Implanted Neural Interfaces: Biochallenges and Engineered Solutions
The DOI matches its Crossref record; 147 of the 148 references it cites were found in a registry or an index.
Abstract
Neural interfaces are connections that enable two-way exchange of information with the nervous system. These connections can occur at multiple levels, including with peripheral nerves, with the spinal cord, or with the brain; in many instances, fundamental biophysical and biological challenges are shared across these levels. We review these challenges, including selectivity, stability, resolution versus invasiveness, implant-induced injury, and the host-interface response. Subsequently, we review the engineered solutions to these challenges, including electrode designs and geometry, stimulation waveforms, materials, and surface modifications. Finally, we consider emerging opportunities to improve neural interfaces, including cellular-level silicon to neuron connections, optical stimulation, and approaches to control inflammation. Overcoming the biophysical and biological challenges will enable effective high-density neural interfaces for stimulation and recording.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Communication within the nervous system is primarily through the rate and pattern of action potentials, and it is the number or spacing of these action potentials per unit time that code information. Thus, information can be introduced into the nervous system by inducing action potentials, or these action potentials can be read to obtain information from the nervous system [14].”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [14]
In the citing paper
“Peripheral nerve implants can also result in peripheral nerve injury. This can lead to Wallerian degeneration, neuropathic pain, and fibrosis, resulting in signal loss [14].”
From Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review (2020) · cites this paper as [14]
In the citing paper
“The reported number of sensory perceptions and the locations evoked by intra-neural interfaces are very similar to those of the long-term extra-neural approaches, which led Grill et al. (2009) to conclude that the two approaches are equivalent.”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Grill et al. (2009)
In the citing paper
“A ramp pulse can be used to activate distal axons before closer ones (Grill and Mortimer, 1997; Grill et al., 2009)”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Grill et al., 2009
In the citing paper
“Hence, new therapeutic strategies for treating various refractory diseases through electrode-nerve interfaces have been developed, such as motor nerve stimulation and recording for controlling prosthetics and vagus nerve stimulation (VNS) for treating partial epilepsy, depression, heart failure (HF), and hypertension (1, 2).”
From Climbing-inspired twining electrodes using shape memory for peripheral nerve stimulation and recording (2019) · cites this paper as [2]
Citations
Cites
(1982) · Trends in Neurosciences · doi:10.1016/0166-2236(82)90076-5 · Cited by 9,089
Microglia-mediated neurotoxicity: uncovering the molecular mechanisms
Block, M. L., Zecca, L., & Hong, J.-S. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2038 · Cited by 4,110
Deep Brain Stimulation for Treatment-Resistant Depression
Mayberg, H. S., Lozano, A. M., Voon, V., McNeely, H. E., Seminowicz, D., Hamani, C., Schwalb, J. M., & Kennedy, S. H. (2005) · Neuron · doi:10.1016/j.neuron.2005.02.014 · Cited by 4,059
Henry, M. A. (1995) · The Journal of the American Dental Association · doi:10.14219/jada.archive.1995.0108 · Cited by 3,416
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Regeneration beyond the glial scar
Silver, J., & Miller, J. H. (2004) · Nature Reviews Neuroscience · doi:10.1038/nrn1326 · Cited by 3,078
Taussig, M. (2012) · Routledge eBooks · doi:10.4324/9780203397244 · Cited by 2,532
Krack, P., Batir, A., Van Blercom, N., Chabardes, S., Fraix, V., Ardouin, C., Koudsie, A., Limousin, P. D., Benazzouz, A., LeBas, J. F., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa035275 · Cited by 2,249
Society for Neuroscience 2007 abstracts
Wishart, T. M., Paterson, J. M., Short, D. M., Meredith, S., Robertson, K., Sutherland, C. D., Cousin, M. A., Dutia, M. B., & Gillingwater, T. H. (2007) · Cited by 2,094
Which elements are excited in electrical stimulation of mammalian central nervous system: A review
Ranck, J. B. (1975) · Brain Research · doi:10.1016/0006-8993(75)90364-9 · Cited by 2,024
Research works printed but not linked: 7
- Vallbo AB, 1984, Hum. Neurobiol., 3, 3
- Rydevik B, 1990, Neural Prostheses Fundamental Studies, 85
- Hoffer JA, 1996, J. Rehabil. Res. Dev., 33, 145
- Bellamkonda RV, 2006, Biomaterials, 27, 3515
- Frosch MP, 2007, Basic Pathology
- 85. Deleted in press
- Shain W, 2003, IEEE Trans. Biomed. Eng., 11, 186
Cited by
Yuk, H., Lu, B., & Zhao, X. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00595h · Cited by 2,108
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
Stretchable silicon nanoribbon electronics for skin prosthesis
Kim, J., Lee, M., Shim, H. J., Ghaffari, R., Cho, H. R., Son, D., Jung, Y. H., Soh, M., Choi, C., Jung, S., et al. (2014) · Nature Communications · doi:10.1038/ncomms6747 · Cited by 1,435
Kozai, T. D. Y., Langhals, N. B., Patel, P. R., Deng, X., Zhang, H., Smith, K. L., Lahann, J., Kotov, N. A., & Kipke, D. R. (2012) · Nature Materials · doi:10.1038/nmat3468 · Cited by 721
Enhanced Differentiation of Human Neural Stem Cells into Neurons on Graphene
Park, S. Y., Park, J., Sim, S. H., Sung, M. G., Kim, K. S., Hong, B. H., & Hong, S. (2011) · Advanced Materials · doi:10.1002/adma.201101503 · Cited by 703
Graphene: Promises, Facts, Opportunities, and Challenges in Nanomedicine
Mao, H. Y., Laurent, S., Chen, W., Akhavan, O., Imani, M., Ashkarran, A. A., & Mahmoudi, M. (2013) · Chemical Reviews · doi:10.1021/cr300335p · Cited by 701
Flexible Hybrid Electronics for Digital Healthcare
Ma, Y., Zhang, Y., Cai, S., Han, Z., Liu, X., Wang, F., Cao, Y., Wang, Z., Li, H., Chen, Y., et al. (2020) · Advanced Materials · doi:10.1002/adma.201902062 · Cited by 620
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Wireless Power Transfer Strategies for Implantable Bioelectronics
Agarwal, K., Jegadeesan, R., Guo, Y.-X., & Thakor, N. V. (2017) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2683520 · Cited by 540
Hassler, C., Boretius, T., & Stieglitz, T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22169 · Cited by 501
Multifunctional “Hydrogel Skins” on Diverse Polymers with Arbitrary Shapes
Yu, Y., Yuk, H., Parada, G. A., Wu, Y., Liu, X., Nabzdyk, C. S., Youcef‐Toumi, K., Zang, J., & Zhao, X. (2019) · Advanced Materials · doi:10.1002/adma.201807101 · Cited by 482
Ultrasonic neuromodulation by brain stimulation with transcranial ultrasound
Tufail, Y., Yoshihiro, A., Pati, S., Li, M. M., & Tyler, W. J. (2011) · Nature Protocols · doi:10.1038/nprot.2011.371 · Cited by 473
“The primary disadvantage of using electrodes for intact brain circuit stimulation is that they require direct contact with neural tissue and necessitate surgical procedures, which triggers deleterious processes such as inflammation, bleeding, cell death and gliosi”
BackgroundWu, X., Zhang, Y., Takle, K., Bilsel, O., Li, Z., Lee, H., Zhang, Z., Li, D., Fan, W., Duan, C., et al. (2016) · ACS Nano · doi:10.1021/acsnano.5b06383 · Cited by 449
Moshayedi, P., Ng, G., Kwok, J. C. F., Yeo, G. S. H., Bryant, C. E., Fawcett, J. W., Franze, K., & Guck, J. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.01.038 · Cited by 394
Ellis, T., Yildiz, H. Y., López-Olmeda, J., Spedicato, M. T., Tort, L., Øverli, Ø., & Martins, C. I. M. (2012) · Fish Physiology and Biochemistry · doi:10.1007/s10695-011-9568-y · Cited by 361
Restoring sensorimotor function through intracortical interfaces: progress and looming challenges
Bensmaia, S. J., & Miller, L. E. (2014) · Nature Reviews Neuroscience · doi:10.1038/nrn3724 · Cited by 368
What is environmental stress? Insights from fish living in a variable environment
Schulte, P. M. (2014) · Journal of Experimental Biology · doi:10.1242/jeb.089722 · Cited by 334
Soft Materials in Neuroengineering for Hard Problems in Neuroscience
Jeong, J.-W., Shin, G., Park, S. I., Yu, K. J., Xu, L., & Rogers, J. A. (2015) · Neuron · doi:10.1016/j.neuron.2014.12.035 · Cited by 333
Zhang, Y., Zheng, N., Cao, Y., Wang, F., Wang, P., Ma, Y., Lu, B., Hou, G., Fang, Z., Liang, Z., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw1066 · Cited by 314
Park, S., Yuk, H., Zhao, R., Yim, Y. S., Woldeghebriel, E. W., Kang, J., Canales, A., Fink, Y., Choi, G. B., Zhao, X., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-23802-9 · Cited by 312
Muscarine, imidazole, oxazole, and thiazole alkaloids
Jin, Z. (2011) · Natural Product Reports · doi:10.1039/c0np00074d · Cited by 311
Charthad, J., Weber, M. J., Chang, T. C., & Arbabian, A. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2427336 · Cited by 245
“W IRELESSLY POWERED, highly miniaturized implantable medical devices (IMDs) can play a crucial role in eliminating the invasiveness and discomfort caused by batteries and wires in most traditional implants [1], [2].”
BackgroundPotter, K. A., Buck, A. C., Self, W. K., & Capadona, J. R. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/4/046020 · Cited by 239
Flexible inorganic bioelectronics
Chen, Y., Zhang, Y., Liang, Z., Cao, Y., Han, Z., & Feng, X. (2020) · npj Flexible Electronics · doi:10.1038/s41528-020-0065-1 · Cited by 227
Zhou, T., Hong, G., Fu, T.-M., Yang, X., Schuhmann, T. G., Viveros, R. D., & Lieber, C. M. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1705509114 · Cited by 227
Functional Electrical Stimulation and Spinal Cord Injury
Ho, C. H., Triolo, R. J., Elias, A. L., Kilgore, K. L., DiMarco, A. F., Bogie, K., Vette, A. H., Audu, M. L., Kobetic, R., Chang, S. R., et al. (2014) · Physical Medicine and Rehabilitation Clinics of North America · doi:10.1016/j.pmr.2014.05.001 · Cited by 203
“Beyond this, several strategies have been undertaken to modify the surface properties of electrodes to improve the interactions that take place with surrounding tissue and reduce glial scar formation.(14) When developing new electrodes, arrays, and coatings, in vitro testing may be used initially to screen the cellula…”
MethodSimitzi, C., Ranella, A., & Stratakis, E. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.01.023 · Cited by 204
“in the form of aligned nanofibers, could be used to guide neural processes in peripheral nerve electrodes [49].”
BackgroundRecent Advances in Materials, Devices, and Systems for Neural Interfaces
Won, S. M., Song, E., Zhao, J., Li, J., Rivnay, J., & Rogers, J. A. (2018) · Advanced Materials · doi:10.1002/adma.201800534 · Cited by 206
Actively controlled release of Dexamethasone from neural microelectrodes in a chronic in vivo study
Boehler, C., Kleber, C., Martini, N., Xie, Y., Dryg, I., Stieglitz, T., Hofmann, U. G., & Asplund, M. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.03.019 · Cited by 196
Ramekers, D., Versnel, H., Strahl, S. B., Smeets, E. M., Klis, S. F. L., & Grolman, W. (2014) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-013-0440-x · Cited by 198
Electrodeposited polypyrrole/carbon nanotubes composite films electrodes for neural interfaces
Lu, Y., Li, T., Zhao, X., Li, M., Cao, Y., Yang, H., & Duan, Y. Y. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.03.022 · Cited by 191
“Development of effective high density neural interface for longterm stimulation and recording in vivo remains a great challenge [44].”
BackgroundBiomaterials‐Based Electronics: Polymers and Interfaces for Biology and Medicine
Muskovich, M., & Bettinger, C. J. (2012) · Advanced Healthcare Materials · doi:10.1002/adhm.201200071 · Cited by 182
Kozai, T. D. Y., Marzullo, T. C., Hooi, F., Langhals, N. B., Majewska, A. K., Brown, E. B., & Kipke, D. R. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/4/046011 · Cited by 184
“…of erythrocytes, clotting factors and inflammatory factors from disrupted blood vessels which facilitate the recruitment of activated microglia and a broad region of astrocyte activation around the inserted probe (Schwartz et al 2006, Szarowski et al 2003, Turner et al 1999, Grill et al 2009).”
BackgroundBiomimetic approaches to bionic touch through a peripheral nerve interface
Saal, H. P., & Bensmaia, S. J. (2015) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2015.06.010 · Cited by 179
Large enhancement in neurite outgrowth on a cell membrane-mimicking conducting polymer
Zhu, B., Luo, S.-C., Zhao, H., Lin, H.-A., Sekine, J., Nakao, A., Chen, C., Yamashita, Y., & Yu, H.-H. (2014) · Nature Communications · doi:10.1038/ncomms5523 · Cited by 171
Long-term usability and bio-integration of polyimide-based intra-neural stimulating electrodes
Wurth, S., Capogrosso, M., Raspopovic, S., Gandar, J., Federici, G., Kinany, N., Cutrone, A., Piersigilli, A., Pavlova, N., Guiet, R., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.01.014 · Cited by 176
Biointegrated and Wirelessly Powered Implantable Brain Devices: A Review
Das, R., Moradi, F., & Heidari, H. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.2966920 · Cited by 172
Biocompatibility of intracortical microelectrodes: current status and future prospects
Marin, C. (2010) · Frontier in Neuroengineering · doi:10.3389/fneng.2010.00008 · Cited by 160
“The damaged tissue assumes a state of emergency, rapidly changing its gene expression and stimulating nearby microglia and astrocytes (Lee et al., 2005; Polikov et al., 2005; Biran et al., 2007; Grill et al., 2009; McConnell et al., 2009).”
InfluentialA biofunctionalization scheme for neural interfaces using polydopamine polymer
Kang, K., Choi, I. S., & Nam, Y. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.05.028 · Cited by 158
Apollo, N. V., Maturana, M. I., Tong, W., Nayagam, D. A. X., Shivdasani, M. N., Foroughi, J., Wallace, G. G., Prawer, S., Ibbotson, M. R., & Garrett, D. J. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201500110 · Cited by 152
Gallium nitride is biocompatible and non-toxic before and after functionalization with peptides
Jewett, S. A., Makowski, M. S., Andrews, B., Manfra, M. J., & Ivanisevic, A. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.09.038 · Cited by 171
“The literature is equally rich in studies centered on fundamental and applied aspects of using electrical stimuli to probe and guide neuronal function [3].”
BackgroundAcute human brain responses to intracortical microelectrode arrays: challenges and future prospects
Fernández, E., Greger, B., House, P. A., Aranda, I., Botella, C., Albisua, J., Soto-Sánchez, C., Alfaro, A., & Normann, R. A. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00024 · Cited by 141
“NEUROENGINEERING HYPOTHESIS AND THEORY ARTICLE published: 21 July 2014 doi: 10.3389/fneng.2014.00024 Acute human brain responses to intracortical microelectrode arrays: challenges and future prospects”
BackgroundInfluentialImplantable microcoils for intracortical magnetic stimulation
Lee, S. W., Fallegger, F., Casse, B. D. F., & Fried, S. I. (2016) · Science Advances · doi:10.1126/sciadv.1600889 · Cited by 151
Neural stimulation with optical radiation
Richter, C., Matic, A. I., Wells, J. D., Jansen, D., & Walsh, J. T. (2010) · Laser & Photonics Review · doi:10.1002/lpor.200900044 · Cited by 162
Beyond the brain: Optogenetic control in the spinal cord and peripheral nervous system
Montgomery, K. L., Iyer, S. M., Christensen, A. J., Deisseroth, K., & Delp, S. L. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aad7577 · Cited by 147
Predicting the effects of anthropogenic noise on fish reproduction
de Jong, K., Forland, T. N., Amorim, M. C. P., Rieucau, G., Slabbekoorn, H., & Sivle, L. D. (2020) · Reviews in Fish Biology and Fisheries · doi:10.1007/s11160-020-09598-9 · Cited by 161
Implantable intracortical microelectrodes: reviewing the present with a focus on the future
Wang, Y., Yang, X., Zhang, X., Wang, Y., & Pei, W. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00451-6 · Cited by 163
Transient and selective suppression of neural activity with infrared light
Duke, A. R., Jenkins, M. W., Lu, H., McManus, J. M., Chiel, H. J., & Jansen, D. (2013) · Scientific Reports · doi:10.1038/srep02600 · Cited by 144
Biohybrid Carbon Nanotube/Agarose Fibers for Neural Tissue Engineering
Lewitus, D. Y., Landers, J., Branch, J. R., Smith, K. L., Callegari, G., Kohn, J., & Neimark, A. V. (2011) · Advanced Functional Materials · doi:10.1002/adfm.201002429 · Cited by 150
Cho, Y., Park, S., Lee, J., & Yu, K. J. (2021) · Advanced Materials · doi:10.1002/adma.202005786 · Cited by 151
Ware, T., Simon, D., Hearon, K., Liu, C., Shah, S., Reeder, J., Khodaparast, N., Kilgard, M. P., Maitland, D. J., Rennaker, R. L., et al. (2012) · Macromolecular Materials and Engineering · doi:10.1002/mame.201200241 · Cited by 138
Flexible fiber-based optoelectronics for neural interfaces
Park, S., Loke, G., Fink, Y., & Anikeeva, P. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00710a · Cited by 134
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
Robust Wireless Power Transmission to mm-Sized Free-Floating Distributed Implants
Mirbozorgi, S. A., Yeon, P., & Ghovanloo, M. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2017.2663358 · Cited by 127
Injectable 3-D Fabrication of Medical Electronics at the Target Biological Tissues
Jin, C., Zhang, J., Li, X., Yang, X., Li, J., & Liu, J. (2013) · Scientific Reports · doi:10.1038/srep03442 · Cited by 134
“and (3) represent the fabrication process of electrode mode; (4) denotes the”
BackgroundMethodLee, J. H., Kim, H., Kim, J. H., & Lee, S.-H. (2016) · Lab on a Chip · doi:10.1039/c5lc00842e · Cited by 124
Lee, B., Koripalli, M. K., Jia, Y., Acosta, J., Sendi, M. S. E., Choi, Y., & Ghovanloo, M. (2018) · Scientific Reports · doi:10.1038/s41598-018-24465-1 · Cited by 120
Biodegradable Polyanhydrides as Encapsulation Layers for Transient Electronics
Choi, Y. S., Koo, J., Lee, Y. J., Lee, G., Avila, R. O., Ying, H., Reeder, J. T., Hambitzer, L., Im, K., Jungwon, K., et al. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202000941 · Cited by 124
Graphene oxide doped conducting polymer nanocomposite film for electrode-tissue interface
Tian, H., Liu, J., Wei, D., Kang, X., Zhang, C., Du, J., Yang, B. T., Chen, X., Zhu, H., NuLi, Y., et al. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.11.058 · Cited by 135
“The problem is that smaller size, certainly lowers the damage to the tissue, would inevitably damage the performance and safety of the electrodes [10].”
BackgroundWang, W., Li, K., Ma, W., Li, Y., Liu, F., Kong, Y., Wang, L., Yi, F., Sang, Y., Li, G., et al. (2025) · Nature Materials · doi:10.1038/s41563-025-02214-w · Cited by 143
Xiang, Z., Yen, S., Sheshadri, S., Wang, J., Lee, S., Liu, Y., Liao, L., Thakor, N. V., & Lee, C. (2016) · Advanced Materials · doi:10.1002/adma.201503423 · Cited by 116
Interfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review
Yildiz, K. A., Shin, A. Y., & Kaufman, K. R. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00667-5 · Cited by 113
Kleber, C., Lienkamp, K., Rühe, J., & Asplund, M. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201801488 · Cited by 119
Neural interfaces for somatosensory feedback: bringing life to a prosthesis
Tyler, D. J. (2015) · Current Opinion in Neurology · doi:10.1097/wco.0000000000000266 · Cited by 105
Badia, J., Boretius, T., Pascual-Font, A., Udina, E., Stieglitz, T., & Navarro, X. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2153850 · Cited by 103
“is likely attributable to the surgical implantation procedure, since damage to the perineurium leads to endoneurial edema, increase in endoneurial pressure, and nerve fiber compression [23].”
BackgroundMultifunctional Fibers as Tools for Neuroscience and Neuroengineering
Canales, A., Park, S., Kilias, A., & Anikeeva, P. (2018) · Accounts of Chemical Research · doi:10.1021/acs.accounts.7b00558 · Cited by 105
The density difference between tissue and neural probes is a key factor for glial scarring
Lind, G., Linsmeier, C. E., & Schouenborg, J. (2013) · Scientific Reports · doi:10.1038/srep02942 · Cited by 102
Froeter, P. J., Huang, Y., Cangellaris, O. V., Huang, W., Dent, E. W., Gillette, M. U., Williams, J. C., & Li, X. (2014) · ACS Nano · doi:10.1021/nn504876y · Cited by 114
Ultraflexible Neural Electrodes for Long-Lasting Intracortical Recording
He, F., Lycke, R., Ganji, M., Xie, C., & Luan, L. (2020) · iScience · doi:10.1016/j.isci.2020.101387 · Cited by 105
“post-implantation conditions, and their relatively strong chronic invasiveness to the surrounding tissue (Grill et al., 2009; Polikov et al., 2005; Rousche and Normann, 1998).”
BackgroundMethodInfluentialInterfacing the Somatosensory System to Restore Touch and Proprioception: Essential Considerations
Weber, D. J., Friesen, R., & Miller, L. E. (2012) · Journal of Motor Behavior · doi:10.1080/00222895.2012.735283 · Cited by 98
“During these procedures, the awake patients described these sensations as tingling, cold, hot, painful, and often as unnatural Grill et al. (2005).”
BackgroundMaria, F. D., Lodola, F., Zucchetti, E., Benfenati, F., & Lanzani, G. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00860k · Cited by 101
Electrical Performance of Penetrating Microelectrodes Chronically Implanted in Cat Cortex
Kane, S. R., Cogan, S. F., Ehrlich, J., Plante, T. D., McCreery, D. B., & Troyk, P. R. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2248152 · Cited by 95
“Loss of communication may occur by several mechanisms, including peri-electrode gliosis [1], [7] and neuronal death or inactivity [8], [9].”
Large-scale Topographical Screen for Investigation of Physical Neural-Guidance Cues
Li, W., Tang, Q. Y., Jadhav, A., Narang, A., Qian, W. X., Shi, P., & Pang, S. W. (2015) · Scientific Reports · doi:10.1038/srep08644 · Cited by 96
Intracortical Recording Interfaces: Current Challenges to Chronic Recording Function
Gunasekera, B., Saxena, T., Bellamkonda, R., & Karumbaiah, L. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn5002864 · Cited by 93
Self-citationLu, Y., Li, Y., Pan, J., Wei, P., Liu, N., Wu, B., Cheng, J., Lu, C., & Wang, L. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.09.083 · Cited by 102
“Next, a chronic response occurred, and the glial encapsulation layer around the optrode arrays became thinner and denser, finally stabilizing [28].”
BackgroundOn prosthetic control: A regenerative agonist-antagonist myoneural interface
Srinivasan, S. S., Carty, M. J., Calvaresi, P. W., Clites, T. R., Maimon, B. E., Taylor, C. R., Zorzos, A. N., & Herr, H. (2017) · Science Robotics · doi:10.1126/scirobotics.aan2971 · Cited by 90
Heo, D. N., Song, S.-J., Kim, H., Lee, Y. J., Ko, W., Lee, S. J., Lee, D., Park, S. J., Zhang, L. G., Kang, J. Y., et al. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.05.009 · Cited by 98
Advanced Implantable Biomedical Devices Enabled by Triboelectric Nanogenerators
Wang, C., Shi, Q., & Lee, C. (2022) · Nanomaterials · doi:10.3390/nano12081366 · Cited by 100
An Inductively-Powered Wireless Neural Recording and Stimulation System for Freely-Behaving Animals
Lee, B., Jia, Y., Mirbozorgi, S. A., Connolly, M., Tong, X., Zeng, Z., Mahmoudi, B., & Ghovanloo, M. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2891303 · Cited by 88
“W IRELESS neural interfacing technology can improve the patients’ quality of life in clinical usage by eliminating the need for hardwires breaking the skin barrier for chronic monitoring and treatment [1]–[5].”
BackgroundDelbeke, J., Hoffman, L., Mols, K., Braeken, D., & Prodanov, D. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00663 · Cited by 87
“Readers are referred to the recent review of Grill et al. (2009) for update on the topic.”
BackgroundSelectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review.
Ghafoor, U., Kim, S., & Hong, K.-S. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00059 · Cited by 88
“A ramp pulse can be used to activate distal axons before closer ones (Grill and Mortimer, 1997; Grill et al., 2009), while a quasi-trapezoidal pulse have been employed for recruitment of smaller axons before larger ones (Fang and Mortimer, 1991).”
A Parylene Neural Probe Array for Multi-Region Deep Brain Recordings
Wang, X., Weltman, A., Xu, H., Slingsby-Smith, Z., Lecomte, A., Scholten, K., Song, D. B., & Meng, E. F. (2020) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2020.3000235 · Cited by 94
“In order to access and study deeper brain structures such as the hippocampus, thalamus, and basal ganglia across species with brains of varying sizes [34]–[36], there is a need for longer penetrating polymer probes that overcome these surgi-”
BackgroundFlexible and highly biocompatible nanofiber-based electrodes for neural surface interfacing
Heo, D. N., Kim, H.-J., Lee, Y. J., Heo, M., Lee, S. J., Lee, D., Do, S. H., Lee, S. H., & Kwon, I. K. (2017) · ACS Nano · doi:10.1021/acsnano.6b08390 · Cited by 86
Adewole, D. O., Struzyna, L. A., Burrell, J. C., Harris, J. P., Nemes, A. D., Petrov, D., Kraft, R. H., Chen, H.-C. I., Serruya, M. D., Wolf, J. A., et al. (2021) · Science Advances · doi:10.1126/sciadv.aay5347 · Cited by 90
The Evolution of Neuroprosthetic Interfaces
Adewole, D. O., Serruya, M. D., Harris, J. P., Burrell, J. C., Petrov, D., Chen, H.-C. I., Wolf, J. A., & Cullen, D. K. (2016) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.2016017198 · Cited by 92
“This goal underlies the rationale for three universal design objectives that applies to all NIs: (1) biocompatibility, (2) high-resolution/selectivity, and (3) long-term reliability/stability.”
A three-dimensional self-opening intraneural peripheral interface (SELINE)
Cutrone, A., Valle, J. D., Santos, D., Badia, J., Filippeschi, C., Micera, S., Navarro, X., & Bossi, S. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016016 · Cited by 82
“A further advantage of the SELINE anchoring system could be the reduction of the fibrotic encapsulation induced by electrode micromotion (Grill et al 2009), as the lateral wings anchored within the tissue may avoid displacements during limb movements.”
BackgroundSmaller, softer, lower-impedance electrodes for human neuroprosthesis: a pragmatic approach
Castagnola, E., Ansaldo, A., Maggiolini, E., Ius, T., Skrap, M., Ricci, D., & Fadiga, L. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00008 · Cited by 78
“…hydrogels (Crompton et al., 2007; Zhong and Bellamkonda, 2007; Abidian and Martin, 2009), polymers (Ludwig et al., 2006; Leung et al., 2008; Grill et al., 2009) or carbon nanotubes (Lovat et al., 2005; Mazzatenta et al., 2007), another strategy is to modify the physical dimensions, and…”
BackgroundNeuromodulation Management of Chronic Neuropathic Pain in the Central Nervous System
Yu, K., Niu, X., & He, B. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201908999 · Cited by 83
Intraspinal microstimulation for the recovery of function following spinal cord injury
Bamford, J. A., & Mushahwar, V. K. (2011) · Progress in brain research · doi:10.1016/b978-0-444-53815-4.00004-2 · Cited by 89
“…indicates that the inflammatory response endemic to centrally implanted, nonabsorbable structures such as microwires can be expected to subside over time so long as the applied electrical stimulus is within safe levels (Grill et al., 2009) and the implants are stable within the spinal cord tissue.”
BackgroundLycke, R., Kim, R., Zolotavin, P., Montes, J., Sun, Y., Kőszeghy, Á., Altun, E., Noble, B., Yin, R., He, F., et al. (2023) · Cell Reports · doi:10.1016/j.celrep.2023.112554 · Cited by 81
Physiological Challenges for Intracortical Electrodes
Groothuis, J., Ramsey, N. F., Ramakers, G. M. J., & Plasse, G. (2013) · Brain stimulation · doi:10.1016/j.brs.2013.07.001 · Cited by 86
“Applying a thin layer of laminin on implants is hypothesized to stabilize the interface between implants and the local neural environment [5].”
Miniature ultrasonically powered wireless nerve cuff stimulator
Larson, P. J., & Towe, B. C. (2011) · 2011 5th International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2011.5910538 · Cited by 75
“Wires used in implantable stimulators have a number of drawbacks including a higher degree of difficulty and invasiveness during surgery, a risk of infection, a substrate for growth of scar tissue, potential for lead breakage due to flexure or impact, and irritation or damage to tissues due to inherent differences in…”
BackgroundNext-Generation Healthcare: Enabling Technologies for Emerging Bioelectromagnetics Applications
Kiourti, A., Abbosh, A. M., Αθανασίου, Μ., Björninen, T., Eid, A., Furse, C. M., Ito, K., Lazzi, G., Manoufali, M., Pastorino, M., et al. (2022) · IEEE Open Journal of Antennas and Propagation · doi:10.1109/ojap.2022.3162110 · Cited by 87
“An increasing number of medical conditions are being treated with neurostimulators, and have resulted in encouraging, and sometimes dramatic, partial restoration of function [310].”
BackgroundRecent advances in materials and flexible electronics for peripheral nerve interfaces
Bettinger, C. J. (2018) · Bioelectronic Medicine · doi:10.1186/s42234-018-0007-6 · Cited by 77
“Microfabricated multielectrode arrays for PNI have grown in complexity leading to form factors that including Michigan arrays, Utah arrays, Utah slant arrays, transverse intrafascicular multielectrodes (TIME), longitudinal intrafascicular electrodes (LIFE), regenerative sieve electrodes, tissueengineered electrodes, a…”
BackgroundSmart Polymers for Neural Interfaces
Ware, T., Simon, D., Rennaker, R. L., & Voit, W. (2013) · Polymer Reviews · doi:10.1080/15583724.2012.751924 · Cited by 73
Using Artificial Skin Devices as Skin Replacements: Insights into Superficial Treatment
Low, Z. W. K., Li, Z., Owh, C., Chee, P. L., Ye, E., Kai, D., Yang, D., & Loh, X. J. (2019) · Small · doi:10.1002/smll.201805453 · Cited by 77
Aristovich, K. Y., Donegà, M., Fjordbakk, C. T., Tarotin, I., Chapman, C. A. R., Viscasillas, J., Stathopoulou, T., Crawford, A. H., Chew, D. J., PERKINS, J. D., et al. (2021) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2021.109079 · Cited by 80
Richter, C., & Tan, X. (2014) · Hearing Research · doi:10.1016/j.heares.2014.03.008 · Cited by 76
Kang, K., Lee, S., Kim, R., Choi, I. S., & Nam, Y. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201207129 · Cited by 72
A Review of Control Strategies in Closed-Loop Neuroprosthetic Systems
Wright, J. C., Macefield, V. G., André, V. S., & Tapson, J. C. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00312 · Cited by 78
“For a more thorough description of the available neuroprosthetic devices and interface technologies, the reader is directed to the following excellent reviews (Navarro et al., 2005; Grill et al., 2009; Micera et al., 2010; Ortiz-Catalan et al., 2012).”
Background
Metadata
- Authors
- Grill, W. M., Norman, S. E., & Bellamkonda, R. V.
- Affiliations
- Duke University (US)
- Georgia Institute of Technology (US)
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2009-08-01
- Volume
- 11
- Issue
- 1
- Pages
- 1-24
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2118756387
- Semantic Scholar
- 46b193b47ceebfd3b792cc3da8f142b50b7cffb3
- Cited by
- 488
- References
- 148
- Citations by year
- 2026: 14 · 2025: 15 · 2024: 26 · 2023: 31 · 2022: 24 · 2021: 39 · 2020: 37 · 2019: 43 · 2018: 35 · 2017: 43 · 2016: 34 · 2015: 35 · 2014: 25 · 2013: 29 · 2012: 17
- FWCI
- 1.67
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Annual Review of Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Social Sciences › Education › Undergraduate Neuroscience Education and Research
- Keywords
- neural interfaces, neural recording, neurostimulation, electrode design, electrode geometry, stimulation waveform, implant materials, surface modification, selectivity, peripheral nerves, spinal cord, optical stimulation, inflammation control
- MeSH terms
- Animals, Biophysics, Electric Stimulation, Electrodes, Implanted, Ganglia, Spinal, Humans, Inflammation, Models, Biological, Models, Neurological, Nerve Net, Neurons, Peripheral Nervous System, Optics and Photonics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.