Application of Microphysiological Systems to Enhance Safety Assessment in Drug Discovery
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Enhancing the early detection of new therapies that are likely to carry a safety liability in the context of the intended patient population would provide a major advance in drug discovery. Microphysiological systems (MPS) technology offers an opportunity to support enhanced preclinical to clinical translation through the generation of higher-quality preclinical physiological data. In this review, we highlight this technological opportunity by focusing on key target organs associated with drug safety and metabolism. By focusing on MPS models that have been developed for these organs, alongside other relevant in vitro models, we review the current state of the art and the challenges that still need to be overcome to ensure application of this technology in enhancing drug discovery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Single Lgr5 stem cells build crypt-villus structures in vitro without a mesenchymal niche
Sato, T., Vries, R. G., Snippert, H. J., van de Wetering, M., Barker, N., Stange, D. E., van Es, J. H., Abo, A., Kujala, P., Peters, P. J., et al. (2009) · Nature · doi:10.1038/nature07935 · Cited by 7,204 · cited 1×
“Several complex human intestinal models have been developed, including organoid models, which have been used successfully to determine risk assessment profiles (84, 85).”
BackgroundReconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250 · cited 1×
“By introducing stretch, researchers demonstrated in vivo–like properties (74).”
BackgroundCan the pharmaceutical industry reduce attrition rates?
Kola, I., & Landis, J. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1470 · Cited by 4,167
The gut microbiota--masters of host development and physiology
Sommer, F., & Bäckhed, F. (2013) · Nature Reviews Microbiology · doi:10.1038/nrmicro2974 · Cited by 3,681
Clinical development success rates for investigational drugs
Hay, M., Thomas, D. W., Craighead, J. L., Economides, C., & Rosenthal, J. (2014) · Nature Biotechnology · doi:10.1038/nbt.2786 · Cited by 2,536
From 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834
Intestinal barrier function: molecular regulation and disease pathogenesis
Groschwitz, K. R., & Hogan, S. P. (2009) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2009.05.038 · Cited by 1,775
Claycomb, W. C., Lanson, N. A., Stallworth, B. S., Egeland, D. B., Delcarpio, J. B., Bahinski, A., & Izzo, N. J. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.6.2979 · Cited by 1,546 · cited 1×
“To date, this has focused on overexpressing cell lines; rat myoblast H9c2 cells that exhibit a skeletal muscle phenotype (40); mouse HL-1 cells (atrial phenotype) (41), which lack the mature cardiomyocyte phenotype; and isolated cardiomyocytes from preclinical species, which undergo dedifferentiation.”
BackgroundGodoy, P., Hewitt, N. J., Albrecht, U., Andersen, M. E., Ansari, N., Bhattacharya, S., Bode, J. G., Bolleyn, J., Borner, C., Böttger, J., et al. (2013) · Archives of Toxicology · doi:10.1007/s00204-013-1078-5 · Cited by 1,280 · cited 1×
“The phenotypic and functional stability of these 3-D platforms is facilitated by cell-cell communication and maintenance of cell polarity in combination with extracellular matrix composition that better mimics the intact organ (22, 23).”
BackgroundMicroscale culture of human liver cells for drug development
Khetani, S. R., & Bhatia, S. N. (2008) · Nature Biotechnology · doi:10.1038/nbt1361 · Cited by 1,219 · cited 1×
“The micropatterned coculture system, in which hepatocytes are cocultured with fibroblasts, is possibly the most extensively characterized of such platforms, and hepatocytes in such systems maintain expression of relevant enzymes for multiple weeks (28).”
Background
Cited by
Robotic fluidic coupling and interrogation of multiple vascularized organ chips
Novak, R., Ingram, M., Marquez, S., Das, D., Delahanty, A., Herland, A., Maoz, B. M., Jeanty, S. S. F., Somayaji, M. R., Burt, M., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0497-x · Cited by 427
Self-citationBell, C. C., Dankers, A. C. A., Lauschke, V. M., Sison-Young, R., Jenkins, R., Rowe, C., Goldring, C. E., Park, K., Regan, S. L., Walker, T., et al. (2018) · Toxicological Sciences · doi:10.1093/toxsci/kfx289 · Cited by 327
Self-citationRecent Advances in Body-on-a-Chip Systems
Sung, J. H., Wang, Y. I., Narasimhan Sriram, N., Jackson, M., Long, C., Hickman, J. J., & Shuler, M. L. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b05293 · Cited by 268
Self-citationUse of precision cut lung slices as a translational model for the study of lung biology
Liu, G., Betts, C., Cunoosamy, D. M., Åberg, P. M., Hornberg, J. J., Sivars, K. B., & Cohen, T. S. (2019) · Respiratory Research · doi:10.1186/s12931-019-1131-x · Cited by 206
Vorrink, S. U., Zhou, Y., Ingelman-Sundberg, M., & Lauschke, V. M. (2018) · Toxicological Sciences · doi:10.1093/toxsci/kfy058 · Cited by 187
Self-citation
Metadata
- Authors
- Ewart, L., Dehne, E.-M., Fabre, K., Gibbs, S., Hickman, J., Hornberg, E., Ingelman-Sundberg, M., Jang, K.-J., Jones, D. R., Lauschke, V. M., Marx, U., Mettetal, J. T., Pointon, A., Williams, D., Zimmermann, W.-H., & Newham, P.
- Venue
- Annual Review of Pharmacology and Toxicology
- Publisher
- Annual Reviews
- Published
- 2018-01-06
- Volume
- 58
- Issue
- 1
- Pages
- 65-82
- ISSN
- 0362-1642 (ISSN-L)
- 1545-4304
- OpenAlex
- W2613431810
- Cited by
- 128
- References
- 40
- FWCI
- 1.49
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Application of Microphysiological Systems to Enhance Safety Assessment in Drug Discovery. https://app.cochat.ai/papers/10.1146/annurev-pharmtox-010617-052722
- The paper
- Ewart, L., Dehne, E.-M., Fabre, K., Gibbs, S., Hickman, J., Hornberg, E., Ingelman-Sundberg, M., Jang, K.-J., Jones, D. R., Lauschke, V. M., Marx, U., Mettetal, J. T., Pointon, A., Williams, D., Zimmermann, W.-H., & Newham, P. (2018). Application of Microphysiological Systems to Enhance Safety Assessment in Drug Discovery. Annual Review of Pharmacology and Toxicology. https://doi.org/10.1146/annurev-pharmtox-010617-052722
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.