The DOI matches its Crossref record.
Project GROPEHaptic displays for scientific visualization
Open accessAbstract
We began in 1967 a project to develop a haptic+display for 6-D force fields of interacting protein molecules. We approached it in four stages: a 2-D system, a 3-D system tested with a simple task, a 6-D system tested with a simple task, and a full 6-D molecular docking system, our initial goal. This paper summarizes the entire project---the four systems, the evaluation experiments, the results, and our observations. The molecular docking system results are new.Our principal conclusions are:• Haptic display as an augmentation to visual display can improve perception and understanding both of force fields and of world models populated with impenetrable objects.• Whereas man-machine systems can outperform computer-only systems by orders of magnitude on some problems, haptic-augmented interactive systems seem to give about a two-fold performance improvement over purely graphical interactive systems. Better technology may give somewhat more, but a ten-fold improvement does not seem to be in the cards.• Chemists using GROPE-III can readily reproduce the true docking positions for drugs whose docking is known (but not to them) and can find very good docks for drugs whose true docks are unknown. The present tool promises to yield new chemistry research results; it is being actively used by research chemists.• The most valuable result from using GROPE-III for drug docking is probably the radically improved situation awareness that serious users report. Chemists say they have a new understanding of the details of the receptor site and its force fields, and of why a particular drug docks well or poorly.• We see various scientific/education applications for haptic displays but believe entertainment, not scientific visualization, will drive and pace the technology.• The hardware-software system technology we have used is barely adequate, and our experience sets priorities for future development.• Some unexpected perceptual phenomena were observed. All of these worked for us, not against us.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A myosignal-based powered exoskeleton system
Rosen, J., Brand, M., Fuchs, M. B., & Arcan, M. (2001) · IEEE Transactions on Systems, Man, and Cybernetics - Part A: Systems and Humans · doi:10.1109/3468.925661 · Cited by 437
Augmented Reality in built environment: Classification and implications for future research
Wang, X., Kim, M. J., Love, P. E. D., & Kang, S.-C. (2013) · Automation in Construction · doi:10.1016/j.autcon.2012.11.021 · Cited by 293
Haptics in Education: Exploring an Untapped Sensory Modality
Minogue, J., & Jones, M. G. (2006) · Review of Educational Research · doi:10.3102/00346543076003317 · Cited by 255
Haptic feedback: a brief history from telepresence to virtual reality
Stone, R. J. (2001) · Lecture Notes in Computer Science · doi:10.1007/3-540-44589-7_1 · Cited by 213
Air jet driven force feedback in virtual reality
Suzuki, Y., & Kobayashi, M. (2005) · IEEE Computer Graphics and Applications · doi:10.1109/mcg.2005.1 · Cited by 135
Metadata
- Authors
- Brooks, F. P., Ouh-Young, M., Batter, J. J., & Jerome Kilpatrick, P.
- Venue
- ACM SIGGRAPH Computer Graphics
- Published
- 1990-09
- Volume
- 24
- Issue
- 4
- Pages
- 177-185
- ISSN
- 0097-8930 (ISSN-L)
- OpenAlex
- W2187489085
- Cited by
- 315
- References
- 0
- FWCI
- 23.41
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Project GROPEHaptic displays for scientific visualization. https://app.cochat.ai/papers/10.1145/97880.97899
- The paper
- Brooks, F. P., Ouh-Young, M., Batter, J. J., & Jerome Kilpatrick, P. (1990). Project GROPEHaptic displays for scientific visualization. ACM SIGGRAPH Computer Graphics. https://doi.org/10.1145/97880.97899
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.