The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
The Role of Body-on-a-Chip Devices in Drug and Toxicity Studies
Abstract
High-quality, in vitro screening tools are essential in identifying promising compounds during drug development. Tests with currently used cell-based assays provide an indication of a compound's potential therapeutic benefits to the target tissue, but not to the whole body. Data obtained with animal models often cannot be extrapolated to humans. Multicompartment microfluidic-based devices, particularly those that are physical representations of physiologically based pharmacokinetic (PBPK) models, may contribute to improving the drug development process. These scaled-down devices, termed micro cell culture analogs (μCCAs) or body-on-a-chip devices, can simulate multitissue interactions under near-physiological fluid flow conditions and with realistic tissue-to-tissue size ratios. Because the device can be used with both animal and human cells, it can facilitate cross-species extrapolation. Used in conjunction with PBPK models, the devices permit an estimation of effective concentrations that can be used for studies with animal models or predict the human response. The devices also provide a means for relatively high-throughput screening of drug combinations and, when utilized with a patient's tissue sample, an opportunity for individualized medicine. Here we review efforts made toward the development of microfabricated cell culture systems and give examples that demonstrate their potential use in drug development, such as identifying synergistic drug interactions as well as simulating multiorgan metabolic interactions. In addition to their use in drug development, the devices also can be used to estimate the toxicity of chemicals as occupational hazards and environmental contaminants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Can the pharmaceutical industry reduce attrition rates?
Kola, I., & Landis, J. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1470 · Cited by 4,167
Role of Quinones in Toxicology
Bolton, J. L., Trush, M. A., Penning, T. M., Dryhurst, G., & Monks, T. J. (2000) · Chemical Research in Toxicology · doi:10.1021/tx9902082 · Cited by 1,703
Cellular mechanotransduction: putting all the pieces together again
Ingber, D. E. (2006) · The FASEB Journal · doi:10.1096/fj.05-5424rev · Cited by 1,627
Decrease in anogenital distance among male infants with prenatal phthalate exposure
Swan, S. H., Main, K. M., Liu, F., Stewart, S. L., Kruse, R. L., Calafat, A. M., Mao, C. S., Redmon, J. B., Ternand, C. L., Sullivan, S., et al. (2005) · Environmental Health Perspectives · doi:10.1289/ehp.8100 · Cited by 1,586
Bhatia, S. N., Balis, U. J., Yarmush, M. L., & Toner, M. (1999) · The FASEB Journal · doi:10.1096/fasebj.13.14.1883 · Cited by 890
Wilkening, S., Stahl, F., & Bader, A. (2003) · Drug Metabolism and Disposition · doi:10.1124/dmd.31.8.1035 · Cited by 794
Zhang, C., Zhao, Z., Abdul Rahim, N. A., van Noort, D., & Yu, H. (2009) · Lab on a Chip · doi:10.1039/b915147h · Cited by 340
Cited by
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
25th Anniversary Article: Rational Design and Applications of Hydrogels in Regenerative Medicine
Annabi, N., Tamayol, A., Uquillas, J. A., Akbari, M., Bertassoni, L. E., Cha, C., Camci‐Unal, G., Dokmeci, M. R., Peppas, N. A., & Khademhosseini, A. (2014) · Advanced Materials · doi:10.1002/adma.201303233 · Cited by 1,409
Organs-on-chips at the frontiers of drug discovery
Esch, E. W., Bahinski, A., & Huh, D. (2015) · Nature Reviews Drug Discovery · doi:10.1038/nrd4539 · Cited by 1,185
Advances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 958
Maschmeyer, I., Lorenz, A. K., Schimek, K., Hasenberg, T., Ramme, A. P., Hübner, J., Lindner, M., Drewell, C., Bauer, S., Thomas, A., et al. (2015) · Lab on a Chip · doi:10.1039/c5lc00392j · Cited by 861
Metadata
- Authors
- Esch, M. B., King, T. L., & Shuler, M. L.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2011-08-15
- Volume
- 13
- Issue
- 1
- Pages
- 55-72
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2168253538
- Cited by
- 328
- References
- 8
- FWCI
- 1.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Role of Body-on-a-Chip Devices in Drug and Toxicity Studies. https://app.cochat.ai/papers/10.1146/annurev-bioeng-071910-124629
- The paper
- Esch, M. B., King, T. L., & Shuler, M. L. (2011). The Role of Body-on-a-Chip Devices in Drug and Toxicity Studies. Annual Review of Biomedical Engineering. https://doi.org/10.1146/annurev-bioeng-071910-124629
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.