: An Overview
Morstyn, T., Hredzak, B., & Agelidis, V. G. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2637958 · Cited by 454
Shi, Y., Xu, B., Wang, D., & Zhang, B. (2018) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2017.2749512 · Cited by 419
Self-citation
Metadata
- Authors
- Wang, D., Ren, C., Sivasubramaniam, A., Urgaonkar, B., & Fathy, H.
- Venue
- Proceedings of the 12th ACM SIGMETRICS/PERFORMANCE joint international conference on Measurement and Modeling of Computer Systems
- Publisher
- ACM
- Published
- 2012-06-11
- Pages
- 187-198
- OpenAlex
- W2162334945
- Cited by
- 211
- References
- 1
- FWCI
- 34.39
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Energy storage in datacenters: what, where, and how much? https://app.cochat.ai/papers/10.1145/2254756.2254780
- The paper
- Wang, D., Ren, C., Sivasubramaniam, A., Urgaonkar, B., & Fathy, H. (2012). Energy storage in datacenters: what, where, and how much? Proceedings of the 12th ACM SIGMETRICS/PERFORMANCE joint international conference on Measurement and Modeling of Computer Systems. https://doi.org/10.1145/2254756.2254780
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.