The Role of Body-on-a-Chip Devices in Drug and Toxicity Studies

Esch, M.B., King, T.L., Shuler, M.L.·2011·Annual Review of Biomedical Engineering

Abstract

High-quality, in vitro screening tools are essential in identifying promising compounds during drug development. Tests with currently used cell-based assays provide an indication of a compound's potential therapeutic benefits to the target tissue, but not to the whole body. Data obtained with animal models often cannot be extrapolated to humans. Multicompartment microfluidic-based devices, particularly those that are physical representations of physiologically based pharmacokinetic (PBPK) models, may contribute to improving the drug development process. These scaled-down devices, termed micro cell culture analogs (μCCAs) or body-on-a-chip devices, can simulate multitissue interactions under near-physiological fluid flow conditions and with realistic tissue-to-tissue size ratios. Because the device can be used with both animal and human cells, it can facilitate cross-species extrapolation. Used in conjunction with PBPK models, the devices permit an estimation of effective concentrations that can be used for studies with animal models or predict the human response. The devices also provide a means for relatively high-throughput screening of drug combinations and, when utilized with a patient's tissue sample, an opportunity for individualized medicine. Here we review efforts made toward the development of microfabricated cell culture systems and give examples that demonstrate their potential use in drug development, such as identifying synergistic drug interactions as well as simulating multiorgan metabolic interactions. In addition to their use in drug development, the devices also can be used to estimate the toxicity of chemicals as occupational hazards and environmental contaminants.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1146/annurev-bioeng-071910-124629

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 328

Metadata

Authors
Esch, M. B., King, T. L., & Shuler, M. L.
Venue
Annual Review of Biomedical Engineering
Published
2011-08-15
Volume
13
Issue
1
Pages
55-72
ISSN
  • 1523-9829 (ISSN-L)
  • 1545-4274
OpenAlex
W2168253538
Cited by
328
References
8
FWCI
1.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Role of Body-on-a-Chip Devices in Drug and Toxicity Studies. https://app.cochat.ai/papers/10.1146/annurev-bioeng-071910-124629
The paper
Esch, M. B., King, T. L., & Shuler, M. L. (2011). The Role of Body-on-a-Chip Devices in Drug and Toxicity Studies. Annual Review of Biomedical Engineering. https://doi.org/10.1146/annurev-bioeng-071910-124629

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.