Motion and Deformation of Elastic Capsules and Vesicles in Flow
The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
This article reviews the mechanical behavior of a capsule under the influence of viscous deforming forces due to a flowing fluid. It focuses on artificial capsules and vesicles with an internal liquid core enclosed by a very thin membrane with different constitutive laws. The recent modeling strategies are outlined together with their respective advantages and limitations. I then consider the motion and deformation of a single, initially spherical capsule freely suspended in a simple shear or plane hyperbolic flow and discuss the effect of the membrane constitutive law, initial prestress, membrane buckling, and bulk or membrane viscosity. Finally, I consider the flow of spherical capsules in small pores and show how numerical models can be used to evaluate the mechanical properties of the membrane.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elastic Properties of Lipid Bilayers: Theory and Possible Experiments
Helfrich, W. (1973) · Zeitschrift für Naturforschung C · doi:10.1515/znc-1973-11-1209 · Cited by 6,141
Peskin, C. S. (2002) · Acta Numerica · doi:10.1017/s0962492902000077 · Cited by 4,603
Configurations of fluid membranes and vesicles
Seifert, U. (1997) · Advances in Physics · doi:10.1080/00018739700101488 · Cited by 1,650
Mechanics and Thermodynamics of Biomembranes
Evans, E. A., Skalak, R., & Weinbaum, S. (1980) · Journal of Biomechanical Engineering · doi:10.1115/1.3138234 · Cited by 954
Strain Energy Function of Red Blood Cell Membranes
Skalak, R., Tozeren, A., Zarda, R. P., & Chien, S. (1973) · Biophysical Journal · doi:10.1016/s0006-3495(73)85983-1 · Cited by 832 · cited 1×
“Starting from the perspective of 2D elasticity and assuming in-plane isotropy, Skalak et al. (1973) proposed a law (referred to as the Sk law here) with independent surface shear and area dilatation moduli:”
BackgroundGreen, A. E., & Adkins, J. E. (1970) · Medical Entomology and Zoology · Cited by 749
Preparation of giant vesicles by external AC electric fields. Kinetics and applications
Angelova, M. I., Soléau, S., Méléard, P., Faucon, F., & Bothorel, P. (2007) · Progress in Colloid & Polymer Science · doi:10.1007/bfb0116295 · Cited by 739
Encapsulation Technologies for Active Food Ingredients and Food Processing
(2010) · Springer eBooks · doi:10.1007/978-1-4419-1008-0 · Cited by 631
Kraus, M., Wintz, W., Seifert, U., & Lipowsky, R. (1996) · Physical Review Letters · doi:10.1103/physrevlett.77.3685 · Cited by 441
Large deformation of red blood cell ghosts in a simple shear flow
Eggleton, C. D., & Popel, A. S. (1998) · Physics of Fluids · doi:10.1063/1.869703 · Cited by 362
Swinging of Red Blood Cells under Shear Flow
Abkarian, M., Faivre, M., & Viallat, A. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.188302 · Cited by 341
Full dynamics of a red blood cell in shear flow
Dupire, J., Socol, M., & Viallat, A. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1210236109 · Cited by 306
Vacillating Breathing and Tumbling of Vesicles under Shear Flow
Misbah, C. (2006) · Physical Review Letters · doi:10.1103/physrevlett.96.028104 · Cited by 278
Mechanical properties of micro- and nanocapsules: Single-capsule measurements
Fery, A., & Weinkamer, R. (2007) · Polymer · doi:10.1016/j.polymer.2007.07.050 · Cited by 267
Effect of membrane bending stiffness on the deformation of capsules in simple shear flow
POZRIKIDIS, C. (2001) · Journal of Fluid Mechanics · doi:10.1017/s0022112001004657 · Cited by 266
Transition to Tumbling and Two Regimes of Tumbling Motion of a Vesicle in Shear Flow
Kantsler, V., & Steinberg, V. (2006) · Physical Review Letters · doi:10.1103/physrevlett.96.036001 · Cited by 217
Cell Encapsulation Technology and Therapeutics
(1999) · Birkhäuser Boston eBooks · doi:10.1007/978-1-4612-1586-8 · Cited by 212
Seifert, U. (1999) · The European Physical Journal B · doi:10.1007/s100510050706 · Cited by 180
MacMECCAN, R. M., CLAUSEN, J. R., NEITZEL, G. P., & AIDUN, C. K. (2009) · Journal of Fluid Mechanics · doi:10.1017/s0022112008004011 · Cited by 166
Coupling of finite element and boundary integral methods for a capsule in a Stokes flow
Walter, J., Salsac, A. ‐., Barthès‐Biesel, D., & Le Tallec, P. (2010) · International Journal for Numerical Methods in Engineering · doi:10.1002/nme.2859 · Cited by 163 · cited 4×
“Their wavelength is determined by the node spacing (Walter et al. 2010).”
BackgroundMethodInfluentialSelf-citationTwo-Dimensional Simulation of Red Blood Cell Deformation and Lateral Migration in Microvessels
Secomb, T. W., Styp-Rekowska, B., & Pries, A. R. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-007-9275-0 · Cited by 160
Numerical Simulation of Cell Motion in Tube Flow
Pozrikidis, C. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-8975-6 · Cited by 142
Biomedical Applications of Microencapsulation
(2019) · CRC Press eBooks · doi:10.1201/9780429260469 · Cited by 139
Dynamics of viscous vesicles in shear flow
Mader, M.-A., Vitkova, V., Abkarian, M., Viallat, A., & Podgorski, T. (2006) · The European Physical Journal E · doi:10.1140/epje/i2005-10058-x · Cited by 137
An implicit immersed boundary method for three-dimensional fluid–membrane interactions
Le, D. V., White, J., Peraire, J., Lim, K. M., & Khoo, B. C. (2009) · Journal of Computational Physics · doi:10.1016/j.jcp.2009.08.018 · Cited by 112
Liposome-encapsulated actin–hemoglobin (LEAcHb) artificial blood substitutes
Li, S., Nickels, J. D., & Palmer, A. F. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.09.015 · Cited by 111 · cited 1×
“Experiments have shown that artificial blood cells could be damaged in the circulation and that this damage is directly related to the shape and deformability of the particles (Li et al. 2005).”
BackgroundMicroconfined flow behavior of red blood cells in vitro
Guido, S., & Tomaiuolo, G. (2009) · Comptes Rendus Physique · doi:10.1016/j.crhy.2009.10.002 · Cited by 110
Li, X., & Sarkar, K. (2008) · Journal of Computational Physics · doi:10.1016/j.jcp.2008.01.034 · Cited by 105
Dynamics of nonspherical capsules in shear flow
Bagchi, P., & Kalluri, R. M. (2009) · Physical Review E · doi:10.1103/physreve.80.016307 · Cited by 104
Tank-treading, swinging, and tumbling of liquid-filled elastic capsules in shear flow
Sui, Y., Low, H. T., Chew, Y. T., & Roy, P. (2008) · Physical Review E · doi:10.1103/physreve.77.016310 · Cited by 103
Fischer, T., & Schmid-Schönbein, H. (1978) · Springer eBooks · doi:10.1007/978-3-642-67059-6_26 · Cited by 88
Experimental investigation of a bioartificial capsule flowing in a narrow tube
Risso, F., Collé-Paillot, F., & Zagzoule, M. (2006) · Journal of Fluid Mechanics · doi:10.1017/s0022112005007652 · Cited by 88
Huang, W., Chang, C. B., & Sung, H. J. (2012) · Journal of Computational Physics · doi:10.1016/j.jcp.2012.01.006 · Cited by 85
Ellipsoidal capsules in simple shear flow: prolate versus oblate initial shapes
Walter, J., Salsac, A., & Barthès‐Biesel, D. (2011) · Journal of Fluid Mechanics · doi:10.1017/s0022112011000486 · Cited by 85
Self-citationKumar, A., Rivera, R. G. H., & Graham, M. D. (2013) · Journal of Fluid Mechanics · doi:10.1017/jfm.2013.592 · Cited by 81
Orbital drift of capsules and red blood cells in shear flow
Cordasco, D., & Bagchi, P. (2013) · Physics of Fluids · doi:10.1063/1.4820472 · Cited by 65
Mechanical characterization of cross-linked serum albumin microcapsules
de Loubens, C., Deschamps, J., Georgelin, M., Charrier, A. M., Edwards‐Lévy, F., & Léonetti, M. (2014) · Soft Matter · doi:10.1039/c4sm00349g · Cited by 62
Transient dynamics of an elastic capsule in a microfluidic constriction
Park, S.-Y., & Dimitrakopoulos, P. (2013) · Soft Matter · doi:10.1039/c3sm51516h · Cited by 55 · cited 1×
“This is one reason why it is difficult to perform long time computations for capsules with bending rigidity (Pozrikidis 2001). For artificial capsules with a thin homogeneous wall, the bending resistance is related to the thickness (Equation 25). It is appropriate to model the membrane wall as a 3D homogeneous materia…”
BackgroundMotion of an elastic capsule in a square microfluidic channel
Kuriakose, S., & Dimitrakopoulos, P. (2011) · Physical Review E · doi:10.1103/physreve.84.011906 · Cited by 54
Rheology of a dilute suspension of liquid-filled elastic capsules
Bagchi, P., & Kalluri, R. M. (2010) · Physical Review E · doi:10.1103/physreve.81.056320 · Cited by 51
Effect of inertia on the hydrodynamic interaction between two liquid capsules in simple shear flow
Doddi, S. K., & Bagchi, P. (2007) · International Journal of Multiphase Flow · doi:10.1016/j.ijmultiphaseflow.2007.10.011 · Cited by 50
Off-plane motion of a prolate capsule in shear flow
Dupont, C., Salsac, A., & Barthès‐Biesel, D. (2013) · Journal of Fluid Mechanics · doi:10.1017/jfm.2013.62 · Cited by 45 · cited 1×
“Using a thin-shell model under the more general Reissner-Mindlin approximation, Dupont et al. (2015) systematically studied the influence of the bending number B on the deformation of an artificial capsule.”
MethodSelf-citationLarge deformation of liquid capsules enclosed by thin shells immersed in the fluid
Le, D. V., & Tan, Z. (2010) · Journal of Computational Physics · doi:10.1016/j.jcp.2010.01.042 · Cited by 41
Numerical simulation of capsule deformation in simple shear flow
Sui, Y., CHEN, X. B., Chew, Y. T., Roy, P., & Low, H. T. (2009) · Computers & Fluids · doi:10.1016/j.compfluid.2009.09.001 · Cited by 34
Metadata
- Authors
- Barthès-Biesel, D.
- Venue
- Annual Review of Fluid Mechanics
- Publisher
- Annual Reviews
- Published
- 2016-01-03
- Volume
- 48
- Issue
- 1
- Pages
- 25-52
- ISSN
- 0066-4189 (ISSN-L)
- 1545-4479
- OpenAlex
- W2236024854
- Cited by
- 213
- References
- 44
- FWCI
- 14.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.