Energy storage in datacenters: what, where, and how much?
The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Energy storage - in the form of UPS units - in a datacenter has been primarily used to fail-over to diesel generators upon power outages. There has been recent interest in using these Energy Storage Devices (ESDs) for demand-response (DR) to either shift peak demand away from high tariff periods, or to shave demand allowing aggressive under-provisioning of the power infrastructure. All such prior work has only considered a single/specific type of ESD (typically re-chargeable lead-acid batteries), and has only employed them at a single level of the power delivery network. Continuing technological advances have provided us a plethora of competitive ESD options ranging from ultra-capacitors, to different kinds of batteries, flywheels and even compressed air-based storage. These ESDs offer very different trade-offs between their power and energy costs, densities, lifetimes, and energy efficiency, among other factors, suggesting that employing hybrid combinations of these may allow more effective DR than with a single technology. Furthermore, ESDs can be placed at different, and possibly multiple, levels of the power delivery hierarchy with different associated trade-offs. To our knowledge, no prior work has studied the extensive design space involving multiple ESD technology provisioning and placement options. This paper intends to fill this critical void, by presenting a theoretical framework for capturing important characteristics of different ESD technologies, the trade-offs of placing them at different levels of the power hierarchy, and quantifying the resulting cost-benefit trade-offs as a function of workload properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Progress in electrical energy storage system: a critical review
Chen, H., Cong, T. N., Yang, W., Tan, C., Li, Y., & Ding, Y. (2009) · Progress in Natural Science · doi:10.1016/j.pnsc.2008.07.014 · Cited by 3,746
Wattch: a framework for architectural-level power analysis and optimizations
Brooks, D., Tiwari, V., & Martonosi, M. (2000) · Proceedings of the 27th annual international symposium on Computer architecture - ISCA '00 · doi:10.1145/339647.339657 · Cited by 2,578
Battery energy storage technology for power systems—An overview
Divya, K. C., & Østergaard, J. (2009) · Electric Power Systems Research · doi:10.1016/j.epsr.2008.09.017 · Cited by 1,842 · cited 2×
“Table 1: ESD parameter values [9, 10, 38, 39].”
BackgroundPower provisioning for a warehouse-sized computer
Fan, X., Weber, W.-D., & Barroso, L. A. (2007) · Proceedings of the 34th annual international symposium on Computer architecture · doi:10.1145/1250662.1250665 · Cited by 1,797 · cited 16×
“B (savings, cost) HybSin (savings, cost) HybMul (savings, cost) Datacenter CAES (4.9k,0.4k) FW+LA+CAES (5.2k,0.3k) FW+CAES -LA (5.2k,0.3k) Rack LA (4.7k,0.3k) UC+LA (4.8k,0.3k) Server LA (3.9k,0.2k) UC+LA (4.7k,0.5k) Table 4: Google Workload: (Savings($/day), ESD costs($/day).”
BackgroundResultInfluentialThe Datacenter as a Computer: An Introduction to the Design of Warehouse-Scale Machines
Barroso, L. A., & Hölzle, U. (2009) · Synthesis lectures on computer architecture · doi:10.2200/s00193ed1v01y200905cac006 · Cited by 1,714 · cited 1×
“….ll this critical void, by presenting a theoretical framework for capturing important characteristics of di.erent ESD technologies, the trade-o.s of placing them at di.erent levels of the power hierarchy, and quantifying the resulting cost-bene.t trade-o.s as a function of workload properties.”
BackgroundManaging energy and server resources in hosting centers
Chase, J. S., Anderson, D. C., Thakar, P. N., Vahdat, A. M., & Doyle, R. P. (2001) · Proceedings of the eighteenth ACM symposium on Operating systems principles · doi:10.1145/502034.502045 · Cited by 1,284
Cutting the electric bill for internet-scale systems
Qureshi, A., Weber, R., Balakrishnan, H., Guttag, J., & Maggs, B. (2009) · Proceedings of the ACM SIGCOMM 2009 conference on Data communication · doi:10.1145/1592568.1592584 · Cited by 830 · cited 1×
“- dynamic workload redistribution to datacenter sites with cheaper prices or power availability [34, 46] and (ii) within a datacenter - complementing the utility draw with energy storage during periods when energy is expensive or unavailable [43], workload scheduling/postponement to match electricity price [25], etc.”
BackgroundInternet Web servers: workload characterization and performance implications
Arlitt, M. F., & Williamson, C. L. (1997) · IEEE/ACM Transactions on Networking · doi:10.1109/90.649565 · Cited by 730 · cited 1×
“, [1]) and properties such as time-of-day effects, etc.”
BackgroundEnergy-aware server provisioning and load dispatching for connection-intensive internet services
Gong, C., He, W., Liu, J., Nath, S., Rigas, L., Xiao, L., & Zhao, F. (2008) · Cited by 654
Barroso, L. A., Clidaras, J., & Hölzle, U. (2013) · Synthesis lectures on computer architecture · doi:10.2200/s00516ed2v01y201306cac024 · Cited by 489
Cited by
Electrical energy storage systems: A comparative life cycle cost analysis
Zakeri, B., & Syri, S. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.10.011 · Cited by 1,861
Review of energy storage system for wind power integration support
Zhao, H., Wu, Q., Hu, S., Xu, H., & Rasmussen, C. N. (2015) · Applied Energy · doi:10.1016/j.apenergy.2014.04.103 · Cited by 1,134
Barroso, L. A., Clidaras, J., & Hölzle, U. (2013) · Synthesis lectures on computer architecture · doi:10.2200/s00516ed2v01y201306cac024 · Cited by 489
Control Strategies for Microgrids With Distributed Energy Storage Systems: An Overview
Morstyn, T., Hredzak, B., & Agelidis, V. G. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2637958 · Cited by 454
Shi, Y., Xu, B., Wang, D., & Zhang, B. (2018) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2017.2749512 · Cited by 419
Self-citationEnergy efficiency and renewable energy integration in data centres. Strategies and modelling review
Oró, E., Depoorter, V., Garcia, A., & Salom, J. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.10.035 · Cited by 318
Parasol and GreenSwitch: managing datacenters powered by renewable energy
Goiri, Í., Katsak, W., Le, K., Nguyen, T. D., & Bianchini, R. (2013) · Proceedings of the eighteenth international conference on Architectural support for programming languages and operating systems · doi:10.1145/2451116.2451123 · Cited by 236
Carbon-Aware Energy Capacity Planning for Datacenters
Ren, C., Wang, D., Urgaonkar, B., & Sivasubramaniam, A. (2012) · 2012 IEEE 20th International Symposium on Modeling, Analysis and Simulation of Computer and Telecommunication Systems · doi:10.1109/mascots.2012.51 · Cited by 173
“We do not show them here due to limited space and we refer the readers to our prior work [39] for details.”
BackgroundSelf-citationCooperative Multi-Agent Control of Heterogeneous Storage Devices Distributed in a DC Microgrid
Morstyn, T., Hredzak, B., & Agelidis, V. G. (2016) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2015.2469725 · Cited by 166
“In [17] it was shown that for datacenters, operational and capital expenditure savings can be obtained with high power density ES technologies located near loads, and bulk ES technologies at higher levels of the power distribution hierarchy.”
Background(2018) · doi:10.1109/tcc.2016.2535201 · Cited by 39
Metadata
- Authors
- Wang, D., Ren, C., Sivasubramaniam, A., Urgaonkar, B., & Fathy, H.
- Venue
- Proceedings of the 12th ACM SIGMETRICS/PERFORMANCE joint international conference on Measurement and Modeling of Computer Systems
- Publisher
- ACM
- Published
- 2012-06-11
- Pages
- 187-198
- OpenAlex
- W2162334945
- Cited by
- 211
- References
- 33
- FWCI
- 34.39
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.