Droplets and Bubbles in Microfluidic Devices
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
Precise, tunable emulsions and foams produced in microfluidic geometries have found wide application in biochemical analysis and materials synthesis and characterization. Superb control of the volume, uniformity, and generation rate of droplets and bubbles arises from unique features of the microscale behavior of fluid interfaces. Fluid interfaces confined within microfluidic channels behave quite differently than their counterparts in unbounded flows. Confinement inhibits capillary instabilities so that breakup occurs by largely quasi-static mechanisms. The three-dimensional flow near confined interfaces in rectangular geometries and feedback effects from resistance changes in the entire microfluidic network play important roles in regulating the interfacial deformation. Timescales for transport of surfactants and particles to interfaces compete with flow timescales at the microscale, providing further opportunity for tuning the interfacial coverage and properties of individual droplets and bubbles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Particles as surfactants—similarities and differences
Binks, B. P. (2002) · Current Opinion in Colloid & Interface Science · doi:10.1016/s1359-0294(02)00008-0 · Cited by 3,691
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
The formation of emulsions in definable fields of flow
Taylor, G. I. (1934) · Proceedings of the Royal Society of London. Series A, Containing Papers of a Mathematical and Physical Character · doi:10.1098/rspa.1934.0169 · Cited by 2,500
Formation of droplets and bubbles in a microfluidic T-junction—scaling and mechanism of break-up
Garstecki, P., Fuerstman, M. J., Stone, H. A., & Whitesides, G. M. (2006) · Lab on a Chip · doi:10.1039/b510841a · Cited by 2,339
Formation of dispersions using “flow focusing” in microchannels
Anna, S. L., Bontoux, N., & Stone, H. A. (2003) · Applied Physics Letters · doi:10.1063/1.1537519 · Cited by 2,302
Self-citationVI. On the capillary phenomena of jets
Strutt, J. W. (1879) · Proceedings of the Royal Society of London · doi:10.1098/rspl.1879.0015 · Cited by 2,078
Dynamic Pattern Formation in a Vesicle-Generating Microfluidic Device
Thorsen, T., Roberts, R. W., Arnold, F. H., & Quake, S. R. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.4163 · Cited by 2,051
Reactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
Eggers, J., & Villermaux, E. (2008) · Reports on Progress in Physics · doi:10.1088/0034-4885/71/3/036601 · Cited by 1,827
Geometrically Mediated Breakup of Drops in Microfluidic Devices
Link, D. R., Anna, S. L., Weitz, D. A., & Stone, H. A. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.054503 · Cited by 1,202
Self-citation
Cited by
Passive and active droplet generation with microfluidics: a review
Zhu, P., & Wang, L. (2017) · Lab on a Chip · doi:10.1039/c6lc01018k · Cited by 1,238
Formulation, stabilisation and encapsulation of bacteriophage for phage therapy
Malik, D. J., Sokolov, I. J., Vinner, G. K., Mancuso, F., Cinquerrui, S., Vladisavljevic, G. T., Clokie, M. R. J., Garton, N. J., Stapley, A. G. F., & Kirpichnikova, A. (2017) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2017.05.014 · Cited by 594
“The most common planar DGUs are co-flow drop makers in which immiscible fluids meet in parallel streams, cross-flow drop makers or microfluidic junctions in which the immiscible fluid streams meet at an angle to one another, and flow-focusing drop makers in which there is a geometric element, such as a constriction, t…”
BackgroundYe, T., Pan, D., Huang, C., & Liu, M. (2019) · Physics of Fluids · doi:10.1063/1.5068697 · Cited by 423
Ho, T. M., Razzaghi, A., Ramachandran, A., & Mikkonen, K. S. (2022) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2021.102541 · Cited by 253
Machine learning enables design automation of microfluidic flow-focusing droplet generation
Lashkaripour, A., Rodriguez, C., Mehdipour, N., Mardian, R., McIntyre, D., Ortiz, L., Campbell, J., & Densmore, D. (2021) · Nature Communications · doi:10.1038/s41467-020-20284-z · Cited by 236
Gut-on-a-chip: Current progress and future opportunities
Ashammakhi, N., Nasiri, R., Barros, N. R. D., Tebon, P., Thakor, J., Goudie, M., Shamloo, A., Martin, M. G., & Khademhosseini, A. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.120196 · Cited by 235
Kidney-on-a-chip: untapped opportunities
Ashammakhi, N., Wesseling-Perry, K., Hasan, A., Elkhammas, E., & Zhang, Y. S. (2018) · Kidney International · doi:10.1016/j.kint.2018.06.034 · Cited by 175
Droplet-based microfluidics in biomedical applications
Amirifar, L., Besanjideh, M., Nasiri, R., Shamloo, A., Nasrollahi, F., de Barros, N. R., Davoodi, E., Erdem, A., Mahmoodi, M., Hosseini, V., et al. (2022) · Biofabrication · doi:10.1088/1758-5090/ac39a9 · Cited by 174
“In this process, the interface of the continuous and dispersed phases is deformed, leading to pinching off the dispersed phase and droplet generation [14, 15].”
Dripping, jetting and tip streaming
Montanero, J. M., & Gañán-Calvo, A. M. (2020) · Reports on Progress in Physics · doi:10.1088/1361-6633/aba482 · Cited by 168
“The breakup of jets becomes a rich and intricate problem when complex liquids (Anna, 2016) are considered.”
BackgroundInfluentialMachine learning for microfluidic design and control
McIntyre, D., Lashkaripour, A., Fordyce, P., & Densmore, D. (2022) · Lab on a Chip · doi:10.1039/d2lc00254j · Cited by 166
Recent Advances in the Analysis of Single Cells
Armbrecht, L., & Dittrich, P. S. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04255 · Cited by 164
Emulsions in porous media: From single droplet behavior to applications for oil recovery
Perazzo, A., Tomaiuolo, G., Preziosi, V., & Guido, S. (2018) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2018.03.002 · Cited by 162
Metadata
- Authors
- Anna, S. L.
- Venue
- Annual Review of Fluid Mechanics
- Publisher
- Annual Reviews
- Published
- 2016-01-03
- Volume
- 48
- Issue
- 1
- Pages
- 285-309
- ISSN
- 0066-4189 (ISSN-L)
- 1545-4479
- OpenAlex
- W1910197149
- Cited by
- 582
- References
- 43
- FWCI
- 3.39
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.