Scanning Ion Conductance Microscopy
The DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
Scanning ion conductance microscopy (SICM) is a versatile type of scanning probe microscopy for studies in molecular biology and materials science. Recent advances in feedback and probe fabrication have greatly increased the resolution, stability, and speed of imaging. Noncontact imaging and the ability to deliver materials to localized areas have made SICM especially fruitful for studies of molecular biology, and many examples of such use have been reported. In this review, we highlight new developments in the operation of SICM and describe some of the most exciting recent studies from this growing field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ANIMAL CELL CYCLES AND THEIR CONTROL
Norbury, C., & Nurse, P. (1992) · Annual Review of Biochemistry · doi:10.1146/annurev.bi.61.070192.002301 · Cited by 1,274 · cited 1×
“as little as 20 min in bacteria (47) or as much as 24 h in more rapidly dividing mammalian cells (48).”
Ion‐Current Rectification in Nanopores and Nanotubes with Broken Symmetry
Siwy, Z. S. (2006) · Advanced Functional Materials · doi:10.1002/adfm.200500471 · Cited by 867 · cited 1×
“Surface conductance and conductance states for charged species within pipettes are reported to be important factors (17, 18).”
The Scanning Ion-Conductance Microscope
Hansma, P. K., Drake, B., Marti, O., Gould, S. A. C., & Prater, C. B. (1989) · Science · doi:10.1126/science.2464851 · Cited by 849
Gao, Y.-J., Zhang, L., Samad, O. A., Suter, M. R., Yasuhiko, K., Xu, Z.-Z., Park, J.-Y., Lind, A.-L., Ma, Q., & Ji, R.-R. (2009) · The Journal of Neuroscience · doi:10.1523/jneurosci.3623-08.2009 · Cited by 567
β 2 -Adrenergic Receptor Redistribution in Heart Failure Changes cAMP Compartmentation
Nikolaev, V. O., Moshkov, A., Lyon, A. R., Miragoli, M., Novak, P., Paur, H., Lohse, M. J., Korchev, Y. E., Harding, S. E., & Gorelik, J. (2010) · Science · doi:10.1126/science.1185988 · Cited by 556 · cited 1×
“Additionally, for cells isolated from rats with chronic heart failure, β2ARs were redistributed from the T tubule system to the domed-crest region of cardiomyocytes; this redistribution altered the signaling compartmentalization of cyclic AMP and, therefore, its physiological function (52, 71).”
Neher, E., Sakmann, B., & Steinbach, J. H. (1978) · Pfl�gers Archiv European Journal of Physiology · doi:10.1007/bf00584247 · Cited by 514 · cited 1×
“Scanning Patch-Clamp Technique Patch-clamp techniques have had a major impact on the fields of electrophysiology and medicine (90).”
Scanning Electrochemical Microscopy
Amemiya, S., Bard, A. J., Fan, F.-R. F., Mirkin, M. V., & Unwin, P. R. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112938 · Cited by 427 · cited 1×
“In contrast, SECM can provide spatial mapping of electrochemistry for a wide range of materials, including insulators (80, 81), metals (82, 83), and semiconductors (84, 85).”
Blood flow and vascular gene expression: fluid shear stress as a modulator of endothelial phenotype
Topper, J. N., & Gimbrone Jr, M. A. (1999) · Molecular Medicine Today · doi:10.1016/s1357-4310(98)01372-0 · Cited by 390 · cited 1×
“Shear stress from blood flow is a major contributor to the vascular endothelial cell phenotype (51).”
Lyon, A. R., MacLeod, K. T., Zhang, Y., Garcia, E., Kanda, G. K., Lab, M. J., Korchev, Y. E., Harding, S. E., & Gorelik, J. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0809777106 · Cited by 369 · cited 1×
“Ventricular myocytes derived from failing hearts (53), affected by prolonged mechanical unloading (54) or undergoing detubulation induced by osmotic shock or prolonged culture (55), were examined with SICM.”
Takahashi, Y., Shevchuk, A. I., Novak, P., Murakami, Y., Shiku, H., Korchev, Y. E., & Matsue, T. (2010) · Journal of the American Chemical Society · doi:10.1021/ja1029478 · Cited by 297 · cited 1×
“With this hybrid technology, topography and the corresponding electrochemical response for single live cells, enzyme spots, and Au film electrodes were successfully resolved at submicrometer resolution (86, 87).”
Imaging Proteins in Membranes of Living Cells by High‐Resolution Scanning Ion Conductance Microscopy
Shevchuk, A. I., Frolenkov, G. I., Sánchez, D., James, P. S., Freedman, N., Lab, M. J., Jones, R., Klenerman, D., & Korchev, Y. E. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200503915 · Cited by 222 · cited 2×
“SICM, with its high spatial resolution that can visualize protein complexes with a diameter of approximately 14 nm on the surfaces of living spermatozoa (28), has proven to provide adequate temporal resolution for subcellular dynamic studies (49, 50).”
Dynamic assembly of surface structures in living cells
Gorelik, J., Shevchuk, A. I., Frolenkov, G. I., Diakonov, I. A., Lab, M. J., Kros, C. J., Richardson, G. P., Vodyanoy, I., Edwards, C. R. W., Klenerman, D., et al. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1030502100 · Cited by 176 · cited 4×
“Short, nonspecialized microvilli on the surfaces of most cells, such as epithelial cells and fibroblasts, undergo a three-stage life cycle of approximately 12 min (49).”
InfluentialComstock, D. J., Elam, J. W., Pellin, M. J., & Hersam, M. C. (2010) · Analytical Chemistry · doi:10.1021/ac902224q · Cited by 169 · cited 1×
“With this hybrid technology, topography and the corresponding electrochemical response for single live cells, enzyme spots, and Au film electrodes were successfully resolved at submicrometer resolution (86, 87).”
Visualizing Zeptomole (Electro)Catalysis at Single Nanoparticles within an Ensemble
Lai, S. C. S., Dudin, P. V., Macpherson, J. V., & Unwin, P. R. (2011) · Journal of the American Chemical Society · doi:10.1021/ja203955b · Cited by 168 · cited 2×
“measurements (Figure 6), becomes a possible platform to investigate gas exchange at the meniscus for studies involved in gas-liquid-solid (electrode) interfaces is promising (89).”
Comparison of Scanning Ion Conductance Microscopy with Atomic Force Microscopy for Cell Imaging
Rheinlaender, J., Geisse, N. A., Proksch, R. B., & Schäffer, T. E. (2010) · Langmuir · doi:10.1021/la103275y · Cited by 154 · cited 1×
“Images of fibroblast extensions obtained with AFM present obvious morphological distortions that result from the inherent imaging force, whereas no evident topographic deformation has been observed in SICM images (34).”
Ying, L., White, S. S., Bruckbauer, A., et al. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74177-6 · Cited by 146 · cited 1×
“Due to the tapered geometry of a nanopipette, a potential difference (hundreds of millivolts) applied between the electrode in the nanopipette and in the bath can result in a high electric field (kilovolts per centimeter) localized at the tip (20).”
Gorelik, J., Gu, Y., Spohr, H. A., Shevchuk, A., Lab, M. J., Harding, S. E., Edwards, C. R. W., Whitaker, M., Moss, G. W. J., Benton, D. C. H., et al. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75330-7 · Cited by 129 · cited 1×
“This SICM-based patch-clamp method, termed the scanning patch-clamp or “smart” patch-clamp technique (96, 97), can perform electrophysiological recordings by positioning the nanopipette at specific locations predefined from high-resolution topographic SICM images.”
Intrarenal Purinergic Signaling in the Control of Renal Tubular Transport
Prætorius, H. A., & Leipziger, J. (2010) · Annual Review of Physiology · doi:10.1146/annurev-physiol-021909-135825 · Cited by 129 · cited 5×
“Apical P2 receptors inhibit Na+ transport in the presence of extracellular ATP (67, 68).”
InfluentialBruckbauer, A., Zhou, D., Ying, L., Korchev, Y. E., Abell, C., & Klenerman, D. (2003) · Journal of the American Chemical Society · doi:10.1021/ja035755v · Cited by 120 · cited 1×
“Patterned surfaces have also demonstrated that after voltage deposition from the pipette, biological molecules retain activity; specifically, antibodies are still capable of specific recognition, and DNA can hybridize with complementary strands (26).”
Gorelik, J., Shevchuk, A., Ramalho, M., Elliott, M., Lei, C., Higgins, C. F., Lab, M. J., Klenerman, D., Krauzewicz, N., & Korchev, Y. E. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.252458399 · Cited by 118 · cited 5×
“SSCM has been utilized to study the entry process of virus-like particles into a cell (76, 78) and to identify the endocytic pathways of Cos-7 cells mediated by different proteins such as clathrin, caveolins, and flotillin (77).”
InfluentialTwo‐Component Graded Deposition of Biomolecules with a Double‐Barreled Nanopipette
Rodolfa, K. T., Bruckbauer, A., Zhou, D., Korchev, Y. E., & Klenerman, D. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200502338 · Cited by 117 · cited 2×
“In addition to single-barrel nanopipettes, θ nanopipettes have also been utilized extensively in SICM applications (15, 16).”
Bruckbauer, A., James, P. S., Zhou, D., Yoon, J. W., Excell, D., Korchev, Y. E., Jones, R., & Klenerman, D. (2007) · Biophysical Journal · doi:10.1529/biophysj.107.104737 · Cited by 109 · cited 1×
“Delivery of fluorescent probe molecules from a nanopipette to different positions at the membranes of sperm cells demonstrated the existence of diffusion barriers and different subregions of the cell membrane (25).”
Ying, L., Bruckbauer, A., Zhou, D., et al. (2005) · Physical Chemistry Chemical Physics · doi:10.1039/b506743j · Cited by 104 · cited 1×
“Resolution and Theoretical Models Resolution in SICM is determined by the pipette tip geometry and tip-sample distance, and the typical resolution for SICM is ∼10 nm vertically and ∼50 nm laterally (27).”
Ibrahim, M. E., Al‐Masri, A. A., Navaratnarajah, M., Siedlecka, U., Soppa, G. K. R., Moshkov, A. V., Al‐Saud, S. A., Gorelik, J., Yacoub, M. H., & Terracciano, C. M. (2010) · The FASEB Journal · doi:10.1096/fj.10-156638 · Cited by 94 · cited 1×
“Ventricular myocytes derived from failing hearts (53), affected by prolonged mechanical unloading (54) or undergoing detubulation induced by osmotic shock or prolonged culture (55), were examined with SICM.”
Programmable Delivery of DNA through a Nanopipet
Ying, L., Bruckbauer, A., Rothery, A. M., Korchev, Y. E., & Klenerman, D. (2002) · Analytical Chemistry · doi:10.1021/ac015674m · Cited by 94 · cited 1×
“Dielectrophoresis or electrophoresis can be utilized to concentrate molecules and to control deposition through the potential waveform that is applied (23).”
Pulse-mode scanning ion conductance microscopy—a method to investigate cultured hippocampal cells
Mann, S. A., Hoffmann, G. G., Hengstenberg, A., Schuhmann, W. W., & Dietzel, I. D. (2002) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00023-7 · Cited by 92
Monitoring cell movements and volume changes with pulse‐mode scanning ion conductance microscopy
Happel, P., Hoffmann, G. G., Mann, S. A., & Dietzel, I. D. (2003) · Journal of Microscopy · doi:10.1046/j.1365-2818.2003.01248.x · Cited by 91 · cited 4×
“Backstep, Hopping, and Standing Approach Modes The backstep (2, 13), hopping (3), and standing approach (4) modes of imaging were developed for samples with highly complex surface features.”
InfluentialRole of Shear Stress in Endothelial Cell Morphology and Expression of Cyclooxygenase Isoforms
Potter, C. M. F., Lundberg, M. H., Mackenzie, L. S., Warboys, C. M., Warner, T. D., Berson, R. E., Moshkov, A. V., Gorelik, J., Weinberg, P. D., & Mitchell, J. A. (2010) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/atvbaha.110.214031 · Cited by 87
The human embryonic stem cell-derived cardiomyocyte as a pharmacological model
Harding, S. E., Ali, N. N., Brito-Martins, M., & Gorelik, J. (2007) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2006.08.008 · Cited by 84
GREEN, D. J., & Gillette, R. (1983) · Nature · doi:10.1038/306784a0 · Cited by 81
P2X and P2Y purinoceptor expression in pancreas from streptozotocin-diabetic rats
Coutinho‐Silva, R., Parsons, M. E., Robson, T., Lincoln, J., & Burnstock, G. (2003) · Molecular and Cellular Endocrinology · doi:10.1016/s0303-7207(03)00003-0 · Cited by 79
Zoski, C. G., Simjee, N., Guenat, O. T., & Koudelka‐Hep, M. (2003) · Analytical Chemistry · doi:10.1021/ac034890n · Cited by 71 · cited 1×
“, toxicity) or if the electrical properties of the tip are fouled during operation in biological media (39, 40).”
Miragoli, M., Moshkov, A. V., Novák, P., Shevchuk, A., Nikolaev, V. O., El-Hamamsy, I., Potter, C. M. F., Wright, P., Kadir, S. H. S. A., Lyon, A. R., et al. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0597 · Cited by 70 · cited 3×
“distribution of L-type Ca2+ channels was concentrated in the membrane of the T tubule system (52).”
Kueng, A., Kranz, C., & Mizaikoff, B. (2004) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.10.020 · Cited by 69 · cited 1×
“In contrast, SECM can provide spatial mapping of electrochemistry for a wide range of materials, including insulators (80, 81), metals (82, 83), and semiconductors (84, 85).”
Aldosterone acts via an ATP autocrine/paracrine system: The Edelman ATP hypothesis revisited
Gorelik, J., Zhang, Y., Sánchez, D., Shevchuk, A., Frolenkov, G. I., Lab, M. J., Klenerman, D., Edwards, C. R. W., & Korchev, Y. E. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0507008102 · Cited by 67 · cited 1×
“Cell morphological responses recorded with SICM, coupled with transepithelial electrical resistance measurements, showed that ionotropic P2X4-like receptors were located at the basolateral membrane of A6 cells and facilitated Na+ transport across the epithelia (69, 70).”
ATP and adenosine in the local regulation of water transport and homeostasis by the kidney
Rieg, T., & Vallon, V. (2008) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.90784.2008 · Cited by 61 · cited 5×
“Apical P2 receptors inhibit Na+ transport in the presence of extracellular ATP (67, 68).”
InfluentialKnock-Out Mice Reveal Tissue-Specific Roles of P2Y Receptor Subtypes in Different Epithelia
Dubyak, G. (2003) · Molecular Pharmacology · doi:10.1124/mol.63.4.773 · Cited by 60
Spatial Distribution of Maxi-Anion Channel on Cardiomyocytes Detected by Smart-Patch Technique
Dutta, A. K., Korchev, Y. E., Shevchuk, A., Hayashi, S., Okada, Y., & Sabirov, R. Z. (2007) · Biophysical Journal · doi:10.1529/biophysj.107.117820 · Cited by 58 · cited 1×
“This SICM-based patch-clamp method, termed the scanning patch-clamp or “smart” patch-clamp technique (96, 97), can perform electrophysiological recordings by positioning the nanopipette at specific locations predefined from high-resolution topographic SICM images.”
Mann, S. A., Versmold, B., Marx, R., Stahlhofen, S., Dietzel, I. D., Heumann, R., & Berger, R. E. (2008) · Journal of Neuroinflammation · doi:10.1186/1742-2094-5-39 · Cited by 41 · cited 1×
“In addition to osmotic stimulation, changes in cell shape and membrane topography that arise from other molecular or pharmaceutical stimulation were investigated with SICM in diverse cell types (43, 57).”
Overview of controls in the Escherichia coli cell cycle
Vinella, D., & D’Ari, R. (1995) · BioEssays · doi:10.1002/bies.950170609 · Cited by 36 · cited 1×
“as little as 20 min in bacteria (47) or as much as 24 h in more rapidly dividing mammalian cells (48).”
Zhang, Y., Gorelik, J., Sánchez, D., Shevchuk, A., Lab, M. J., Vodyanoy, I., Klenerman, D., Edwards, C. R. W., & Korchev, Y. E. (2005) · Kidney International · doi:10.1111/j.1523-1755.2005.00499.x · Cited by 34 · cited 4×
“In addition, the processes of cell division and dead cell removal in a confluent A6 epithelial cell monolayer have been demonstrated to take approximately 4 h (12).”
InfluentialShin, W., & Gillis, K. D. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.088559 · Cited by 28 · cited 1×
“Furthermore, punctate depressions on the membrane surface of bovine chromaffin cells, generated by high K+ stimulation, were observed with SICM and correlated to the exocytosisinduced membrane depolarization of chromaffin cells in a high-K+ solution in the presence of extracellular Ca2+ ions (59).”
Proton transport in radiation-grafted membranes for fuel cells as detected by SECM
Kallio, T. M., Slevin, C. J., Sundholm, G., Holmlund, P., & Kontturi, K. (2003) · Electrochemistry Communications · doi:10.1016/s1388-2481(03)00117-6 · Cited by 23 · cited 1×
“In contrast, SECM can provide spatial mapping of electrochemistry for a wide range of materials, including insulators (80, 81), metals (82, 83), and semiconductors (84, 85).”
Black, M., Cooper, J. S., & McGinn, P. J. (2004) · Chemical Engineering Science · doi:10.1016/j.ces.2004.08.047 · Cited by 17 · cited 1×
“, toxicity) or if the electrical properties of the tip are fouled during operation in biological media (39, 40).”
Mann, S. A., MEYER, J. W., & Dietzel, I. D. (2006) · Journal of Microscopy · doi:10.1111/j.1365-2818.2006.01693.x · Cited by 10 · cited 1×
“To facilitate selection of the sample areas to be imaged, SICMs are usually mounted on an inverted optical microscope equipped with micromanipulators to assist positioning of the scanning frames (74).”
Ubelmann, F., Robine, S., & Louvard, D. (2011) · Wiley eBooks · doi:10.1002/9781118015759.ch13 · Cited by 8
Cited by
Shi, W., Friedman, A. K., & Baker, L. A. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04260 · Cited by 430
Self-citationFilming Biomolecular Processes by High-Speed Atomic Force Microscopy
Ando, T., Uchihashi, T., & Scheuring, S. (2014) · Chemical Reviews · doi:10.1021/cr4003837 · Cited by 392
Ebejer, N., Güell, A. G., Lai, S. C. S., McKelvey, K., Snowden, M. E., & Unwin, P. R. (2013) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-062012-092650 · Cited by 355
High-Speed AFM and Applications to Biomolecular Systems
Ando, T., Uchihashi, T., & Kodera, N. (2013) · Annual Review of Biophysics · doi:10.1146/annurev-biophys-083012-130324 · Cited by 301
Perspective and Prospectus on Single-Entity Electrochemistry
Baker, L. A. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.8b09747 · Cited by 285
Self-citation
Metadata
- Authors
- Chen, C.-C., Zhou, Y., & Baker, L. A.
- Venue
- Annual Review of Analytical Chemistry
- Publisher
- Annual Reviews
- Published
- 2012-07-19
- Volume
- 5
- Issue
- 1
- Pages
- 207-228
- ISSN
- 1936-1327 (ISSN-L)
- 1936-1335
- OpenAlex
- W2106937165
- Cited by
- 210
- References
- 46
- FWCI
- 1.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.