Implanted Neural Interfaces: Biochallenges and Engineered Solutions
The DOI matches its Crossref record; 147 of the 148 references it cites were found in a registry or an index.
Abstract
Neural interfaces are connections that enable two-way exchange of information with the nervous system. These connections can occur at multiple levels, including with peripheral nerves, with the spinal cord, or with the brain; in many instances, fundamental biophysical and biological challenges are shared across these levels. We review these challenges, including selectivity, stability, resolution versus invasiveness, implant-induced injury, and the host-interface response. Subsequently, we review the engineered solutions to these challenges, including electrode designs and geometry, stimulation waveforms, materials, and surface modifications. Finally, we consider emerging opportunities to improve neural interfaces, including cellular-level silicon to neuron connections, optical stimulation, and approaches to control inflammation. Overcoming the biophysical and biological challenges will enable effective high-density neural interfaces for stimulation and recording.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Communication within the nervous system is primarily through the rate and pattern of action potentials, and it is the number or spacing of these action potentials per unit time that code information. Thus, information can be introduced into the nervous system by inducing action potentials, or these action potentials can be read to obtain information from the nervous system [14].”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [14]
In the citing paper
“Peripheral nerve implants can also result in peripheral nerve injury. This can lead to Wallerian degeneration, neuropathic pain, and fibrosis, resulting in signal loss [14].”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [14]
In the citing paper
“The reported number of sensory perceptions and the locations evoked by intra-neural interfaces are very similar to those of the long-term extra-neural approaches, which led Grill et al. (2009) to conclude that the two approaches are equivalent.”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Grill et al. (2009)
In the citing paper
“A ramp pulse can be used to activate distal axons before closer ones (Grill and Mortimer, 1997; Grill et al., 2009)”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Grill et al., 2009
In the citing paper
“Hence, new therapeutic strategies for treating various refractory diseases through electrode-nerve interfaces have been developed, such as motor nerve stimulation and recording for controlling prosthetics and vagus nerve stimulation (VNS) for treating partial epilepsy, depression, heart failure (HF), and hypertension (1, 2).”
From Climbing-inspired twining electrodes using shape memory for peripheral nerve stimulation and recording (2019) · cites this paper as [2]
Citations
Cites
(1982) · Trends in Neurosciences · doi:10.1016/0166-2236(82)90076-5 · Cited by 9,089
Microglia-mediated neurotoxicity: uncovering the molecular mechanisms
Block, M. L., Zecca, L., & Hong, J.-S. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2038 · Cited by 4,110
Deep Brain Stimulation for Treatment-Resistant Depression
Mayberg, H. S., Lozano, A. M., Voon, V., McNeely, H. E., Seminowicz, D., Hamani, C., Schwalb, J. M., & Kennedy, S. H. (2005) · Neuron · doi:10.1016/j.neuron.2005.02.014 · Cited by 4,059
Henry, M. A. (1995) · The Journal of the American Dental Association · doi:10.14219/jada.archive.1995.0108 · Cited by 3,416
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Regeneration beyond the glial scar
Silver, J., & Miller, J. H. (2004) · Nature Reviews Neuroscience · doi:10.1038/nrn1326 · Cited by 3,078
Taussig, M. (2012) · Routledge eBooks · doi:10.4324/9780203397244 · Cited by 2,532
Krack, P., Batir, A., Van Blercom, N., Chabardes, S., Fraix, V., Ardouin, C., Koudsie, A., Limousin, P. D., Benazzouz, A., LeBas, J. F., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035275 · Cited by 2,249
Society for Neuroscience 2007 abstracts
Wishart, T. M., Paterson, J. M., Short, D. M., Meredith, S., Robertson, K., Sutherland, C. D., Cousin, M. A., Dutia, M. B., & Gillingwater, T. H. (2007) · Cited by 2,094
Which elements are excited in electrical stimulation of mammalian central nervous system: A review
Ranck, J. B. (1975) · Brain Research · doi:10.1016/0006-8993(75)90364-9 · Cited by 2,024
Research works printed but not linked: 7
- Vallbo AB, 1984, Hum. Neurobiol., 3, 3
- Rydevik B, 1990, Neural Prostheses Fundamental Studies, 85
- Hoffer JA, 1996, J. Rehabil. Res. Dev., 33, 145
- Bellamkonda RV, 2006, Biomaterials, 27, 3515
- Frosch MP, 2007, Basic Pathology
- 85. Deleted in press
- Shain W, 2003, IEEE Trans. Biomed. Eng., 11, 186
Cited by
Items 301–400 of 495
A first study on nanoporous tungsten recording electrodes for deep brain stimulation
Shuang, F., Deng, H., Shafique, A. B., Marsh, S., Treiman, D. M., Tsakalis, K. S., & Aifantis, K. E. (2019) · Materials Letters · doi:10.1016/j.matlet.2019.126885 · Cited by 13
Karczewski, A. M., Dingle, A. M., & Poore, S. O. (2021) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2021.711028 · Cited by 13
Stimulation of Neurons with Infrared Radiation
Zhao, K., Tan, X., Young, H. K., & Richter, C. (2016) · Springer eBooks · doi:10.1007/978-1-4939-1758-7_17 · Cited by 13
“The result is an overlap of stimulation fi elds when neighboring electrode contacts are used [ 1 ].”
MethodSoft‐Actuated Cuff Electrodes with Minimal Contact for Bidirectional Peripheral Interfaces
Moon, H., Park, B., Chou, N., Park, K., Lee, S., & Kim, S. (2024) · Advanced Materials · doi:10.1002/adma.202409942 · Cited by 15
Vascular remodeling in sheep implanted with endovascular neural interface
John, S. E., Donegan, S., Scordas, T. C. M., Qi, W., Sharma, P., Liyanage, K., Wilson, S., Birchall, I. E., Ooi, A. S. H., Oxley, T. J., et al. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac9a77 · Cited by 16
Colloidal Perspective on Targeted Drug Delivery to the Central Nervous System
Wang, W., Hassan, M. M., & Mao, G. (2023) · Langmuir · doi:10.1021/acs.langmuir.2c02949 · Cited by 12
Minaz, M., & Kurtoğlu, İ. Z. (2024) · Environmental Science and Pollution Research · doi:10.1007/s11356-024-33168-2 · Cited by 12
Stimulus outputs induced by subdural electrodes on the cervical spinal cord in monkeys
Kato, K., Nishihara, Y., & Nishimura, Y. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab63a3 · Cited by 12
Davey, C. J., Argyros, A., Fleming, S., & Solomon, S. G. (2015) · Applied Optics · doi:10.1364/ao.54.010068 · Cited by 12
Biotolerability of Intracortical Microelectrodes
Fernández, E., & Botella, P. (2018) · Advanced Biosystems · doi:10.1002/adbi.201700115 · Cited by 11
Bioelectric Interface Technologies in Cells and Organoids
Xue, Z., & Zhao, J. Z. (2023) · Advanced Materials Interfaces · doi:10.1002/admi.202300550 · Cited by 12
Jan, E., Pereira, F. N., Turner, D. L., & Kotov, N. A. (2011) · Journal of Materials Chemistry · doi:10.1039/c0jm01895c · Cited by 12
Morin, E. A., Tang, S., Rogers, K. L., & He, W. J. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b00929 · Cited by 12
Microelectrode Arrays: Architecture, Challenges and Engineering Solutions
Khudhair, D., Nahavandi, S., Garmestani, H., & Bhatti, A. (2017) · Series in bioengineering · doi:10.1007/978-981-10-3957-7_2 · Cited by 14
“The contraction of muscle resulting in stimulation of motor nerves is an example of external control [2].”
BackgroundKosta, P., Warren, D. J., & Lazzi, G. (2019) · Healthcare Technology Letters · doi:10.1049/htl.2018.5020 · Cited by 11
“Multichannel cuff electrode has been used to selectively activate the sciatic nerve, but these electrodes are found incapable of achieving reliable selective stimulation [7, 12].”
MethodSabetian, P., Sadat-Nejad, Y., & Yoo, P. B. (2021) · Scientific Reports · doi:10.1038/s41598-021-89624-3 · Cited by 11
Open-source Toolkit: Benchtop Carbon Fiber Microelectrode Array for Nerve Recording
Richie, J. M., Patel, P. R., Welle, E. J., Dong, T., Chen, L., Shih, A. J., & Chestek, C. A. (2021) · Journal of Visualized Experiments · doi:10.3791/63099 · Cited by 14
A Microclip Peripheral Nerve Interface (μcPNI) for Bioelectronic Interfacing with Small Nerves
Rowan, C. C., Graudejus, O., & Otchy, T. M. (2021) · Advanced Science · doi:10.1002/advs.202102945 · Cited by 12
Minimally Invasive & Long‐lasting Neural Probes from a Materials Perspective
Veronica, A., Li, Y., & Hsing, I. (2019) · Electroanalysis · doi:10.1002/elan.201800719 · Cited by 12
Biomaterials and computation: a strategic alliance to investigate emergent responses of neural cells
Sergi, P. N., & Cavalcanti‐Adam, E. A. (2017) · Biomaterials Science · doi:10.1039/c6bm00871b · Cited by 10
Plasmonic nano surface for neuronal differentiation and manipulation
Pandanaboina, S. C., Alghazali, K. M., Nima, Z. A., Alawajji, R. A., Sharma, K. D., Watanabe, F., Saini, V., Biris, A. S., & Srivatsan, M. (2019) · Nanomedicine Nanotechnology Biology and Medicine · doi:10.1016/j.nano.2019.102048 · Cited by 12
Virtuoso, A., Herrera‐Rincon, C., Papa, M., & Panetsos, F. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00389 · Cited by 11
Possibilities in bioelectronics: Super humans or science fiction?
Green, R. A. (2021) · APL Bioengineering · doi:10.1063/5.0079530 · Cited by 10
Chang, Y., Jang, J., Cho, J., Lee, J., Son, Y., Park, S., & Kim, C. (2022) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2022.3199455 · Cited by 9
“for the disorders because the technologies enable chronic neural monitoring and treatment [3], [4], [5].”
BackgroundA mm-Sized Free-Floating Wireless Implantable Opto-Electro Stimulation Device
Jia, Y., Gong, Y. P., Weber, A. J., Li, W., & Ghovanloo, M. (2020) · Micromachines · doi:10.3390/mi11060621 · Cited by 9
“For the in vivo assessment of the IMDs, cost-effective animal models, such as rodents, are often used [2,3].”
BackgroundDalrymple, A. N., & Mushahwar, V. K. (2020) · Journal of Medical Robotics Research · doi:10.1142/s2424905x20410032 · Cited by 9
Veith, A. P., Li, X., Modi, H., Abbaspour, A. R., Luan, L., Xie, C., & Baker, A. B. (2021) · Biomaterials · doi:10.1016/j.biomaterials.2021.120924 · Cited by 9
Valero-Sarmiento, J. M., Reynolds, J., Krystal, A. D., & Bozkurt, A. Y. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2772844 · Cited by 9
“Existing commercial wireless EEG systems [15]–[19] are either too bulky or heavy causing limitations related to mobility and behavioral disturbance.”
BackgroundA data-driven polynomial approach to reproduce the scar tissue outgrowth around neural implants
Sergi, P. N., del Valle, J., de la Oliva, N., Micera, S., & Navarro, X. (2020) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-020-06396-4 · Cited by 9
Taghlabi, K. M., Cruz-Garza, J. G., Hassan, T., Potnis, O., Bhenderu, L. S. S., Guerrero, J. R., Whitehead, R. E., Wu, Y. C., Luan, L., Xie, C., et al. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad200f · Cited by 9
“Peripheral nerve injury, which can lead to Wallerian degeneration and fibrosis causing signal loss, is also a design concern [10].”
BackgroundMultichannel cuff electrodes for peripheral nerve stimulation and recording
Brunton, E., Blau, C. W., & Nazarpour, K. (2016) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2016.7844730 · Cited by 9
“The exchange of information across the neural interface can occur in two directions via stimulation or recording from nerve fibers [2].”
BackgroundNeural interfacing biomaterials coated with the firmly tethered neuro-specific lipid bilayer
Hasan, M. L., Kim, G. E., Elnaggar, M. A., Yang, D. H., & Joung, Y. K. (2023) · Applied Surface Science · doi:10.1016/j.apsusc.2023.156424 · Cited by 9
Challenges in Neurorehabilitation and Neural Engineering
Caramenti, M., Bartenbach, V., Gasperotti, L., da Fonseca, L. O., Berger, T. W., & Pons, J. L. (2015) · Biosystems & biorobotics · doi:10.1007/978-3-319-24901-8_1 · Cited by 11
Stimulation of the Spinal Cord for the Control of Walking
Dalrymple, A. N., & Mushahwar, V. K. (2017) · Series on bioengineering and biomedical engineering · doi:10.1142/9789813207158_0025 · Cited by 10
Maeng, L. Y., Murillo, M. F., Mu, M., Lo, M.-C., de la Rosa, M., O’Brien, J. M., Freeman, D. K., & Widge, A. S. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aafc72 · Cited by 9
“For one, it is smaller than microbattery-powered neurostimulators that offer similar functionality (Schulman 2008, Grill et al 2009).”
BackgroundKilohertz Electrical Stimulation Nerve Conduction Block: Effects of Electrode Material
Patel, Y., Kim, B. S., & Butera, R. J. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2737954 · Cited by 8
“dissolution [11], [12].”
Optimizing a novel nerve cuff electrode to record bidirectional neural activity
Sabetian, P., & Yoo, P. B. (2019) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2019.8717079 · Cited by 8
“However, the wide spread clinical use of nerve electrodes as a means of recording peripheral nerve activity has been limited [7].”
BackgroundReply to Diggles et al. (2011): Ecology and welfare of aquatic animals in wild capture fisheries
Torgersen, T., Bracke, M. B. M., & Kristiansen, T. (2011) · Reviews in Fish Biology and Fisheries · doi:10.1007/s11160-011-9221-y · Cited by 18
Multi-unit recording with iridium oxide modified stereotrodes in Drosophila melanogaster
Zhong, C., Zhang, Y., He, W. J., Wei, P., Lu, Y., Zhu, Y., Liu, L., & Wang, L. (2013) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2013.11.013 · Cited by 7
Finding the Location of Axonal Activation by a Miniature Magnetic Coil
Ye, H. (2022) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2022.932615 · Cited by 7
“, 2004), glial scar formation around the electrode (Polikov et al., 2005; Grill et al., 2009), oxidization of the electrode, and other bioelectric changes around the electrode, such as accumulation of extracellular potassium during deep brain stimulation (Shin and Carlen, 2008).”
BackgroundAccelerating neurotechnology development using an Agile methodology
Thota, A. K., & Jung, R. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2024.1328540 · Cited by 7
“The material considerations for fabricating electrodes depend on the stimulation and/or recording function of the PNI (Cogan, 2008; Grill et al., 2009).”
BackgroundEvent detection and classification from multimodal time series with application to neural data
Sadras, N., Pesaran, B., & Shanechi, M. M. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad3678 · Cited by 9
Payne, S. C., Wiedmann, N. M., Eiber, C. D., Wong, A. W., Senn, P., Osborne, P. B., Keast, J. R., & Fallon, J. B. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.619275 · Cited by 8
Ahmadipour, P., Sani, O. G., Pesaran, B., & Shanechi, M. M. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad1053 · Cited by 16
Biomedical engineering in heart-brain medicine: A review
Katona, P. G. (2010) · Cleveland Clinic Journal of Medicine · doi:10.3949/ccjm.77.s3.08 · Cited by 8
Electrode–Neural Tissue Interactions: Immune Responses, Current Technologies, and Future Directions
Kim, G. B., Fattahi, P., & Abidian, M. R. (2013) · Wiley eBooks · doi:10.1002/9783527649600.ch19 · Cited by 6
3D Expandable Microwire Electrode Arrays Made of Programmable Shape Memory Materials
Zhao, R., Liu, X., Lu, Y., Ren, C., Mehrsa, A., Komiyama, T., & Kuzum, D. (2018) · Technical digest - International Electron Devices Meeting/Technical digest · doi:10.1109/iedm.2018.8614549 · Cited by 6
Real-time decoding of bladder pressure from pelvic nerve activity
Lubba, C. H., Mitrani, E., Hokanson, J., Grill, W. M., & Schultz, S. R. (2017) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2017.8008427 · Cited by 7
Self-citationGrinin, L. E., Леонидович, Г. А., & Korotayev, A. (2024) · World-systems evolution and global futures · doi:10.1007/978-3-031-56764-3_10 · Cited by 9
Lee, J. Y., Kim, T., Cho, S., Shin, J. H., Yeo, W., Kim, T. S., & Yu, K. J. (2025) · Bioactive Materials · doi:10.1016/j.bioactmat.2025.02.006 · Cited by 11
Polysaccharide Hydrogel Incorporated Carbon Nanofiber Microelectrode for Designing Neural Interfaces
T., A. T. A., & Badiger, M. V. (2019) · Journal of Bionic Engineering · doi:10.1007/s42235-019-0056-x · Cited by 6
Amiri, M., Nazari, S., Jafari, A. H., & Makkiabadi, B. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e13766 · Cited by 6
“The classical approach of the BMI algorithms includes recording electrodes to extract motor signal [19] and decoding neural response of motor in order to reveal moving target [20,21].”
MethodFlexible Electrode for Implantable Neural Devices
Tsang, W. M., & Je, M. (2014) · Springer eBooks · doi:10.1007/978-1-4614-8151-5_6 · Cited by 6
Gough, Z., Chaminade, C., Barclay-Monteith, P., Kallinen, A., Lei, W., Ganesan, R., Grace, J., & McKenzie, D. R. (2017) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2017.01.010 · Cited by 7
Solvent-Free Strategy To Encapsulate Degradable, Implantable Metals in Silk Fibroin
Hawker, M. J., Guo, C., Omenetto, F. G., & Kaplan, D. L. (2018) · ACS Applied Bio Materials · doi:10.1021/acsabm.8b00498 · Cited by 7
Insulation of Carbon Nanotube Yarn Electrodes for Intrafascicular Neural Stimulation and Recording
Su, J., Zhang, X., Li, M. N., Gao, T., Wang, R., Chai, X. Y., Zhang, D. G., Zhang, X. H., & Sui, X. (2019) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2019.8716984 · Cited by 7
Sergi, P. N. (2020) · Applied Sciences · doi:10.3390/app10186372 · Cited by 6
An FPGA-Based Neuron Activity Extraction Unit for a Wireless Neural Interface
Chowdhury, M. H., Elyahoodayan, S., Song, D. B., & Cheung, R. C. C. (2020) · Electronics · doi:10.3390/electronics9111834 · Cited by 6
Cut wires: The Electrophysiology of Regenerated Tissue
Lowe, A. L., & Thakor, N. V. (2021) · Bioelectronic Medicine · doi:10.1186/s42234-021-00062-y · Cited by 6
“It is still a technological challenge to longitudinally record from an implanted interface (Grill et al., 2009).”
BackgroundMillevolte, A. X. T., Dingle, A. M., Ness, J. P., Novello, J., Zeng, W., Lü, Y., Minor, R. L., Nemke, B. W., Markel, M. D., Suminski, A. J., et al. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.613844 · Cited by 6
“, the ability of a peripheral neural interface (PNI) to selectively stimulate or record from individual nerves – is a critical parameter inherently linked to the degrees of freedom a PNI is capable of controlling, as well as the differentiation between motor and sensory signals (Grill et al., 2009; Micera and Navarro,…”
BackgroundScale of Carbon Nanomaterials Affects Neural Outgrowth and Adhesion
Franca, E., Jao, P. F., Fang, S.-P., Alagapan, S., Pan, L., Yoon, J. H., Yoon, Y.-K., & Wheeler, B. C. (2016) · IEEE Transactions on NanoBioscience · doi:10.1109/tnb.2016.2519505 · Cited by 7
“2519505 neural microelectrodes, there remain several serious challenges including the loss of physical and electrical contact between microelectrodes and neural tissue over time [4].”
BackgroundLiu, R., Azabou, M., Dabagia, M., Xiao, J., & Dyer, E. L. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2022.06.10.495595 · Cited by 6
Lee, S. W., & Fried, S. I. (2022) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2021.0019 · Cited by 5
A steady-state mathematical model for an EOS capacitor: The effect of the size exclusion
Michele, F. D., Rubino, B., & Sampalmieri, R. (2016) · Networks and Heterogeneous Media · doi:10.3934/nhm.2016011 · Cited by 5
“The feasibility of totally implantable devices in the brain is discussed in [12], [28], and [31] (see also [20] and [29] for a complete review).”
BackgroundAdewole, D. O., Struzyna, L. A., Harris, J. P., Nemes, A. D., Burrell, J. C., Petrov, D., Kraft, R. H., Chen, H. I., Serruya, M. D., Wolf, J. A., et al. (2018) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/333526 · Cited by 6
Grinin, L. E., & Леонидович, Г. А. (2015) · Figshare · doi:10.5281/zenodo.1210435 · Cited by 5
Sergi, P. N., Jensen, W., & Yoshida, K. (2022) · Applied Sciences · doi:10.3390/app12188938 · Cited by 4
Interface properties of nanostructured carbon-coated biological implants: an overview
Bartoli, M., Cardano, F., Piatti, E., Lettieri, S., Fin, A., & Tagliaferro, A. (2024) · Beilstein Journal of Nanotechnology · doi:10.3762/bjnano.15.85 · Cited by 4
Stimulation of peripheral nerves using conductive hydrogel electrodes
Gilmour, A. D., Goding, J. A., Robles, U. A. A., Staples, N. A., Byrnes‐Preston, P., Morley, J. W., Lovell, N. H., Chew, D. J., & Green, R. A. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513628 · Cited by 5
“Two major challenges are associated with chronically interfacing electrode arrays in the PNS for nerve block; mechanical mismatch between stiff electrodes and soft neural tissue, and charge imbalance and electrode degradation as a result of chronic high-frequency stimulation [6-10].”
BackgroundAnderson, H. E., Schaller, K., Caldwell, J. H., & Weir, R. F. F. (2019) · Neuroscience Letters · doi:10.1016/j.neulet.2019.05.010 · Cited by 4
“Current invasive methods for interfacing with the nervous system suffer from limitations in number and specificity of input and output channels, nerve damage from penetrating electrodes and scarring that limits functionality over time.[1,2] The deployment of optogenetic proteins in peripheral nerves could form the bas…”
BackgroundA Focused Review of Neural Recording and Stimulation Techniques With Immune-Modulatory Targets
Carnevale, L., Perrotta, M., & Lembo, G. (2021) · Frontiers in Immunology · doi:10.3389/fimmu.2021.689344 · Cited by 4
Neural stimulation technologies
Andersen, T., Bó, A. P. L., Watkins, G. D., Mohammad, S. S., & McEwan, A. L. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-820594-5.00011-3 · Cited by 6
Wang, M., & Guo, L. (2020) · Springer eBooks · doi:10.1007/978-3-030-41854-0_4 · Cited by 4
Intracranialbrain–computer interfaces for communication and control
Jarosiewicz, B., & Hochberg, L. R. (2014) · Cambridge University Press eBooks · doi:10.1017/cbo9780511995583.042 · Cited by 4
Co-evolution of neurotechnology and AI: ethical challenges and regulatory approaches
Shenderyuk-Zhidkov, A., Maksimenko, V., Hramov, A., & Federal State Autonomous Institution "Digital Industrial Technologies Moscow, R. (2025) · Izvestiya VUZ Applied Nonlinear Dynamics · doi:10.18500/0869-6632-003196 · Cited by 4
Technologies in clinical neurophysiology for brain-body interfacing: IFCN handbook chapter
Cimolato, A., Sparapani, A., & Raspopović, S. (2026) · Clinical Neurophysiology · doi:10.1016/j.clinph.2026.2111913 · Cited by 3
Generation of axolotl hematopoietic chimeras
Lopez, D., & Scott, E. W. (2015) · Journal of Biological Methods · doi:10.14440/jbm.2015.43 · Cited by 3
State-of-the-Art Technology on Highly Miniaturized Free-Floating Neural Implants
Khalifa, A., & Etienne‐Cummings, R. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_114 · Cited by 3
Kozai, T. D. Y., Marzullo, T., Hooi, F. M., Langhals, N. B., Majewska, A. K., Brown, E. B., & Kipke, D. R. (2010) · Deep Blue (University of Michigan) · doi:10.1088/1741-2560/7/4 · Cited by 3
Neurointerfaces: Review and development
Rechkunov, S. N., Prinz, A. V., Seleznev, V. A., Golod, S. V., Soots, R. A., Ivanov, A. I., Ratushnyak, A. S., & Prinz, V. Y. (2015) · Russian Journal of Genetics Applied Research · doi:10.1134/s2079059715060143 · Cited by 3
“One of the major research tasks is to develop effec tive interface between neuronal population and outer world (Rutten, 2002; Grill et al., 2009).”
BackgroundGueli, C., Vomero, M., Sharma, S., & Stieglitz, T. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8856960 · Cited by 3
“Favorable interaction with the target tissue and reactions at electrode’s interface are major factors for the success of an implanted medical device or its failure [3, 4].”
BackgroundGbadamosi, O. K. (2021) · The Journal of Basic and Applied Zoology · doi:10.1186/s41936-021-00256-5 · Cited by 3
Some Mechanical Constraints to the Biomimicry with Peripheral Nerves
Sergi, P. N. (2023) · Biomimetics · doi:10.3390/biomimetics8070544 · Cited by 3
Influence of bio-coatings on the recording performance of neural electrodes
Chow, W. W. Y., Herwik, S., Kisban, S., Ruther, P., Neves, H. P., Oscarsson, S. O., & Göthelid, E. (2014) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2013-0017 · Cited by 3
Chemical Synthesis of Polypyrrole Nanotubes for Neural Microelectrodes
Kojabad, Z. D., & Shojaosadati, S. A. (2015) · Procedia Materials Science · doi:10.1016/j.mspro.2015.11.014 · Cited by 3
Liquid Metal Enabled Injectable Biomedical Electronics
Liu, J., & Yi, L. (2018) · Springer series in biomaterials science and engineering · doi:10.1007/978-981-10-5607-9_8 · Cited by 3
Human psychophysics of direct cortical stimulation of somatosensory cortex
Cronin, J. A. (2018) · ResearchWorks at the University of Washington (University of Washington) · Cited by 4
Sharpened and mechanically durable carbon fiber electrode arrays for neural interfacingPreprint
Welle, E. J., Woods, J. E., Jiman, A. A., Richie, J. M., Bottorff, E. C., Ouyang, Z., Seymour, J. P., Patel, P. R., Bruns, T. M., & Chestek, C. A. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.01.21.427697 · Cited by 5
“However current interfaces have limited long-term viability due to electrode material failure [23], [24] and significant scarring [25], [26].”
BackgroundAdewole, D. O., Struzyna, L. A., Harris, J. P., Nemes, A. D., Burrell, J. C., Petrov, D., Kraft, R. H., Chen, H.-C. I., Wolf, J. A., Serruya, M. D., et al. (2018) · SSRN Electronic Journal · doi:10.2139/ssrn.3189383 · Cited by 6
Lam, D., Lindemann, M., Yang, K., Liu, D. X., Ludwig, K. A., & Shoffstall, A. J. (2023) · eNeuro · doi:10.1523/eneuro.0305-23.2023 · Cited by 3
“Applications with implanted EMG leads face similar challenges where a sustained foreign body response impacts the signal quality over time (Grill et al., 2009; Gao et al., 2022).”
BackgroundAbbott, J., Jeakle, E. N., Wu, Y., Smith, T. J., Geramifard, N., Chakraborty, B., Khajehzadeh, M., Dhananjayan, S., Hernandez-Reynoso, A. G., Pancrazio, J. J., et al. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/adee49 · Cited by 2
Zhang, B., You, X., Liu, Y. P., Xu, J., & Xu, S. (2026) · Sensors · doi:10.3390/s26020576 · Cited by 3
“Nonetheless, mechanical mismatch between the electrode and neural tissue can still induce fibrotic encapsulation [83], motivating the development of all-polymer cuffs whose mechanical properties more closely match those of peripheral nerves to attenuate chronic inflammatory responses [84].”
3D Cell Culture Systems for the Development of Neural Interfaces
Syed, O., Chapman, C., Vallejo‐Giraldo, C., Genta, M., Goding, J. A., Kanelos, E., & Green, R. A. (2020) · Springer eBooks · doi:10.1007/978-3-030-41854-0_8 · Cited by 2
Zhou, R., Mou, Z., Yang, D., & Wang, X. (2021) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-021-02475-y · Cited by 3
On the Relationship Between Fascicle Diameter and Perineurium Thickness in the Ulnar Nerve of Pigs
Andreis, F. R., Metcalfe, B., Janjua, T. A. M., Fazan, V. P. S., Jensen, W., Meijs, S., & Nielsen, T. N. (2023) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner52421.2023.10123782 · Cited by 2
“The application of electrical stimulation to modulate peripheral nerve activity can be used to restore motor and sensory function in impaired systems [1].”
BackgroundA Pilot In Vivo Study of Flexible Fully Polymeric Nerve Cuff Electrodes*
Cuttaz, E. A., Syed, O., Chapman, C. A. R., Goding, J. A., Bailey, Z., Lara, R. P., & Green, R. A. (2023) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc40787.2023.10341006 · Cited by 3
“Current devices have been successful in providing stimulation and recording, however conventional planar metals used in these devices have been associated with two main limitations[4].”
BackgroundLaser Welding of Micro-Wire Stent Electrode as a Minimally Invasive Endovascular Neural Interface
Wen, B., Shen, L., & Kang, X. (2024) · Micromachines · doi:10.3390/mi16010021 · Cited by 3
Wen, B., Su, L., Zhang, Y., Wang, A., Zhao, H., Wu, J., Gan, Z., Zhang, L., & Kang, X. (2025) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/adc266 · Cited by 2
Horiguchi, Y., Wu, H., Murata, M., Matsumoto, H., Ohnuki, H., & Endo, H. (2025) · Fish Physiology and Biochemistry · doi:10.1007/s10695-025-01488-w · Cited by 2
Developing Chitosan-based Biomaterials for Brain Repair and Neuroprosthetics
Cao, Z. H. (2010) · Cited by 3
Metadata
- Authors
- Grill, W. M., Norman, S. E., & Bellamkonda, R. V.
- Affiliations
- Duke University (US)
- Georgia Institute of Technology (US)
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2009-08-01
- Volume
- 11
- Issue
- 1
- Pages
- 1-24
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2118756387
- Semantic Scholar
- 46b193b47ceebfd3b792cc3da8f142b50b7cffb3
- Cited by
- 488
- References
- 148
- Citations by year
- 2026: 14 · 2025: 15 · 2024: 26 · 2023: 31 · 2022: 24 · 2021: 39 · 2020: 37 · 2019: 43 · 2018: 35 · 2017: 43 · 2016: 34 · 2015: 35 · 2014: 25 · 2013: 29 · 2012: 17
- FWCI
- 1.67
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Annual Review of Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Social Sciences › Education › Undergraduate Neuroscience Education and Research
- Keywords
- neural interfaces, neural recording, neurostimulation, electrode design, electrode geometry, stimulation waveform, implant materials, surface modification, selectivity, peripheral nerves, spinal cord, optical stimulation, inflammation control
- MeSH terms
- Animals, Biophysics, Electric Stimulation, Electrodes, Implanted, Ganglia, Spinal, Humans, Inflammation, Models, Biological, Models, Neurological, Nerve Net, Neurons, Peripheral Nervous System, Optics and Photonics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.