Current Status of Developments and Applications of Micro-CT
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Use of microscopic computed-tomography (micro-CT) scanning continues to grow in biomedical research. Laboratory-based micro-CT scanners, laboratory-based nano-CT scanners, and integrated micro-CT/SPECT and micro-CT/PET scanners are now manufactured for “turn-key” operation by a number of commercial vendors. In recent years a number of technical developments in X-ray sources and X-ray imaging arrays have broadened the utility of micro-CT. Of particular interest are photon-counting and energy-resolving detector arrays. These are being explored to maximize micro-CT image grayscale dynamic range and to further increase image contrast by utilizing the unique spectral attenuation characteristics of individual chemical elements. X-ray phase-shift images may increase contrast resolution and reduce radiation exposure. Although radiation exposure is becoming a concern with the drive for increased spatial and temporal resolution, especially for longitudinal studies, gated scans and limited scan-data-set reconstruction algorithms show great potential for keeping radiation exposure to a minimum.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources
Pfeiffer, F., Weitkamp, T., Bunk, O., & David, C. (2006) · Nature Physics · doi:10.1038/nphys265 · Cited by 1,855
High resolution X-ray computed tomography: an emerging tool for small animal cancer research
Paulus, M. J., Gleason, S. S., Kennel, S. J., Hunsicker, P. R., & Johnson, D. K. (2000) · Neoplasia · doi:10.1038/sj.neo.7900069 · Cited by 490
Cited by
Multifunctional in vivo vascular imaging using near-infrared II fluorescence
Hong, G., Lee, J. C., Robinson, J. T., Raaz, U., Xie, L., Huang, N. F., Cooke, J. P., & Dai, H. (2012) · Nature Medicine · doi:10.1038/nm.2995 · Cited by 995
Wu, Y. C., Zhu, B., Li, G., Zhang, X. H., Yu, M. H., Dong, K. G., Zhang, T. K., Yang, Y., Bi, B., Yang, J., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-33844-7 · Cited by 268
Cengiz, I. F., Oliveira, J. M., & Reis, R. L. (2018) · Biomaterials Research · doi:10.1186/s40824-018-0136-8 · Cited by 206
Rapid Prototyping for Biomedical Engineering: Current Capabilities and Challenges
Lantada, A. D., & Morgado, P. L. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150112 · Cited by 171
Metadata
- Authors
- Ritman, E. L.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2011-08-15
- Volume
- 13
- Issue
- 1
- Pages
- 531-552
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2149830042
- Cited by
- 243
- References
- 2
- FWCI
- 1.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Current Status of Developments and Applications of Micro-CT. https://app.cochat.ai/papers/10.1146/annurev-bioeng-071910-124717
- The paper
- Ritman, E. L. (2011). Current Status of Developments and Applications of Micro-CT. Annual Review of Biomedical Engineering. https://doi.org/10.1146/annurev-bioeng-071910-124717
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.