Moving towards a real-time system for automatically recognizing stereotypical motor movements in individuals on the autism spectrum using wireless accelerometry
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
This paper extends previous work automatically detecting stereotypical motor movements (SMM) in individuals on the autism spectrum. Using three-axis accelerometer data obtained through wearable wireless sensors, we compare recognition results for two different classifiers -- Support Vector Machine and Decision Tree -- in combination with different feature sets based on time-frequency characteristics of accelerometer data. We use data collected from six individuals on the autism spectrum who participated in two different studies conducted three years apart in classroom settings, and observe an average accuracy across all participants over time ranging from 81.2% (TPR: 0.91; FPR: 0.21) to 99.1% (TPR: 0.99; FPR: 0.01) for all combinations of classifiers and feature sets. We also provide analyses of kinematic parameters associated with observed movements in an attempt to explain classifier-feature specific performance. Based on our results, we conclude that real-time, person-dependent, adaptive algorithms are needed in order to accurately and consistently measure SMM automatically in individuals on the autism spectrum over time in real-word settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Activity Recognition from User-Annotated Acceleration Data
Bao, L., & Intille, S. S. (2004) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-24646-6_1 · Cited by 3,147
Self-citationVarieties of Repetitive Behavior in Autism: Comparisons to Mental Retardation
Bodfish, J. W., Symons, F. J., Parker, D. E., & Lewis, M. H. (2000) · Journal of Autism and Developmental Disorders · doi:10.1023/a:1005596502855 · Cited by 1,223 · cited 1×
“; (3) Had a clinically significant score on the Stereotyped Behavior subscale of the Repetitive Behavior Scale-Revised (RBS-R; [9]) for body rocking and/or hand flapping; (4) Easily tolerated the wireless sensors; and (5) Exhibited, on average, at least 10 hand flapping or body rocking incidents per hour.”
BackgroundRichler, J., Huerta, M., Bishop, S. L., & Lord, C. (2010) · Development and Psychopathology · doi:10.1017/s0954579409990265 · Cited by 335 · cited 1×
“They often persist into adulthood, albeit frequently in muted form [28].”
BackgroundMandy, W. P. L., & Skuse, D. H. (2008) · Journal of Child Psychology and Psychiatry · doi:10.1111/j.1469-7610.2008.01911.x · Cited by 169
Cited by
Kim, H., Lee, S., Lee, S., Hong, S., Kang, H., & Kim, N. (2019) · JMIR mHealth and uHealth · doi:10.2196/14149 · Cited by 131
“Numerous studies have used machine learning with wearable sensor data to improve symptom detection and for monitoring in diverse populations of neuropsychiatric patients living in real-time and in diverse life contexts [19-21].”
BackgroundMohammadian Rad, N., Van Laarhoven, T., Furlanello, C., & Marchiori, E. (2018) · Sensors · doi:10.3390/s18103533 · Cited by 76
“SMMs are the major group of abnormal repetitive behaviors, e.g., hand flapping and body rocking, in children with ASD.”
BackgroundMethodInfluentialPerseverations of the academy: a survey of wearable technologies applied to autism intervention
Williams, R. M., & Gilbert, J. E. (2020) · International Journal of Human-Computer Studies · doi:10.1016/j.ijhcs.2020.102485 · Cited by 74
IMU-Based Monitoring for Assistive Diagnosis and Management of IoHT: A Review
Bo, F., Yerebakan, M., Dai, Y., Wang, W., Li, J., Hu, B., & Gao, S. (2022) · Healthcare · doi:10.3390/healthcare10071210 · Cited by 35
Metadata
- Authors
- Goodwin, M. S., Haghighi, M., Tang, Q., Akcakaya, M., Erdogmus, D., & Intille, S.
- Venue
- Proceedings of the 2014 ACM International Joint Conference on Pervasive and Ubiquitous Computing
- Publisher
- ACM
- Published
- 2014-09-13
- Pages
- 861-872
- OpenAlex
- W2089272653
- Cited by
- 55
- References
- 4
- FWCI
- 6.82
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.