Sentinel: occupancy based HVAC actuation using existing WiFi infrastructure within commercial buildings
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Commercial buildings contribute to 19% of the primary energy consumption in the US, with HVAC systems accounting for 39.6% of this usage. To reduce HVAC energy use, prior studies have proposed using wireless occupancy sensors or even cameras for occupancy based actuation showing energy savings of up to 42%. However, most of these solutions require these sensors and the associated network to be designed, deployed, tested and maintained within existing buildings which is significantly costly.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
RADAR: an in-building RF-based user location and tracking system
Bahl, P., & Padmanabhan, V. N. (2002) · Proceedings IEEE INFOCOM 2000. Conference on Computer Communications. Nineteenth Annual Joint Conference of the IEEE Computer and Communications Societies (Cat. No.00CH37064) · doi:10.1109/infcom.2000.832252 · Cited by 8,380 · cited 2×
“speakers [37], WiFi [15, 50, 20], geo-magnetism [21], HVAC ductwork [41], or a combination of these [49].”
BackgroundEnergyPlus: creating a new-generation building energy simulation program
Crawley, D. B., Lawrie, L. K., Winkelmann, F. C., Buhl, W. F., Huang, Y. J., Pedersen, C. O., Strand, R. K., Liesen, R. J., Fisher, D. E., Witte, M. J., et al. (2001) · Energy and Buildings · doi:10.1016/s0378-7788(00)00114-6 · Cited by 2,822
The Horus WLAN location determination system
Youssef, M., & Agrawala, A. (2005) · Proceedings of the 3rd international conference on Mobile systems, applications, and services · doi:10.1145/1067170.1067193 · Cited by 1,653
An Analysis of Power Consumption in a Smartphone
Carroll, A., & Heiser, G. A. (2010) · Cited by 1,363
Zhang, L., Tiwana, B., Qian, Z., Wang, Z., Dick, R. P., Mao, Z. M., & Yang, L. (2010) · Proceedings of the eighth IEEE/ACM/IFIP international conference on Hardware/software codesign and system synthesis · doi:10.1145/1878961.1878982 · Cited by 1,122
Energy consumption in mobile phones: a measurement study and implications for network applications
Balasubramanian, N., Balasubramanian, A., & Venkataramani, A. (2009) · Proceedings of the 9th ACM SIGCOMM conference on Internet measurement · doi:10.1145/1644893.1644927 · Cited by 1,101
Indoor localization without the pain
Chintalapudi, K., Padmanabha Iyer, A., & Padmanabhan, V. N. (2010) · Proceedings of the sixteenth annual international conference on Mobile computing and networking · doi:10.1145/1859995.1860016 · Cited by 962
No need to war-drive: unsupervised indoor localization
Wang, H., Sen, S., Elgohary, A., Farid, M., Youssef, M., & Choudhury, R. R. (2012) · Proceedings of the 10th international conference on Mobile systems, applications, and services · doi:10.1145/2307636.2307655 · Cited by 828
Occupancy-driven energy management for smart building automation
Agarwal, Y., Balaji, B., Gupta, R., Lyles, J., Wei, M., & Weng, T. (2010) · Proceedings of the 2nd ACM Workshop on Embedded Sensing Systems for Energy-Efficiency in Building · doi:10.1145/1878431.1878433 · Cited by 570
Self-citationOldewurtel, F., Parisio, A., Jones, C. N., Morari, M., Gyalistras, D., Gwerder, M., Stauch, V, Lehmann, B., & Wirth, K. (2010) · Proceedings of the 2010 American Control Conference · doi:10.1109/acc.2010.5530680 · Cited by 435
Indoor location sensing using geo-magnetism
Chung, J., Donahoe, M., Schmandt, C., Kim, I.-J., Razavai, P., & Wiseman, M. (2011) · Proceedings of the 9th international conference on Mobile systems, applications, and services · doi:10.1145/1999995.2000010 · Cited by 400
Aswani, A., Master, N., Taneja, J., Culler, D., & Tomlin, C. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2011.2161242 · Cited by 289
Rahmati, A., & Zhong, L. (2007) · International Conference on Mobile Systems, Applications, and Services · doi:10.1145/1247660.1247681 · Cited by 262
sMAP: a simple measurement and actuation profile for physical information
Dawson-Haggerty, S., Jiang, X., Tolle, G., Ortiz, J., & Culler, D. (2010) · Proceedings of the 8th ACM Conference on Embedded Networked Sensor Systems · doi:10.1145/1869983.1870003 · Cited by 228
Occupancy-based zone-climate control for energy-efficient buildings: Complexity vs. performance
Goyal, S., Ingley, H. A., & Barooah, P. (2013) · Applied Energy · doi:10.1016/j.apenergy.2013.01.039 · Cited by 225
ENERNET: Studying the dynamic relationship between building occupancy and energy consumption
Martani, C., Lee, D., Robinson, P., Britter, R. E., & Ratti, C. (2012) · Energy and Buildings · doi:10.1016/j.enbuild.2011.12.037 · Cited by 213
Wireless wakeups revisited: energy management for voip over wi-fi smartphones
Agarwal, Y., Chandra, R., Wolman, A., Bahl, P., Chin, K., & Gupta, R. (2007) · Proceedings of the 5th international conference on Mobile systems, applications and services · doi:10.1145/1247660.1247682 · Cited by 201
Self-citationDuty-cycling buildings aggressively: The next frontier in HVAC control
Agarwal, Y., Balaji, B., Dutta, S., et al. (2011) · Information Processing in Sensor Networks · Cited by 201
Self-citationIndoor pseudo-ranging of mobile devices using ultrasonic chirps
Lazik, P., & Rowe, A. (2012) · Proceedings of the 10th ACM Conference on Embedded Network Sensor Systems · doi:10.1145/2426656.2426667 · Cited by 193
POEM: Power-efficient occupancy-based energy management system
Erickson, V. L., Achleitner, S., & Cerpa, A. E. (2013) · International Symposium on Information Processing in Sensor Networks · doi:10.1145/2461381.2461407 · Cited by 191
Measuring building occupancy using existing network infrastructure
Melfi, R., Rosenblum, B., Nordman, B., & Christensen, K. (2011) · 2011 International Green Computing Conference and Workshops · doi:10.1109/igcc.2011.6008560 · Cited by 191
Patel, S., Reynolds, M. S., & Abowd, G. D. (2008) · Lecture notes in computer science · doi:10.1007/978-3-540-79576-6_1 · Cited by 130
PowerLine Positioning: A Practical Sub-Room-Level Indoor Location System for Domestic Use
Patel, S., Truong, K. N., & Abowd, G. D. (2006) · Lecture notes in computer science · doi:10.1007/11853565_26 · Cited by 125
BOSS: building operating system services
Dawson-Haggerty, S., Krioukov, A., Taneja, J., Karandikar, S., Fierro, G., Kitaev, N., & Culler, D. (2013) · Cited by 121
BACnetTM: a standard communication infrastructure for intelligent buildings
Bushby, S. T. (1997) · Automation in Construction · doi:10.1016/s0926-5805(97)00029-0 · Cited by 108
Occupancy detection in commercial buildings using opportunistic context sources
Ghai, S. K., Thanayankizil, L. V., Seetharam, D. P., & Chakraborty, D. (2012) · IEEE International Conference on Pervasive Computing and Communications Workshops (PerCom Workshops) · doi:10.1109/percomw.2012.6197536 · Cited by 106
On the empirical performance of self-calibrating WiFi location systems
Turner, D., Savage, S., & Snoeren, A. C. (2011) · Conference on Local Computer Networks · doi:10.1109/lcn.2011.6115548 · Cited by 53
Enabling advanced environmental conditioning with a building application stack
Taneja, J., Krioukov, A., Dawson-Haggerty, S., & Culler, D. (2013) · International Green and Sustainable Computing Conference · doi:10.1109/igcc.2013.6604519 · Cited by 45
Dawson-Haggerty, S., Lanzisera, S., Taneja, J., et al. (2012) · International Conference on Information Processing in Sensor Networks (IPSN) · doi:10.1145/2185677.2185683 · Cited by 45
Softgreen: Towards energy management of green office buildings with soft sensors
Thanayankizil, L. V., Ghai, S. K., Chakraborty, D., & Seetharam, D. P. (2012) · International Conference on Communication Systems & Networks (COMSNETS) · doi:10.1109/comsnets.2012.6151374 · Cited by 42
Cited by
Ahmad, M. W., Mourshed, M., Mundow, D., Sisinni, M., & Rezgui, Y. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2016.03.059 · Cited by 348
O'Brien, W., Wagner, A., Schweiker, M., Mahdavi, A., Day, J., Kjærgaard, M. B., Carlucci, S., Dong, B., Tahmasebi, F., Yan, D., et al. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.106738 · Cited by 318
Building occupancy estimation and detection: A review
Chen, Z., Jiang, C., & Xie, L. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.03.084 · Cited by 280
Jung, W., & Jazizadeh, F. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.01.070 · Cited by 276
A critical review of field implementations of occupant-centric building controls
Park, J. Y., Ouf, M. M., Gunay, B., Peng, Y., O'Brien, W., Kjærgaard, M. B., & Nagy, Z. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.106351 · Cited by 274
Metadata
- Authors
- Balaji, B., Xu, J., Nwokafor, A., Gupta, R., & Agarwal, Y.
- Venue
- Proceedings of the 11th ACM Conference on Embedded Networked Sensor Systems
- Publisher
- ACM
- Published
- 2013-11-11
- Pages
- 1-14
- OpenAlex
- W2115873741
- Cited by
- 318
- References
- 30
- FWCI
- 53.27
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.