Implanted Neural Interfaces: Biochallenges and Engineered Solutions
The DOI matches its Crossref record; 147 of the 148 references it cites were found in a registry or an index.
Abstract
Neural interfaces are connections that enable two-way exchange of information with the nervous system. These connections can occur at multiple levels, including with peripheral nerves, with the spinal cord, or with the brain; in many instances, fundamental biophysical and biological challenges are shared across these levels. We review these challenges, including selectivity, stability, resolution versus invasiveness, implant-induced injury, and the host-interface response. Subsequently, we review the engineered solutions to these challenges, including electrode designs and geometry, stimulation waveforms, materials, and surface modifications. Finally, we consider emerging opportunities to improve neural interfaces, including cellular-level silicon to neuron connections, optical stimulation, and approaches to control inflammation. Overcoming the biophysical and biological challenges will enable effective high-density neural interfaces for stimulation and recording.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Communication within the nervous system is primarily through the rate and pattern of action potentials, and it is the number or spacing of these action potentials per unit time that code information. Thus, information can be introduced into the nervous system by inducing action potentials, or these action potentials can be read to obtain information from the nervous system [14].”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [14]
In the citing paper
“Peripheral nerve implants can also result in peripheral nerve injury. This can lead to Wallerian degeneration, neuropathic pain, and fibrosis, resulting in signal loss [14].”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [14]
In the citing paper
“The reported number of sensory perceptions and the locations evoked by intra-neural interfaces are very similar to those of the long-term extra-neural approaches, which led Grill et al. (2009) to conclude that the two approaches are equivalent.”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Grill et al. (2009)
In the citing paper
“A ramp pulse can be used to activate distal axons before closer ones (Grill and Mortimer, 1997; Grill et al., 2009)”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Grill et al., 2009
In the citing paper
“Hence, new therapeutic strategies for treating various refractory diseases through electrode-nerve interfaces have been developed, such as motor nerve stimulation and recording for controlling prosthetics and vagus nerve stimulation (VNS) for treating partial epilepsy, depression, heart failure (HF), and hypertension (1, 2).”
From Climbing-inspired twining electrodes using shape memory for peripheral nerve stimulation and recording (2019) · cites this paper as [2]
Citations
Cites
(1982) · Trends in Neurosciences · doi:10.1016/0166-2236(82)90076-5 · Cited by 9,089
Microglia-mediated neurotoxicity: uncovering the molecular mechanisms
Block, M. L., Zecca, L., & Hong, J.-S. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2038 · Cited by 4,110
Deep Brain Stimulation for Treatment-Resistant Depression
Mayberg, H. S., Lozano, A. M., Voon, V., McNeely, H. E., Seminowicz, D., Hamani, C., Schwalb, J. M., & Kennedy, S. H. (2005) · Neuron · doi:10.1016/j.neuron.2005.02.014 · Cited by 4,059
Henry, M. A. (1995) · The Journal of the American Dental Association · doi:10.14219/jada.archive.1995.0108 · Cited by 3,416
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Regeneration beyond the glial scar
Silver, J., & Miller, J. H. (2004) · Nature Reviews Neuroscience · doi:10.1038/nrn1326 · Cited by 3,078
Taussig, M. (2012) · Routledge eBooks · doi:10.4324/9780203397244 · Cited by 2,532
Krack, P., Batir, A., Van Blercom, N., Chabardes, S., Fraix, V., Ardouin, C., Koudsie, A., Limousin, P. D., Benazzouz, A., LeBas, J. F., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035275 · Cited by 2,249
Society for Neuroscience 2007 abstracts
Wishart, T. M., Paterson, J. M., Short, D. M., Meredith, S., Robertson, K., Sutherland, C. D., Cousin, M. A., Dutia, M. B., & Gillingwater, T. H. (2007) · Cited by 2,094
Which elements are excited in electrical stimulation of mammalian central nervous system: A review
Ranck, J. B. (1975) · Brain Research · doi:10.1016/0006-8993(75)90364-9 · Cited by 2,024
Research works printed but not linked: 7
- Vallbo AB, 1984, Hum. Neurobiol., 3, 3
- Rydevik B, 1990, Neural Prostheses Fundamental Studies, 85
- Hoffer JA, 1996, J. Rehabil. Res. Dev., 33, 145
- Bellamkonda RV, 2006, Biomaterials, 27, 3515
- Frosch MP, 2007, Basic Pathology
- 85. Deleted in press
- Shain W, 2003, IEEE Trans. Biomed. Eng., 11, 186
Cited by
Items 401–495 of 495
Control of neural interfacing in peripheral nerves through regenerative molecular guidance
Lotfi, P., & Romero‐Ortega, M. I. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091147 · Cited by 2
Tan, X., Xia, N., & Richter, C. (2016) · Springer handbook of auditory research · doi:10.1007/978-3-319-40848-4_9 · Cited by 2
Bi-directional Optrode for quantitative prediction of neural interface failure
McLaughlin, B. L., Kampasi, K., Perlin, G. E., LeBlanc, J., Achyuta, A. K. H., Kumar, P., Cook, G., Segura, C., Mittal, V., & Kipke, D. R. (2013) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2013.6696084 · Cited by 3
Ellis, T., Yıldız, H. Y., López‐Olmeda, J. F., Spedicato, M. T., Tort, L., Øverli, Ø., & Martins, C. I. M. (2011) · Springer eBooks · doi:10.1007/978-94-007-5383-9_11 · Cited by 6
Wang, H., Yang, G., Zhang, J., Li, S., & Bilal, M. (2022) · Journal of nanostructure in chemistry · doi:10.1007/s40097-022-00489-y · Cited by 3
“As a nondegradable foreign implant, the long-term biological response is closely to the functions of the electrode [45].”
BackgroundMihaylova, Y., Pozdeeva, A., Leukhin, A., Toschev, A. S., Talanov, M. O., Vallverdú, J., & Suleimanova, A. (2022) · Journal of Artificial Intelligence and Consciousness · doi:10.1142/s270507852230002x · Cited by 2
Biological and bionic hands: Natural neural coding and artificial perception
Bensmaïa, S. J. (2015) · IEEE World Haptics Conference (WHC) · doi:10.1109/whc.2015.7177674 · Cited by 2
Advancing Spine Connectomics and Neural Integration through Machine Learning and NeuroengineeringPreprint
Kumar, R. K., Sporn, K., Gowda, C., Khanna, A., Prabhakar, P., Paladugu, P., Jagadeesan, R., Clarkson, L., Chandrahasegowda, S., Kumar, T., et al. (2025) · Preprints.org · doi:10.20944/preprints202506.0518.v1 · Cited by 3
Ruggieri, P., & Angelini, A. (2022) · Clinical Orthopaedics and Related Research · doi:10.1097/corr.0000000000002213 · Cited by 1
Graphene from lab to fab: challenges and opportunities
Mamun, M. A., Hashem, A., Wahab, Y. A., Marlinda, A. R., Hossain, M. A. M., & Johan, M. R. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-26627-0.00013-0 · Cited by 1
Sasaki, H., Shimizu, S., Nerchan, R. A., Yamashita, K., Takahashi, N., Chinone, R., Kurashige, Y., Numano, R., Koida, K., Ohsawa, M., et al. (2025) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2025.100915 · Cited by 2
The Design Strategies and Applications of Engineered Nanoparticles for Traumatic Brain Injury
Xiang, C., Zhu, Y., Gao, X., Guo, F., He, X., Luo, W., Liu, W., & Gu, R. (2026) · International Journal of Nanomedicine · doi:10.2147/ijn.s591179 · Cited by 1
“260,261 Such discrepancies between early-phase promise and late-phase failure have not only eroded investigator confidence but may also have rendered regulatory agencies and funding bodies more risk-averse toward clinical trials of novel TBI therapeutics, including nanoparticle-based delivery…”
A roadmap to navigate the future of neural engineering
Grill, W. M., Chestek, C. A., Wang, Y., Aberra, A. S., Destexhe, A., Chan, R. H. M., Lu, B., Hanein, Y., Robinson, J. T., Whitmire, C., et al. (2026) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae78c2 · Cited by 3
“Despite remarkable progress, the field continues to face challenges [105, 115].”
Self-citationLung, D., Jia, Y., Blumer, R., Reissig, L. F., Zopf, L. M., Heimel, P., Kraus, C., Moro, A., Fachino, M., & Haberbusch, M. (2026) · Journal of Neural Engineering · doi:10.64898/2026.07.10.737529 · Cited by 3
Review of Thermal Management of an LED for Brain Implants
Henry, R., & Guruviah, V. (2017) · Lecture notes in electrical engineering · doi:10.1007/978-981-10-7293-2_14 · Cited by 1
Cholinergic Behaviors, Emotions, and the “Self”
Karczmar, A. G. (2013) · Journal of Molecular Neuroscience · doi:10.1007/s12031-013-0143-0 · Cited by 1
Nanotechnology for Neural Tissue Engineering
Saxena, T. K., Pai, S. B., Mukhatyar, V. J., & Bellamkonda, R. V. (2014) · CRC Press eBooks · doi:10.1201/b17444-18 · Cited by 3
Self-citationElectrodes for Nerve Recording and Stimulation
Liu, J., Tian, H., Kang, X., & Wang, M. (2017) · Toxinology · doi:10.1007/978-981-10-2798-7_43-1 · Cited by 1
Thermal Analysis of Light Source for Optogenetics Experiments
Henry, R., & Guruviah, V. (2018) · IETE Journal of Research · doi:10.1080/03772063.2018.1483745 · Cited by 1
“In-vivo biosensors have been developed as a Lab-on-Chip system for analysis of biological parameters like temperature, glucose, and nutrients [1,2].”
BackgroundMethodIntracortical microstimulation for tactile feedback in awake behaving rats
Devecıoğlu, İ., Öztürk, S., & Güçlü, B. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822828-9.00013-7 · Cited by 1
CMOS Neural Probe With Multi-Turn Micro-coil Magnetic Stimulation
Szoka, E. C., Werth, J. C., Cleland, T. A., Fried, S. I., & Molnar, A. C. (2021) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas49922.2021.9644971 · Cited by 2
Dominguez, A. L., González‐Mayorga, A., López‐Dolado, E., & Serrano, M. C. (2021) · Springer eBooks · doi:10.1007/978-3-030-81400-7_1 · Cited by 2
Frewin, C. L., Beygi, M., Bernardin, E. K., Feng, C. Y., Via, F. L., Dominguez-Viqueria, W., & Saddow, S. E. (2022) · Materials science forum · doi:10.4028/p-a08hju · Cited by 1
“Most of the current implementations of electrically active biomedical devices use silicon materials technology, which is unfortunately a material only stable in-vivo for acute periods of time, usually measured in months reliably [3, 4, 5, 6].”
BackgroundThe 2020 Roadmap for Bioelectronic Medicine
Lowe, A. L., & Thakor, N. V. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_121 · Cited by 1
Characterization of scaffolds for neural tissue engineering
Ulağ, S., Cesur, S., Ayran, M., & Bozlar, M. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-90554-1.00011-2 · Cited by 3
Kundu, A., Patrick, E. E., Currlin, S., Madler, R., Delgado, F., Fahmy, A., Verplancke, R., Ballini, M., Braeken, D., de Beeck, M. O., et al. (2024) · Micromachines · doi:10.3390/mi15020280 · Cited by 1
“Over the years, extraneural electrodes, including cuff, epineural, and FINE [6–18], and intraneural electrodes, e.g., LIFE, tfLIFE, TIME, and USEA [ 19– 39 ], have been designed and”
BackgroundNovel In Silico Strategies to Model the In Vivo Nerve Scarring Around Implanted Parylene C Devices
Sergi, P. N., del Valle, J., Stieglitz, T., Navarro, X., & Micera, S. (2024) · Applied Sciences · doi:10.3390/app142210741 · Cited by 1
Restore axonal conductance in a locally demyelinated axon with electromagnetic stimulation
Ye, H., Chen, Y., Chen, J., & Hendee, J. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/adb213 · Cited by 1
“…to the direct contact between the stimulating electrode and the tissue (Kim et al 2004, Liu et al 2017), and the formation of glial scarring around the individual electrode (Polikov et al 2005, Grill et al 2009), which leads to unpredictable changes or loss of neural response (Polikov et al 2005).”
Neural Probe Utilizing Programmable Micro-coil Magnetic Stimulation
Szoka, E. C., Werth, J. C., Lee, S., Lee, J.-I., Cortese, A. J., Cleland, T. A., Fried, S. I., & Molnar, A. C. (2021) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner49283.2021.9441227 · Cited by 1
“Furthermore, there are difficulties in maintaining long-term response consistency due to glial scarring degrading the electric field strengths over time [4].”
BackgroundBladder Volume Decoding from Afferent Neural Activity
Méndez, A. (2013) · PolyPublie (École Polytechnique de Montréal) · Cited by 2
He, X., Luo, Z., & He, S. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.06.19.660623 · Cited by 1
Saab, C. Y. (2013) · Elsevier eBooks · doi:10.1016/b978-0-12-398389-3.00007-8
Nova tecnologia para estimulação infravermelha neural da cóclea
Filho, O. A. C., Lewis, D. R., Lima, A. C., Figueiredo, S. S. R., & Lima, T. (2014) · Distúrbios da Comunicação
Astrocyte response to nanoscale topography on anodized alumina surfaces
Ganguly, D., Johnson, C. D. L., Borca-Tasciuc, D. A., & Gilbert, R. J. (2015) · Annual Northeast Biomedical Engineering Conference · doi:10.1109/nebec.2015.7117092
Translational research: application to human neural injury
Selzer, M. E., Clarke, S., Cohen, L. G., Kwakkel, G., & Miller, R. H. (2014) · Cambridge University Press eBooks · doi:10.1017/cbo9780511995583.039
Electrodeposition of Gold and Polypyrrole Thin Films for Neural Microelectrodes
Kojabad, Z. D., SANJABI, S., & Shojaosadati, S. A. (2013) · Advanced materials research · doi:10.4028/www.scientific.net/amr.829.337
Circuit and volume conductor models of transcutaneous electrical stimulation
Medina, L. E., & Grill, W. M. (2013) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2013.6696223
“Electrical stimulation of the peripheral nervous system has been used to treat chronic pain, dysfunctions of the lower urinary tract, epilepsy, and to restore motor function [1].”
BackgroundMethodSelf-citationThe Enhancement of a Chronically Implanted Microwire Electrode Performance
Shi, L., Chen, J., & Wang, S. W. (2014) · Advanced materials research · doi:10.4028/www.scientific.net/amr.960-961.689
Balasubramanian, K., & Hatsopoulos, N. G. (2015) · Springer eBooks · doi:10.1007/978-1-4614-6675-8_705
Biohybrid neural probe: A neural probe having cultured neurons between an electrode and tissue
Okita, K., Kato‐Negishi, M., Onoe, H., Gojo, R., Teshima, T., & Takeuchi, S. (2011)
Fuller, S. (2013) · Epistemology & Philosophy of Science · doi:10.5840/eps201337327 · Cited by 1
Piezoelectricity in Nanomedicine: Future Directions and Perspectives
Ciofani, G. (2012) · Nanomedicine and nanotoxicology · doi:10.1007/978-3-642-28044-3_9
“Wires used in implantable stimulators have a number of drawbacks including a higher degree of difficulty and invasiveness during surgery, a risk of infection, a substrate for growth of scar tissue, potential for lead breakage due to flexure or impact, and irritation or damage to tissues due to inherent differences in…”
BackgroundNANOTOPOGRAPHIC DEVICE FOR NEURAL SUBTYPES SEGREGATION
Silva, A. I. C. E. (2014) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT)
Misra, A., & Moxon, K. A. (2014) · iDEA - Drexel University Institutional Repository · doi:10.17918/etd-4559
In Vivo Exploration of Robust Implantable Devices Constructed From Biocompatible 3C–SiC
Frewin, C., Thomas, S., Coletti, C., & Saddow, S. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-802993-0.00007-1 · Cited by 1
Principles of Translation of Biologic Therapies in Spinal Cord Injury
Guest, J. D. (2011) · Elsevier eBooks · doi:10.1016/b978-1-4160-5316-3.00270-7 · Cited by 1
Controlling Prostheses Using PNS Invasive Interfaces for Amputees
Carpaneto, J., Citi, L., Raspopović, S., Rigosa, J., & Micera, S. (2013) · Wiley eBooks · doi:10.1002/9781118628522.ch16
On the Intimate Relationship between Man and Machine
Deliano, M. (2013) · Epistemology & Philosophy of Science · doi:10.5840/eps201337335
“Integrated with amplifiers and stimulators, these electrode systems yield brain chips, which can be durably implanted into the brain without major damage, and which can be controlled wireless from outside the skull (Grill et al., 2009).”
BackgroundPrecise and Reliable Activation of Cortex with Micro-coils
Lee, S. W., & Fried, S. I. (2017) · Springer briefs in electrical and computer engineering · doi:10.1007/978-3-319-64373-1_3
Dexamethasone Enhanced Microdialysis for Extended Intracranial Chemical Monitoring
Varner, E. L. (2017) · D-Scholarship@Pitt (University of Pittsburgh)
Neuroprostheses for Restoring Sensation
Tyler, D. J. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-805353-9.00103-0 · Cited by 1
Printing of platinum for use in neural implants
Sullivan, R. P. (2018) · Research Online (University of Wollongong)
Improving Suturing Skills for Surgical Residents and Advancing Prosthesis Control for Amputees.
Ursu, D. C. (2016) · Deep Blue (University of Michigan)
Intermuscular Coherence in the Presence of Electrical Stimulation
Norton, J. A. (2021) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2021.647430
Kondaveeti, P., & Moxon, K. A. (2010) · iDEA - Drexel University Institutional Repository · doi:10.17918/etd-3277
Cortical Somatosensory Neuroprosthesis for Active Tactile Exploration without Visual Feedback
An, J. H. (2013) · DukeSpace (Duke University)
Alba, N. A. (2013) · D-Scholarship@Pitt (University of Pittsburgh)
The 2020 Roadmap for Bioelectronic Medicine
Lowe, A. L., & Thakor, N. V. (2021) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_121-1
Neuroflex: Intraneural and Extraneural Flexible Sensor Architectures for Neural Probing
Patil, A. C., & Thakor, N. V. (2022) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_16-2
Electrodes for Nerve Recording and Stimulation
Liu, J., Tian, H., Kang, X., & Wang, M. (2018) · Micro/Nano technologies · doi:10.1007/978-981-10-5945-2_43
Amaya, J. P. (2015) · Louisiana State University · doi:10.31390/gradschool_theses.1990
State-of-the-Art Technology on Highly Miniaturized Free-Floating Neural Implants
Khalifa, A., & Etienne‐Cummings, R. (2021) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_114-1 · Cited by 1
Balasubramanian, K., & Hatsopoulos, N. G. (2022) · Springer eBooks · doi:10.1007/978-1-0716-1006-0_705
Balasubramanian, K., & Hatsopoulos, N. G. (2014) · Springer eBooks · doi:10.1007/978-1-4614-7320-6_705-1
Advancing Peripheral Nerve Interfaces in a Large Animal Model
Andreis, F. R. (2022) · VBN Forskningsportal (Aalborg Universitet) · doi:10.54337/aau478976327
Neuroflex: Intraneural and Extraneural Flexible Sensor Architectures for Neural Probing
Patil, A. C., & Thakor, N. V. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_16
Advancements in Implantable Microelectrodes: Opportunities and Risks for Neural Interface TechnologyPreprint
Ali, S. A., & Khan, R. (2023) · Preprints.org · doi:10.20944/preprints202303.0237.v1
Suhag, D. (2024) · Biomedical materials for multi-functional applications · doi:10.1007/978-981-97-5906-4_5 · Cited by 1
Flexible intracortical probes for stable neural recording: from the perspective of structure
Wang, S., Jiang, Q., & Song, J. (2024) · Flexible and Printed Electronics · doi:10.1088/2058-8585/ad71dc
Rosario, M., Zhang, J., Kaleem, M. I., Chandra, N. S., Yan, Y., Moran, D. W., Wood, M. D., Ray, W. Z., & MacEwan, M. R. (2024) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2024.110295
Advanced Fibers for Optogenetic Modulation
Du, M., & Zhou, S. (2024) · Wiley eBooks · doi:10.1002/9783527839322.ch7
Soft Materials for Wearable Electronics
Roy, A., & Adhikari, A. (2024) · Advanced structured materials · doi:10.1007/978-981-97-9468-3_11 · Cited by 3
Engineered hydrogel coating for improved biocompatibility of chronically implanted neural electrodes
Stüve, A. I. R. (2022) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · doi:10.34626/smcs-2n14
Ogrodnik, E. (2022) · reposiTUm (TU Wien) · doi:10.34726/hss.2022.100722
Additional file 1 of Stressor controllability modulates the stress response in fish
Cerqueira, M. A. C., Millot, S., Silva, T., Félix, A. S., Castanheira, M. F., Rey, S., MacKenzie, S. A., Oliveira, G. A., Oliveira, C. C. V., & Oliveira, R. F. (2021) · Figshare · doi:10.6084/m9.figshare.15110158
D’Alessio, A. (2021) · Electronic Theses and Dissertations Repository (University of Pisa)
Understanding factors affecting perception and utilization of artificial sensory location
Cuberovic, I. (2020) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 1
Ultrasound Modulation of the Central and Peripheral Nervous System
Gulick, D. W. (2015) · Arizona State University Library Digital Repository (Arizona State University)
Characterization of Graphene Field-Effect Transistor Arrays With a Movable Local Current Source
Salpavaara, T., Yilmaz, K., Lampinen, A. M. T., Verho, J. A., Väliaho, J., Emelianov, A. V., Hännikäinen, V., Johansson, A., Pettersson, M., Narkilahti, S., et al. (2026) · IEEE Sensors Journal · doi:10.1109/jsen.2026.3674532
“A nerve-to-machine interface is a system that enables bidirectional electrical communication between neurons and an electronic device [13].”
Despouy, E. (2019) · theses.fr (ABES) · doi:10.70675/5903e0fdz9e05z4aa9z8acazb5f1f807aff8 · Cited by 1
“Les enregistrements neuronaux obtenus à partir de microélectrodes fixes sont irréguliers et peu fiables pour réaliser des enregistrements de longue durée (Engel et al., 2005; Polikov et al., 2005; Grill et al., 2009).”
BackgroundNeuromorphic algorithms and hardware for event-based processing
Lenz, G. (2021) · theses.fr (ABES) · doi:10.70675/25b97a6dzc185z429czac72z56bfdedbd8b6 · Cited by 1
Near-Infrared-II Chemo-Optogenetics for Deep-Brain StimulationPreprint
Yin, H., Li, T., Wu, F., Jiang, W., 袁钦辉, Wang, T., Zhang, Y., Li, C., Jiang, J., Chen, G., et al. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.05.13.724823
Neurorobotics for Neurorehabilitation: Clinical Applications and Future Research Direction
Brossy, T., Katic, N., & Raspopović, S. (2026) · Springer eBooks · doi:10.1007/978-981-96-7448-0_35-1
Kuzinkovas, D., Cuttaz, E. A., Lee, A., Goding, J. A., & Green, R. A. (2025) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner61569.2025.11588914
“While their stimulation selectivity is irrefutable, damage to the nerve prevents TIME arrays from being widely used clinically [6][7][8].”
Gong, Z., Ge, N., Cao, S., 田开熙, & Yu, S. P. (2026) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2026.3720921
“However, cross-session variability arises from the physical instability of recording interfaces [10], [11].”
Smart protein therapeutics as a biological closed loop control system for neural regulation
Alfaifi, K. A. (2026) · Discover Neuroscience · doi:10.1186/s13064-026-00309-x
Zhang, J., Lam, V. H., Nuzov, N. B., Brunsman, B. A. S., Pascol, T., Onabiyi, A., Prince, R., Kalpatthi, H., Gustafson, K. J., Triolo, R. J., et al. (2026) · Scientific Reports · doi:10.1038/s41598-026-71801-x
A 1-MHz bio-impedance sensing IC with implicit digitization for ultra-fast bio-impedance detection
Ma, S., Liu, X., Yuan, Z., Lu, Y., Jiang, M., Wan, P., Jia, H., Ma, H., Guo, X., & Chen, Z. (2026) · Microelectronics Journal · doi:10.1016/j.mejo.2026.107546
Galletta, V., Fiocchi, S., Verardo, C., Carbone, L., del Mercato, L. L., Romeni, S., & Chiaramello, E. (2026) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2026.1951247
“…is a well-established method used to introduce information into the nervous system, with the final aim of exerting external control on the biological system or restoring impaired functions (Grill et al., 2009; Benabid, 2003; Wagner et al., 2018; Peckham and Knutson, 2005; Birmingham et al., 2014).”
Pour, R. K., Maarefvand, M., Emamdjomeh, H., & MohammadFarhadi (2026) · Hearing Research · doi:10.1016/j.heares.2026.109834
Photoactivatable organic neuroimplant for inhibition of peripheral nociceptive signals
Kanayeva, M., Yusupovskaya, E. A., Isaev, N. R., Markov, A. G., & Telyshev, D. V. (2026) · Biomedical Engineering · doi:10.1007/s10527-026-10555-2
Zeolites as key-components for electronics and biomedicine
Lülf, H. (2013) · theses.fr (ABES) · doi:10.70675/10f7df5fz3a2dz4baezbd5az3647978600c6
Metadata
- Authors
- Grill, W. M., Norman, S. E., & Bellamkonda, R. V.
- Affiliations
- Duke University (US)
- Georgia Institute of Technology (US)
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2009-08-01
- Volume
- 11
- Issue
- 1
- Pages
- 1-24
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2118756387
- Semantic Scholar
- 46b193b47ceebfd3b792cc3da8f142b50b7cffb3
- Cited by
- 488
- References
- 148
- Citations by year
- 2026: 14 · 2025: 15 · 2024: 26 · 2023: 31 · 2022: 24 · 2021: 39 · 2020: 37 · 2019: 43 · 2018: 35 · 2017: 43 · 2016: 34 · 2015: 35 · 2014: 25 · 2013: 29 · 2012: 17
- FWCI
- 1.67
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Annual Review of Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Social Sciences › Education › Undergraduate Neuroscience Education and Research
- Keywords
- neural interfaces, neural recording, neurostimulation, electrode design, electrode geometry, stimulation waveform, implant materials, surface modification, selectivity, peripheral nerves, spinal cord, optical stimulation, inflammation control
- MeSH terms
- Animals, Biophysics, Electric Stimulation, Electrodes, Implanted, Ganglia, Spinal, Humans, Inflammation, Models, Biological, Models, Neurological, Nerve Net, Neurons, Peripheral Nervous System, Optics and Photonics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.