The DOI matches its Crossref record; 101 of the 101 references it cites were found in a registry or an index.
Chemical Principles in Tissue Clearing and Staining Protocols for Whole-Body Cell Profiling
Open accessAbstract
Mammalian bodies have more than a billion cells per cubic centimeter, which makes whole-body cell (WBC) profiling of an organism one of the ultimate challenges in biology and medicine. Recent advances in tissue-clearing technology have enabled rapid and comprehensive cellular analyses in whole organs and in the whole body by a combination of state-of-the-art technologies of optical imaging and image informatics. In this review, we focus mainly on the chemical principles in currently available techniques for tissue clearing and staining to facilitate our understanding of their underlying mechanisms. Tissue clearing is usually conducted by the following steps: (a) fixation, (b) permeabilization, (c) decolorizing, and (d) refractive index (RI) matching. To phenotype individual cells after tissue clearing, it is important to visualize genetically encoded fluorescent reporters and/or to stain tissues with fluorescent dyes, fluorescent labeled antibodies, or nucleic acid probes. Although some technical challenges remain, the chemical principles in tissue clearing and staining for WBC profiling will enable various applications, such as identifying cellular circuits across multiple organs and measuring their dynamics in stochastic and proliferative cellular processes, for example, autoimmune and malignant neoplastic diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Green fluorescent protein as a marker for gene expression
Chalfie, M., Tu, Y., Euskirchen, G., Ward, W. W., & Prasher, D. C. (1994) · Science · doi:10.1126/science.8303295 · Cited by 6,802
Tsien, R. Y. (1998) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.67.1.509 · Cited by 6,143
Guidelines for assessment of bone microstructure in rodents using micro–computed tomography
Bouxsein, M. L., Boyd, S. K., Christiansen, B. A., Guldberg, R. E., Jepsen, K. J., & Müller, R. (2010) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.141 · Cited by 4,433
A clearer vision for in vivo imaging
Weissleder, R. (2001) · Nature Biotechnology · doi:10.1038/86684 · Cited by 3,839
A mesoscale connectome of the mouse brain
Oh, S. W., Harris, J. A., Ng, L., Winslow, B., Cain, N., Mihalas, S., Wang, Q., Lau, C., Kuan, L., Henry, A. M., et al. (2014) · Nature · doi:10.1038/nature13186 · Cited by 2,612
Shimomura, O., Johnson, F. H., & Saiga, Y. (1962) · Journal of Cellular and Comparative Physiology · doi:10.1002/jcp.1030590302 · Cited by 2,384
Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields
Ogawa, S., Lee, T., Nayak, A. S., & Glynn, P. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140108 · Cited by 2,266
Crystal Structure of the Aequorea victoria Green Fluorescent Protein
Ormö, M., Cubitt, A. B., Kallio, K., Gross, L. A., Tsien, R. Y., & Remington, S. J. (1996) · Science · doi:10.1126/science.273.5280.1392 · Cited by 2,242
Structural and molecular interrogation of intact biological systems
Chung, K., Wallace, J., Kim, S.-Y., Kalyanasundaram, S., Andalman, A. S., Davidson, T. J., Mirzabekov, J. J., Zalocusky, K. A., Mattis, J., Denisin, A. K., et al. (2013) · Nature · doi:10.1038/nature12107 · Cited by 2,008
Going deeper than microscopy: the optical imaging frontier in biology
Ntziachristos, V. (2010) · Nature Methods · doi:10.1038/nmeth.1483 · Cited by 1,896
Cited by
Protection of tissue physicochemical properties using polyfunctional crosslinkers
Park, Y.-G., Sohn, C. H., Chen, R., McCue, M., Yun, D. H., Drummond, G. T., Ku, T., Evans, N. B., Oak, H. C., Trieu, W., et al. (2019) · Nature Biotechnology · doi:10.1038/nbt.4281 · Cited by 421
Tissue clearing of both hard and soft tissue organs with the PEGASOS method
Jing, D., Zhang, S., Luo, W., Gao, X., Men, Y., Ma, C., Liu, X., Yi, Y., Bugde, A., Zhou, B. O., et al. (2018) · Cell Research · doi:10.1038/s41422-018-0049-z · Cited by 394
Chemical Landscape for Tissue Clearing Based on Hydrophilic Reagents
Tainaka, K., Murakami, T. C., Susaki, E. A., Shimizu, C., Saito, R., Takahashi, K., Hayashi-Takagi, A., Sekiya, H., Arima, Y., Nojima, S., et al. (2018) · Cell Reports · doi:10.1016/j.celrep.2018.07.056 · Cited by 337
Self-citationMurakami, T. C., Mano, T., Saikawa, S., Horiguchi, S. A., Shigeta, D., Baba, K., Sekiya, H., Shimizu, Y., Tanaka, K. F., Kiyonari, H., et al. (2018) · Nature Neuroscience · doi:10.1038/s41593-018-0109-1 · Cited by 292
Self-citationFDISCO: Advanced solvent-based clearing method for imaging whole organs
Qi, Y., Yu, T., Xu, J., Wan, P., Ma, Y., Zhu, J., Li, Y., Gong, H., Luo, Q., & Zhu, D. (2019) · Science Advances · doi:10.1126/sciadv.aau8355 · Cited by 257
Metadata
- Authors
- Tainaka, K., Kuno, A., Kubota, S. I., Murakami, T., & Ueda, H. R.
- Venue
- Annual Review of Cell and Developmental Biology
- Publisher
- Annual Reviews
- Published
- 2016-10-06
- Volume
- 32
- Issue
- 1
- Pages
- 713-741
- ISSN
- 1081-0706 (ISSN-L)
- 1530-8995
- OpenAlex
- W2301492266
- Cited by
- 277
- References
- 101
- FWCI
- 2.98
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Chemical Principles in Tissue Clearing and Staining Protocols for Whole-Body Cell Profiling. https://app.cochat.ai/papers/10.1146/annurev-cellbio-111315-125001
- The paper
- Tainaka, K., Kuno, A., Kubota, S. I., Murakami, T., & Ueda, H. R. (2016). Chemical Principles in Tissue Clearing and Staining Protocols for Whole-Body Cell Profiling. Annual Review of Cell and Developmental Biology. https://doi.org/10.1146/annurev-cellbio-111315-125001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.