Inertial Focusing in Microfluidics
Open accessThe DOI matches its Crossref record; 64 of the 64 references it cites were found in a registry or an index.
Abstract
When Segré and Silberberg in 1961 witnessed particles in a laminar pipe flow congregating at an annulus in the pipe, scientists were perplexed and spent decades learning why such behavior occurred, finally understanding that it was caused by previously unknown forces on particles in an inertial flow. The advent of microfluidics opened a new realm of possibilities for inertial focusing in the processing of biological fluids and cellular suspensions and created a field that is now rapidly expanding. Over the past five years, inertial focusing has enabled high-throughput, simple, and precise manipulation of bodily fluids for a myriad of applications in point-of-care and clinical diagnostics. This review describes the theoretical developments that have made the field of inertial focusing what it is today and presents the key applications that will make inertial focusing a mainstream technology in the future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687 · cited 1×
“Being able to process real world–sized samples efficiently has been a major challenge since the beginning of the field of microfluidics (20).”
BackgroundThe lift on a small sphere in a slow shear flow
Saffman, P. G. (1965) · Journal of Fluid Mechanics · doi:10.1017/s0022112065000824 · Cited by 3,426
Continuous inertial focusing, ordering, and separation of particles in microchannels
Di Carlo, D., Irimia, D., Tompkins, R. G., & Toner, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0704958104 · Cited by 1,708
Self-citationHigh gradient magnetic cell separation with MACS
Miltenyi, S., Müller, W., Weichel, W., & Radbruch, A. (1990) · Cytometry · doi:10.1002/cyto.990110203 · Cited by 1,681
Continuous Particle Separation Through Deterministic Lateral Displacement
Huang, L. R., Cox, E. C., Austin, R. H., & Sturm, J. C. (2004) · Science · doi:10.1126/science.1094567 · Cited by 1,634
Di Carlo, D. (2009) · Lab on a Chip · doi:10.1039/b912547g · Cited by 1,627
Berger, S. A., Talbot, L., & Yao, L. S. (1983) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.15.010183.002333 · Cited by 1,363
Radial Particle Displacements in Poiseuille Flow of Suspensions
SEGRÉ, G., & SILBERBERG, A. (1961) · Nature · doi:10.1038/189209a0 · Cited by 1,206
Ozkumur, E., Shah, A. M., Ciciliano, J. C., Emmink, B. L., Miyamoto, D. T., Brachtel, E., Yu, M., Chen, P.-I., Morgan, B., Trautwein, J., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3005616 · Cited by 1,086
Self-citationThe transverse force on a spinning sphere moving in a viscous fluid
Rubinow, S. I., & Keller, J. B. (1961) · Journal of Fluid Mechanics · doi:10.1017/s0022112061000640 · Cited by 1,074
Cited by
Collins, D. J., Neild, A., deMello, A., Liu, A.-Q., & Ai, Y. (2015) · Lab on a Chip · doi:10.1039/c5lc00614g · Cited by 528
Ahn, J. C., Teng, P., Chen, P., Posadas, E., Tseng, H., Lu, S. C., & Yang, J. D. (2021) · Hepatology · doi:10.1002/hep.31165 · Cited by 338
Particle manipulations in non-Newtonian microfluidics: A review
Lu, X., Liu, C., Hu, G., & Xuan, X. (2017) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2017.04.019 · Cited by 289
Nasiri, R., Shamloo, A., Ahadian, S., Amirifar, L., Akbari, J., Goudie, M. J., Lee, K., Ashammakhi, N., Dokmeci, M. R., Di Carlo, D., et al. (2020) · Small · doi:10.1002/smll.202000171 · Cited by 244
Viscoelastic microfluidics: progress and challenges
Zhou, J., & Papautsky, I. (2020) · Microsystems & Nanoengineering · doi:10.1038/s41378-020-00218-x · Cited by 230
Acoustofluidic centrifuge for nanoparticle enrichment and separation
Gu, Y., Chen, C., Mao, Z., Bachman, H., Becker, R., Rufo, J., Wang, Z., Zhang, P., Mai, J., Yang, S., et al. (2021) · Science Advances · doi:10.1126/sciadv.abc0467 · Cited by 227
Channel innovations for inertial microfluidics
Tang, W., Zhu, S., Jiang, D., Zhu, L., Yang, J., & Xiang, N. (2020) · Lab on a Chip · doi:10.1039/d0lc00714e · Cited by 190
Preparation and characterization of extracellular vesicles
Tiwari, S., Kumar, V., Randhawa, S., & Verma, S. K. (2021) · American Journal of Reproductive Immunology · doi:10.1111/aji.13367 · Cited by 182
Stoecklein, D., & Di Carlo, D. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05042 · Cited by 179
Che, J., Yu, V., Dhar, M., Renier, C., Matsumoto, M., Heirich, K., Garon, E. B., Goldman, J., Rao, J., Sledge, G. W., et al. (2016) · Oncotarget · doi:10.18632/oncotarget.7220 · Cited by 177
“Recent advances in inertial microfluidics have offered a more rapid platform through which cells may be sorted by size, as fluidic forces generated from high flow rates scale strongly with cell size [24, 25].”
BackgroundRecent Advances and Future Perspectives on Microfluidic Liquid Handling
Nguyen, N.-T., Hejazian, M., Ooi, C., & Kashaninejad, N. (2017) · Micromachines · doi:10.3390/mi8060186 · Cited by 175
Monolithic Chip for High-throughput Blood Cell Depletion to Sort Rare Circulating Tumor Cells
Fachin, F., Spuhler, P., Martel-Foley, J. M., Edd, J. F., Barber, T. A., Walsh, J., Karabacak, M., Pai, V., Yu, M., Smith, K., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-11119-x · Cited by 171
Self-citationIntegration of isothermal amplification methods in microfluidic devices: Recent advances
Giuffrida, M. C., & Spoto, G. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.11.045 · Cited by 169
“The specific behavior of fluids flowing in microchannels constitutes the basis of many microfluidics-based technologies (Martel and Toner, 2014; Grasso et al., 2009).”
BackgroundMicrofluidic Sample Preparation for Single Cell Analysis
Hosic, S., Murthy, S. K., & Koppes, A. N. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04077 · Cited by 166
Label-Free Isolation of Exosomes Using Microfluidic Technologies
Hassanpour Tamrin, S., Sanati Nezhad, A., & Sen, A. (2021) · ACS Nano · doi:10.1021/acsnano.1c03469 · Cited by 162
Label-free microfluidic cell sorting and detection for rapid blood analysis
Lu, N., Tay, H. M., Petchakup, C., He, L., Gong, L., Maw, K. K., Leong, S. Y., Lok, W. W., Ong, H. B., Guo, R., et al. (2023) · Lab on a Chip · doi:10.1039/d2lc00904h · Cited by 158
Metadata
- Authors
- Martel, J. M., & Toner, M.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2014-07-11
- Volume
- 16
- Issue
- 1
- Pages
- 371-396
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2154833576
- Cited by
- 571
- References
- 64
- FWCI
- 3.47
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.