Ion Mobility Analysis of Molecular Dynamics
The DOI matches its Crossref record; 85 of the 85 references it cites were found in a registry or an index.
Abstract
The combination of mass spectrometry and ion mobility spectrometry (IMS) employing a temperature-variable drift cell or a drift tube divided into sections to make IMS-IMS experiments possible allows information to be obtained about the molecular dynamics of polyatomic ions in the absence of a solvent. The experiments allow the investigation of structural changes of both activated and native ion populations on a timescale of 1–100 ms. Five different systems representing small and large, polar and nonpolar molecules, as well as noncovalent assemblies, are discussed in detail: a dinucleotide, a sodiated polyethylene glycol chain, the peptide bradykinin, the protein ubiquitin, and two types of peptide oligomers. Barriers to conformational interconversion can be obtained in favorable cases. In other cases, solution-like native structures can be observed, but care must be taken in the experimental protocols. The power of theoretical modeling is demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prusiner, S. B. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.23.13363 · Cited by 5,373
MOPAC: A semiempirical molecular orbital program
Stewart, J. J. P. (1990) · Journal of Computer-Aided Molecular Design · doi:10.1007/bf00128336 · Cited by 2,897 · cited 1×
“Employing RRKM (Rice-Ramsperger-Kassel-Marcus) theory (17) and semiempirical calculations (18) for obtaining vibrational frequencies is a strategy for estimating the density of states of both conformations at an energy level corresponding to the top of the barrier.”
MethodStructure of the cross-β spine of amyloid-like fibrils
Nelson, R., Sawaya, M. R., Balbirnie, M., Madsen, A. Ø., Riekel, C., Grothe, R., & Eisenberg, D. (2005) · Nature · doi:10.1038/nature03680 · Cited by 2,202
Ashmore, P. G., & Robinson, P. J. (1975) · Reaction Kinetics · doi:10.1039/9781847556899-00093 · Cited by 1,979
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930 · cited 25×
“The native structure state is stable in aqueous solutions to 100◦C. Early on, ESI-MS work on proteins indicated a close correlation between the protein charge state distribution in the mass spectrum and the ESI solution conditions, with denaturing conditions yielding high charge states and native conditions lower char…”
BackgroundMethodInfluentialTransport Properties of Ions in Gases
Mason, E. A., & McDaniel, E. W. (1988) · Wiley eBooks · doi:10.1002/3527602852 · Cited by 1,797
Structure of ubiquitin refined at 1.8 Å resolution
Vijay-kumar, S., Bugg, C. E., & Cook, W. J. (1987) · Journal of Molecular Biology · doi:10.1016/0022-2836(87)90679-6 · Cited by 1,742 · cited 1×
“Ubiquitin is a 76-residue protein in which two helices, a five-stranded β-sheet, and seven reverse turns compose the native structure (57); a more extended and highly helical A state (58) forms in low-pH solutions of >40% methanol (Figure 5a,b), and an unstructured solution state has also been reported.”
BackgroundBernstein, S. L., Dupuis, N. F., Lazo, N. D., Wyttenbach, T., Condron, M. M., Bitan, G., Teplow, D. B., Shea, J.-E., Ruotolo, B. T., Robinson, C. V., et al. (2009) · Nature Chemistry · doi:10.1038/nchem.247 · Cited by 918
Self-citatione Silva, M. R., Beraldo, W. T., & Rosenfeld, G. (1949) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1949.156.2.261 · Cited by 825 · cited 1×
“Here, we focus on bradykinin (BK) (35, 36) with the sequence RPPGFSPFR and specifically on its charge state +3.”
BackgroundAn exact hard-spheres scattering model for the mobilities of polyatomic ions
Shvartsburg, A. A., & Jarrold, M. F. (1996) · Chemical Physics Letters · doi:10.1016/0009-2614(96)00941-4 · Cited by 819 · cited 1×
“of 1,000 Å2? The solution structure yields a predicted cross section in helium of 1,150 Å2 (53, 68).”
Background
Cited by
Software Tools and Approaches for Compound Identification of LC-MS/MS Data in Metabolomics
Blaženović, I., Kind, T., Ji, J., & Fiehn, O. (2018) · Metabolites · doi:10.3390/metabo8020031 · Cited by 757
Native Mass Spectrometry: What is in the Name?
Leney, A. C., & Heck, A. J. R. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1545-3 · Cited by 602
“Since then, IMS-MS has been successfully applied to monitor protein conformational changes [67, 68] and to gain information on how proteins assemble/misassemble into large macromolecular complexes [69–71].”
MethodRecommendations for reporting ion mobility Mass Spectrometry measurements
Gabelica, V., Shvartsburg, A. A., Afonso, C., Barran, P., Benesch, J. L. P., Bleiholder, C., Bowers, M. T., Bilbao, A., Bush, M. F., Campbell, J. L., et al. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21585 · Cited by 493
“…increasingly prominent in structural biology (Politis et al., 2010; Konijnenberg, Butterer, & Sobott, 2013; Thalassinos et al., 2013; Marklund et al., 2015; Ben-Nissan & Sharon, 2018), structural chemistry (Ujma et al., 2012; Surman et al., 2016) and physical chemistry (Wyttenbach et al., 2014).”
Self-citationIon Mobility-Mass Spectrometry: Time-Dispersive Instrumentation
May, J. C., & McLean, J. A. (2015) · Analytical Chemistry · doi:10.1021/ac504720m · Cited by 435
Collision Cross Sections for Structural Proteomics
Marklund, E. G., Degiacomi, M. T., Robinson, C. V., Baldwin, A. J., & Benesch, J. L. P. (2015) · Structure · doi:10.1016/j.str.2015.02.010 · Cited by 270
Deng, L., Webb, I. K., Garimella, S. V. B., Hamid, A. M., Zheng, X., Norheim, R. V., Prost, S. A., Anderson, G. A., Sandoval, J. A., Baker, E. S., et al. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00185 · Cited by 228
Wongkongkathep, P., Han, J. Y., Choi, T. S., Yin, S., Kim, H. I., & Loo, J. A. (2018) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-018-2002-2 · Cited by 71
“Ion mobility mass spectrometry (IM-MS) provided additional structural and conformation information that may play a role in amyloid fibrillation [8, 64].”
Ion mobility in the pharmaceutical industry: an established biophysical technique or still niche?
Campuzano, I. D., & Lippens, J. L. (2018) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2017.11.008 · Cited by 42
Allison, T. M., Barran, P., Cianférani, S., Degiacomi, M. T., Gabelica, V., Grandori, R., Marklund, E. G., Menneteau, T., Migas, L. G., Politis, A., et al. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05791 · Cited by 38
Metadata
- Authors
- Wyttenbach, T., Pierson, N. A., Clemmer, D. E., & Bowers, M. T.
- Venue
- Annual Review of Physical Chemistry
- Publisher
- Annual Reviews
- Published
- 2014-04-01
- Volume
- 65
- Issue
- 1
- Pages
- 175-196
- ISSN
- 0066-426X (ISSN-L)
- 1545-1593
- OpenAlex
- W2128338912
- Cited by
- 189
- References
- 85
- FWCI
- 1.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.