Scanning Ion Conductance Microscopy
The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
Scanning ion conductance microscopy (SICM) is a versatile type of scanning probe microscopy for studies in molecular biology and materials science. Recent advances in feedback and probe fabrication have greatly increased the resolution, stability, and speed of imaging. Noncontact imaging and the ability to deliver materials to localized areas have made SICM especially fruitful for studies of molecular biology, and many examples of such use have been reported. In this review, we highlight new developments in the operation of SICM and describe some of the most exciting recent studies from this growing field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ANIMAL CELL CYCLES AND THEIR CONTROL
Norbury, C., & Nurse, P. (1992) · Annual Review of Biochemistry · doi:10.1146/annurev.bi.61.070192.002301 · Cited by 1,274 · cited 1×
“as little as 20 min in bacteria (47) or as much as 24 h in more rapidly dividing mammalian cells (48).”
Ion‐Current Rectification in Nanopores and Nanotubes with Broken Symmetry
Siwy, Z. S. (2006) · Advanced Functional Materials · doi:10.1002/adfm.200500471 · Cited by 867 · cited 1×
“Surface conductance and conductance states for charged species within pipettes are reported to be important factors (17, 18).”
The Scanning Ion-Conductance Microscope
Hansma, P. K., Drake, B., Marti, O., Gould, S. A. C., & Prater, C. B. (1989) · Science · doi:10.1126/science.2464851 · Cited by 849
Gao, Y.-J., Zhang, L., Samad, O. A., Suter, M. R., Yasuhiko, K., Xu, Z.-Z., Park, J.-Y., Lind, A.-L., Ma, Q., & Ji, R.-R. (2009) · The Journal of Neuroscience · doi:10.1523/jneurosci.3623-08.2009 · Cited by 567
β 2 -Adrenergic Receptor Redistribution in Heart Failure Changes cAMP Compartmentation
Nikolaev, V. O., Moshkov, A., Lyon, A. R., Miragoli, M., Novak, P., Paur, H., Lohse, M. J., Korchev, Y. E., Harding, S. E., & Gorelik, J. (2010) · Science · doi:10.1126/science.1185988 · Cited by 556 · cited 1×
“Additionally, for cells isolated from rats with chronic heart failure, β2ARs were redistributed from the T tubule system to the domed-crest region of cardiomyocytes; this redistribution altered the signaling compartmentalization of cyclic AMP and, therefore, its physiological function (52, 71).”
Neher, E., Sakmann, B., & Steinbach, J. H. (1978) · Pfl�gers Archiv European Journal of Physiology · doi:10.1007/bf00584247 · Cited by 514 · cited 1×
“Scanning Patch-Clamp Technique Patch-clamp techniques have had a major impact on the fields of electrophysiology and medicine (90).”
Scanning Electrochemical Microscopy
Amemiya, S., Bard, A. J., Fan, F.-R. F., Mirkin, M. V., & Unwin, P. R. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112938 · Cited by 427 · cited 1×
“In contrast, SECM can provide spatial mapping of electrochemistry for a wide range of materials, including insulators (80, 81), metals (82, 83), and semiconductors (84, 85).”
Blood flow and vascular gene expression: fluid shear stress as a modulator of endothelial phenotype
Topper, J. N., & Gimbrone Jr, M. A. (1999) · Molecular Medicine Today · doi:10.1016/s1357-4310(98)01372-0 · Cited by 390 · cited 1×
“Shear stress from blood flow is a major contributor to the vascular endothelial cell phenotype (51).”
Lyon, A. R., MacLeod, K. T., Zhang, Y., Garcia, E., Kanda, G. K., Lab, M. J., Korchev, Y. E., Harding, S. E., & Gorelik, J. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0809777106 · Cited by 369 · cited 1×
“Ventricular myocytes derived from failing hearts (53), affected by prolonged mechanical unloading (54) or undergoing detubulation induced by osmotic shock or prolonged culture (55), were examined with SICM.”
Takahashi, Y., Shevchuk, A. I., Novak, P., Murakami, Y., Shiku, H., Korchev, Y. E., & Matsue, T. (2010) · Journal of the American Chemical Society · doi:10.1021/ja1029478 · Cited by 297 · cited 1×
“With this hybrid technology, topography and the corresponding electrochemical response for single live cells, enzyme spots, and Au film electrodes were successfully resolved at submicrometer resolution (86, 87).”
Cited by
Shi, W., Friedman, A. K., & Baker, L. A. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04260 · Cited by 430
Self-citationFilming Biomolecular Processes by High-Speed Atomic Force Microscopy
Ando, T., Uchihashi, T., & Scheuring, S. (2014) · Chemical Reviews · doi:10.1021/cr4003837 · Cited by 392
Ebejer, N., Güell, A. G., Lai, S. C. S., McKelvey, K., Snowden, M. E., & Unwin, P. R. (2013) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-062012-092650 · Cited by 355
High-Speed AFM and Applications to Biomolecular Systems
Ando, T., Uchihashi, T., & Kodera, N. (2013) · Annual Review of Biophysics · doi:10.1146/annurev-biophys-083012-130324 · Cited by 301
Perspective and Prospectus on Single-Entity Electrochemistry
Baker, L. A. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.8b09747 · Cited by 285
Self-citationConfined Nanopipette Sensing: From Single Molecules, Single Nanoparticles, to Single Cells
Yu, R., Ying, Y., Gao, R., & Long, Y. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201803229 · Cited by 255
Electrochemical Nanoprobes for Single-Cell Analysis
Actis, P., Tokar, S., Clausmeyer, J., Babakinejad, B., Mikhaleva, S., Cornut, R., Takahashi, Y., López Córdoba, A., Novak, P., Shevchuck, A. I., et al. (2014) · ACS Nano · doi:10.1021/nn405612q · Cited by 252
Chemical Analysis of Single Cells
Lin, Y., Trouillon, R., Safina, G., & Ewing, A. G. (2011) · Analytical Chemistry · doi:10.1021/ac2009838 · Cited by 250
Kranz, C., & Wächtler, M. (2021) · Chemical Society Reviews · doi:10.1039/d0cs00526f · Cited by 204
Design Strategies for Electrocatalysts from an Electrochemist’s Perspective
Linnemann, J., Kanokkanchana, K., & Tschulik, K. (2021) · ACS Catalysis · doi:10.1021/acscatal.0c04118 · Cited by 199
Single Cell “Glucose Nanosensor” Verifies Elevated Glucose Levels in Individual Cancer Cells
Nascimento, R. A. S., Özel, R. E., Mak, W. H., Mulato, M., Singaram, B., & Pourmand, N. (2016) · Nano Letters · doi:10.1021/acs.nanolett.5b04495 · Cited by 190
Nanoscale Electrochemical Mapping
Bentley, C. L., Edmondson, J., Meloni, G. N., Perry, D., Shkirskiy, V., & Unwin, P. R. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05235 · Cited by 190
Operando Scanning Electrochemical Probe Microscopy during Electrocatalysis
Santana Santos, C., Jaato, B. N., Sanjuán, I., Schuhmann, W., & Andronescu, C. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00766 · Cited by 188
Compartmental Genomics in Living Cells Revealed by Single-Cell Nanobiopsy
Actis, P., Maalouf, M. M., Kim, H. J., Lohith, A., Vilozny, B., Seger, R. A., & Pourmand, N. (2014) · ACS Nano · doi:10.1021/nn405097u · Cited by 183
Oja, S. M., Wood, M., & Zhang, B. (2013) · Analytical Chemistry · doi:10.1021/ac3031702 · Cited by 166
Key requirements for advancing machine learning approaches in single entity electrochemistry
(2024) · doi:10.1016/j.coelec.2024.101526 · Cited by 10
Metadata
- Authors
- Chen, C.-C., Zhou, Y., & Baker, L. A.
- Venue
- Annual Review of Analytical Chemistry
- Publisher
- Annual Reviews
- Published
- 2012-07-19
- Volume
- 5
- Issue
- 1
- Pages
- 207-228
- ISSN
- 1936-1327 (ISSN-L)
- 1936-1335
- OpenAlex
- W2106937165
- Cited by
- 210
- References
- 46
- FWCI
- 1.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.