CoChat

C-FMCW Based Contactless Respiration Detection Using Acoustic Signal

Wang, Tianben, Zhang, Daqing, Zheng, Yuanqing, Gu, Tao, Zhou, Xingshe, Dorizzi, Bernadette · 2018 · Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
Cited by 180

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Recent advances in ubiquitous sensing technologies have exploited various approaches to monitoring vital signs. One of the vital signs is human respiration which typically requires reliable monitoring with low error rate in practice. Previous works in respiration monitoring however either incur high cost or suffer from poor error rate. In this paper, we propose a Correlation based Frequency Modulated Continuous Wave method (C-FMCW) which is able to achieve high ranging resolution. Based on C-FMCW, we present the design and implementation of an audio-based highly-accurate system for human respiration monitoring, leveraging on commodity speaker and microphone widely available in home environments. The basic idea behind the audio-based method is that when a user is close to a pair of speaker and microphone, body movement during respiration causes periodic audio signal changes, which can be extracted to obtain the respiration rate. However, several technical challenges exist when applying C-FMCW to detect respiration with commodity acoustic devices. First, the sampling frequency offset between speakers and microphones if not being corrected properly would cause high ranging errors. Second, the uncertain starting time difference between the speaker and microphone varies over time. Moreover, due to multipath effect, weak periodic components due to respiration can easily be overwhelmed by strong static components in practice. To address those challenges, we 1) propose an algorithm to compensate dynamically acoustic signal and counteract the offset between speaker and microphone; 2) co-locate speaker and microphone and use the received signal without reflection (self-interference) as a reference to eliminate the starting time difference; and 3) leverage the periodicity of respiration to extract weak periodic components with autocorrelation. Extensive experimental results show that our system detects respiration in real environments with the median error lower than 0.35 breaths/min, outperforming the state-of-the-arts.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1145/3161188

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 180

Metadata

Authors
Wang, T., Zhang, D., Zheng, Y., Gu, T., Zhou, X., & Dorizzi, B.
Venue
Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
Published
2018-01-08
Volume
1
Issue
4
Pages
1-20
ISSN
2474-9567 (ISSN-L)
OpenAlex
W2783985400
Cited by
180
References
3
FWCI
5.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: C-FMCW Based Contactless Respiration Detection Using Acoustic Signal. https://app.cochat.ai/papers/10.1145/3161188
The paper
Wang, T., Zhang, D., Zheng, Y., Gu, T., Zhou, X., & Dorizzi, B. (2018). C-FMCW Based Contactless Respiration Detection Using Acoustic Signal. Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies. https://doi.org/10.1145/3161188

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.