Microfluidic Platforms for Single-Cell Analysis
The DOI matches its Crossref record; 56 of the 56 references it cites were found in a registry or an index.
Abstract
Microfluidics, the study and control of the fluidic behavior in microstructures, has emerged as an important enabling tool for single-cell chemical analysis. The complex procedures for chemical cytometry experiments can be integrated into a single microfabricated device. The capability of handling a volume of liquid as small as picoliters can be utilized to manipulate cells, perform controlled cell lysis and chemical reactions, and efficiently minimize sample dilution after lysis. The separation modalities such as chromatography and electrophoresis within microchannels are incorporated to analyze various types of intracellular components quantitatively. The microfluidic approach offers a rapid, accurate, and cost-effective tool for single-cell biology. We present an overview of the recent developments in microfluidic technology for chemical-content analysis of individual cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Phylogenetic identification and in situ detection of individual microbial cells without cultivation
Amann, R., Ludwig, W., & SCHLEIFER, K. H. (1995) · Microbiological Reviews · doi:10.1128/mmbr.59.1.143-169.1995 · Cited by 9,093
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Soft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,607
The Uncultured Microbial Majority
Rappé, M. S., & Giovannoni, S. J. (2003) · Annual Review of Microbiology · doi:10.1146/annurev.micro.57.030502.090759 · Cited by 2,017
Mechanisms of Pulsed Laser Ablation of Biological Tissues
Vogel, A., & Venugopalan, V. (2003) · Chemical Reviews · doi:10.1021/cr010379n · Cited by 1,918
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
Stochastic mRNA Synthesis in Mammalian Cells
Raj, A., Peskin, C. S., Tranchina, D., Vargas, D. Y., & Tyagi, S. (2006) · PLoS Biology · doi:10.1371/journal.pbio.0040309 · Cited by 1,737
Comprehensive human genome amplification using multiple displacement amplification
Dean, F. B., Hosono, S., Fang, L., Wu, X., Faruqi, A. F., Bray-Ward, P., Sun, Z., Zong, Q., Du, Y., Du, J., et al. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.082089499 · Cited by 1,467
Massively parallel manipulation of single cells and microparticles using optical images
Chiou, P. Y., Ohta, A. T., & Wu, M. C. (2005) · Nature · doi:10.1038/nature03831 · Cited by 1,444
Systems Biology and New Technologies Enable Predictive and Preventative Medicine
Hood, L., Heath, J. R., Phelps, M. E., & Lin, B. (2004) · Science · doi:10.1126/science.1104635 · Cited by 1,108
Transcriptome-wide noise controls lineage choice in mammalian progenitor cells
Chang, H. H., Hemberg, M., Barahona, M., Ingber, D. E., & Huang, S. (2008) · Nature · doi:10.1038/nature06965 · Cited by 1,092
Droplet microfluidic technology for single-cell high-throughput screening
Brouzes, E., Medkova, M., Savenelli, N., Marran, D., Twardowski, M., Hutchison, J. B., Rothberg, J. M., Link, D. R., Perrimon, N., & Samuels, M. L. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0903542106 · Cited by 1,069
Oh, K. W., & Ahn, C. H. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/5/r01 · Cited by 838
Microfluidic Digital PCR Enables Multigene Analysis of Individual Environmental Bacteria
Ottesen, E. A., Hong, J. W., Quake, S. R., & Leadbetter, J. R. (2006) · Science · doi:10.1126/science.1131370 · Cited by 737
Dubnau, D., & Losick, R. (2006) · Molecular Microbiology · doi:10.1111/j.1365-2958.2006.05249.x · Cited by 726
Marcy, Y., Ouverney, C., Bik, E. M., Lösekann, T., Ivanova, N., Martin, H. G., Szeto, E., Platt, D., Hugenholtz, P., Relman, D. A., et al. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0704662104 · Cited by 634
Madou, M., Zoval, J., Jia, G., Kido, H., Kim, J., & Kim, N. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095758 · Cited by 568
Single-Cell Gene Expression Profiling
Levsky, J. M., Shenoy, S. M., Pezo, R. C., & Singer, R. H. (2002) · Science · doi:10.1126/science.1072241 · Cited by 526
He, M., Edgar, J. S., Jeffries, G. D. M., Lorenz, R. M., Shelby, J. P., & Chiu, D. T. (2005) · Analytical Chemistry · doi:10.1021/ac0480850 · Cited by 518
Optical sensing systems for microfluidic devices: A review
Kuswandi, B., Nuriman, Huskens, J., & Verboom, W. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.08.046 · Cited by 464
Counting Low-Copy Number Proteins in a Single Cell
Huang, B., Wu, H., Bhaya, D., Grossman, A., Granier, S., Kobilka, B. K., & Zare, R. N. (2007) · Science · doi:10.1126/science.1133992 · Cited by 387
Self-citationMicrofluidic Devices for the High-Throughput Chemical Analysis of Cells
McClain, M. A., Culbertson, C. T., Jacobson, S. C., Allbritton, N. L., Sims, C. E., & Ramsey, J. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346510 · Cited by 383
Microfluidic Single-Cell mRNA Isolation and Analysis
Marcus, J. S., Anderson, W. F., & Quake, S. R. (2006) · Analytical Chemistry · doi:10.1021/ac0519460 · Cited by 351
Assembling the Marine Metagenome, One Cell at a Time
Woyke, T., Xie, G., Copeland, A., González, J. M., Han, C., Kiss, H., Saw, J. H., Senin, P., Yang, C., Chatterji, S., et al. (2009) · PLoS ONE · doi:10.1371/journal.pone.0005299 · Cited by 332
Microfluidics-based systems biology
Breslauer, D. N., Lee, P. J., & Lee, L. P. (2006) · Molecular BioSystems · doi:10.1039/b515632g · Cited by 303
Nanoliter Reactors Improve Multiple Displacement Amplification of Genomes from Single Cells
Marcy, Y., Ishoey, T., Lasken, R. S., Stockwell, T. B., Walenz, B. P., Halpern, A. L., Beeson, K. Y., Goldberg, S. M. D., & Quake, S. R. (2007) · PLoS Genetics · doi:10.1371/journal.pgen.0030155 · Cited by 286
Whole-genome multiple displacement amplification from single cells
Spits, C., Le Caignec, C., De Rycke, M., Van Haute, L., Van Steirteghem, A., Liebaers, I., & Sermon, K. (2006) · Nature Protocols · doi:10.1038/nprot.2006.326 · Cited by 282
Electroporation of cells in microfluidic devices: a review
Fox, M. B., Esveld, D. C., Valero, A., Luttge, R., Mastwijk, H. C., Bartels, P. V., van den Berg, A., & Boom, R. M. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0327-3 · Cited by 247
Reagentless mechanical cell lysis by nanoscale barbs in microchannels for sample preparation
Carlo, D. D., Jeong, K.-H., & Lee, L. P. (2003) · Lab on a Chip · doi:10.1039/b305162e · Cited by 246
Chemical cytometry on a picoliter-scale integrated microfluidic chip
Wu, H., Wheeler, A., & Zare, R. N. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0405299101 · Cited by 241
Self-citationA microfluidic processor for gene expression profiling of single human embryonic stem cells
Zhong, J. F., Chen, Y., Marcus, J. S., Scherer, A., Quake, S. R., Taylor, C. R., & Weiner, L. P. (2008) · Lab Chip · doi:10.1039/b712116d · Cited by 234
Chou, H.-P., Unger, M. A., & Quake, S. R. (2001) · Biomedical Microdevices · doi:10.1023/a:1012412916446 · Cited by 223
Cell lysis on a microfluidic CD (compact disc)
Kim, J.-T., Jang, S. H., Jia, G., Zoval, J. V., Silva, N. A. D., & Madou, M. J. (2004) · Lab on a Chip · doi:10.1039/b401106f · Cited by 151
Fortier, M., Bonneil, É., Goodley, P. C., & Thibault, P. (2005) · Analytical Chemistry · doi:10.1021/ac048506d · Cited by 144
Intuitive, Image-Based Cell Sorting Using Optofluidic Cell Sorting
Kovač, J., & Voldman, J. (2007) · Analytical Chemistry · doi:10.1021/ac071366y · Cited by 137
Huang, B., Wu, H., Kim, S., & Zare, R. N. (2005) · Lab on a Chip · doi:10.1039/b509251e · Cited by 135
Self-citationHellmich, W., Pelargus, C., Leffhalm, K., Ros, A., & Anselmetti, D. (2005) · Electrophoresis · doi:10.1002/elps.200500185 · Cited by 126
Investigation of laser-induced cell lysis using time-resolved imaging
Rau, K. R., Guerra, A., Vogel, A., & Venugopalan, V. (2004) · Applied Physics Letters · doi:10.1063/1.1705728 · Cited by 113
Purification of Nucleic Acids from Whole Blood Using Isotachophoresis
Persat, A., Marshall, L. A., & Santiago, J. G. (2009) · Analytical Chemistry · doi:10.1021/ac901965v · Cited by 113
Examination of laser microbeam cell lysis in a PDMS microfluidic channel using time-resolved imaging
Quinto-Su, P. A., Lai, H., Yoon, H. H., Sims, C. E., Allbritton, N. L., & Venugopalan, V. (2008) · Lab on a Chip · doi:10.1039/b715708h · Cited by 113
Chemical Cytometry: Fluorescence-Based Single-Cell Analysis
Cohen, D., Dickerson, J. A., Whitmore, C. D., Turner, E. H., Palcic, M. M., Hindsgaul, O., & Dovichi, N. J. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.113104 · Cited by 109
Optical and electrochemical detection techniques for cell-based microfluidic systems
Yi, C., Zhang, Q., Li, C., Yang, J., Zhao, J., & Yang, M. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-0252-x · Cited by 106
Chemical Analysis of Single Cells
Borland, L. M., Kottegoda, S., Phillips, K. S., & Allbritton, N. L. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.113100 · Cited by 102
Integrating whole transcriptome assays on a lab-on-a-chip for single cell gene profiling
Bontoux, N., Dauphinot, L., Vitalis, T., Studer, V., Chen, Y., Rossier, J., & Potier, M. (2008) · Lab on a Chip · doi:10.1039/b716543a · Cited by 100
Fully integrated microfluidic separations systems for biochemical analysis
Roman, G. T., & Kennedy, R. T. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.06.010 · Cited by 97
Recent advances in capillary separations for proteomics
Cooper, J. W., Wang, Y., & Lee, C. S. (2004) · ELECTROPHORESIS · doi:10.1002/elps.200406154 · Cited by 92
Electrochemical detection in a microfluidic device of oxidative stress generated by macrophage cells
Amatore, C. A., Arbault, S., Chen, Y., Crozatier, C., & Tapsoba, I. (2006) · Lab on a Chip · doi:10.1039/b611569a · Cited by 88
Sasuga, Y., Iwasawa, T., Terada, K., Ooe, Y., Sorimachi, H., Ohara, O., & Harada, Y. (2008) · Analytical Chemistry · doi:10.1021/ac8016423 · Cited by 63
Hutchison, C. A., & Venter, J. C. (2006) · Nature Biotechnology · doi:10.1038/nbt0606-657 · Cited by 62
Polyadenylation of mRNA in bacteria
Sarkar, N. (1996) · Microbiology · doi:10.1099/13500872-142-11-3125 · Cited by 60
Liu, C.-J., Lien, K.-Y., Weng, C., Shin, J.-W., Chang, T., & Lee, G. (2008) · Biomedical Microdevices · doi:10.1007/s10544-008-9240-1 · Cited by 55
Genome-wide transcriptome analysis of 150 cell samples
Irimia, D., Mindrinos, M. N., Russom, A., Xiao, W., Wilhelmy, J., Wang, S., Heath, J. D., Kurn, N., Tompkins, R. G., Davis, R. W., et al. (2008) · Integrative Biology · doi:10.1039/b814329c · Cited by 19
Kralj, J. G., Player, A. N., Sedrick, H., Munson, M. S., Petersen, D., Forry, S. P., Meltzer, P. S., Kawasaki, E. S., & Locascio, L. E. (2008) · Lab on a Chip · doi:10.1039/b811714d · Cited by 18
Chemical cytometry: the chemical analysis of single cells
Turner, E. H., Cohen, D., Pugsley, H. R., González‐Gómez, D., Whitmore, C. D., Zhu, C., & Dovic̀hi, N. J. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1665-5 · Cited by 16
Cited by
Microfluidic Chips for Point‐of‐Care Immunodiagnostics
Gervais, L., de Rooij, N., & Delamarche, E. (2011) · Advanced Materials · doi:10.1002/adma.201100464 · Cited by 491
High-throughput microfluidic single-cell RT-qPCR
White, A. K., VanInsberghe, M., Petriv, O. I., Hamidi, M., Sikorski, D., Marra, M. A., Piret, J., Aparicio, S., & Hansen, C. L. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1019446108 · Cited by 440
Cell-Based Biosensors and Their Application in Biomedicine
Liu, Q., Wu, C., Cai, H., Hu, N., Zhou, J., & Wang, P. (2014) · Chemical Reviews · doi:10.1021/cr2003129 · Cited by 348
Biomedical microfluidic devices by using low-cost fabrication techniques: A review
Faustino, V., Catarino, S. O., Lima, R., & Minas, G. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.11.031 · Cited by 338
Industrial lab-on-a-chip: Design, applications and scale-up for drug discovery and delivery
Vladisavljević, G. T., Khalid, N., Neves, M. A., Kuroiwa, T., Nakajima, M., Uemura, K., Ichikawa, S., & Kobayashi, I. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.017 · Cited by 313
Metadata
- Authors
- Zare, R. N., & Kim, S.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2010-07
- Volume
- 12
- Issue
- 1
- Pages
- 187-201
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2161203530
- Cited by
- 318
- References
- 56
- FWCI
- 2.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.