Electrochemical Impedance Spectroscopy
The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
This review describes recent advances in electrochemical impedance spectroscopy (EIS) with an emphasis on its novel applications to various electrochemistry-related problems. Section 1 discusses the development of new EIS techniques to reduce measurement time. For this purpose, various forms of multisine EIS techniques were first developed via a noise signal synthesized by mixing ac waves of various frequencies, followed by fast Fourier transform of the signal and the resulting current. Subsequently, an entirely new concept was introduced in which true white noise was used as an excitation source, followed by Fourier transform of both excitation and response signals. Section 2 describes novel applications of the newly developed techniques to time-resolved impedance measurements as well as to impedance imaging. Section 3 is devoted to recent applications of EIS techniques, specifically traditional measurements in various fields with a special emphasis on biosensor detections.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Methods: Fundamentals and Applications
de Rooij, D. M. R. (2003) · Anti-Corrosion Methods and Materials · doi:10.1108/acmm.2003.12850eae.001 · Cited by 13,009
Drummond, T. G., Hill, M. G., & Barton, J. K. (2003) · Nature Biotechnology · doi:10.1038/nbt873 · Cited by 2,214
Electrochemical Impedance Spectroscopic Analysis of Dye-Sensitized Solar Cells
Wang, Q., Moser, J.-E., & Grätzel, M. (2005) · The Journal of Physical Chemistry B · doi:10.1021/jp052768h · Cited by 2,002
Kinetics of rapid electrode reactions
Randles, J. E. B. (1947) · Discussions of the Faraday Society · doi:10.1039/df9470100011 · Cited by 1,884
Electrochemical Impedance Spectroscopy
Orazem, M. E., & Tribollet, B. (2008) · Wiley eBooks · doi:10.1002/9780470381588 · Cited by 1,676
Electrochemical Impedance Spectroscopy
(2016) · Encyclopedia of Membranes · doi:10.1007/978-3-662-44324-8_100089 · Cited by 1,580
Label‐Free Impedance Biosensors: Opportunities and Challenges
Daniels, J. S., & Pourmand, N. (2007) · Electroanalysis · doi:10.1002/elan.200603855 · Cited by 1,192
Fabregat-Santiago, F., Bisquert, J., Garcia-Belmonte, G., Boschloo, G., & Hagfeldt, A. (2005) · Solar Energy Materials and Solar Cells · doi:10.1016/j.solmat.2004.07.017 · Cited by 1,179
Reflections on the history of electrochemical impedance spectroscopy
Macdonald, D. D. (2006) · Electrochimica Acta · doi:10.1016/j.electacta.2005.02.107 · Cited by 1,001
Fabregat-Santiago, F., Bisquert, J., Palomares, E., Otero, L., Kuang, D., Zakeeruddin, S. M., & Grätzel, M. (2007) · The Journal of Physical Chemistry C · doi:10.1021/jp066178a · Cited by 906
Cited by
Cancer biomarker detection: recent achievements and challenges
Wu, L., & Qu, X. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00370e · Cited by 1,214
Electrochemical impedance spectroscopy
Wang, S., Zhang, J., Gharbi, O., Vivier, V., Gao, M., & Orazem, M. E. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00039-w · Cited by 1,140
Applications of Phosphorene and Black Phosphorus in Energy Conversion and Storage Devices
Pang, J., Bachmatiuk, A., Yin, Y., Trzebicka, B., Zhao, L., Fu, L., Mendes, R. G., Gemming, T., Liu, Z., & Rummeli, M. H. (2018) · Advanced Energy Materials · doi:10.1002/aenm.201702093 · Cited by 518
Zou, C., Zhang, L., Hu, X., Wang, Z., Wik, T., & Pecht, M. (2018) · Journal of Power Sources · doi:10.1016/j.jpowsour.2018.04.033 · Cited by 515
Guo, T., Li, L., & Wang, Z. (2022) · Advanced Energy Materials · doi:10.1002/aenm.202200827 · Cited by 497
Research advances in the detection of miRNA
Ye, J., Xu, M., Tian, X., Cai, S., & Zeng, S. (2019) · Journal of Pharmaceutical Analysis · doi:10.1016/j.jpha.2019.05.004 · Cited by 440
Characterization of semiconductor photocatalysts
Zhang, L., Ran, J., Qiao, S.-Z., & Jaroniec, M. (2019) · Chemical Society Reviews · doi:10.1039/c9cs00172g · Cited by 430
Bioelectrical Impedance Methods for Noninvasive Health Monitoring: A Review
Bera, T. K. (2014) · Journal of Medical Engineering · doi:10.1155/2014/381251 · Cited by 407
Huang, J., Li, Z., Liaw, B. Y., & Zhang, J. (2016) · Journal of Power Sources · doi:10.1016/j.jpowsour.2016.01.073 · Cited by 399
Electrical impedance spectroscopy (EIS) for biological analysis and food characterization: a review
Grossi, M., & Riccò, B. (2017) · Journal of Sensors and Sensor Systems · doi:10.5194/jsss-6-303-2017 · Cited by 394
Zhu, X., Liu, B., Hou, H., Huang, Z., Zeinu, K. M., Huang, L., Yuan, X., Guo, D., Hu, J., & Yang, J. (2017) · Electrochimica Acta · doi:10.1016/j.electacta.2017.07.084 · Cited by 388
Electrochemistry, biosensors and microfluidics: a convergence of fields
Rackus, D. G., Shamsi, M. H., & Wheeler, A. R. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00369a · Cited by 354
Stress Biomarkers in Biological Fluids and Their Point-of-Use Detection
Steckl, A. J., & Ray, P. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00726 · Cited by 319
Dong, H., Jin, X., Lou, Y., & Wang, C. (2014) · Journal of Power Sources · doi:10.1016/j.jpowsour.2014.07.176 · Cited by 310
Effat, M. B., & Ciucci, F. (2017) · Electrochimica Acta · doi:10.1016/j.electacta.2017.07.050 · Cited by 295
Antibody fragments as nanoparticle targeting ligands: a step in the right direction
Richards, D. A., Maruani, A., & Chudasama, V. (2017) · Chemical Science · doi:10.1039/c6sc02403c · Cited by 294
Feng, T., Yang, L., Zhao, X., Zhang, H., & Qiang, J. (2015) · Journal of Power Sources · doi:10.1016/j.jpowsour.2015.01.154 · Cited by 285
A Review on Advanced FeNi-Based Catalysts for Water Splitting Reaction
Li, D., Liu, H., & Feng, L. (2020) · Energy & Fuels · doi:10.1021/acs.energyfuels.0c03084 · Cited by 256
Perdana, M. Y., Johan, B. A., Abdallah, M., Hossain, M. E., Aziz, M. A., Baroud, T. N., & Drmosh, Q. A. (2024) · The Chemical Record · doi:10.1002/tcr.202400007 · Cited by 245
Advances in Biosensors and Diagnostic Technologies Using Nanostructures and Nanomaterials
Welch, E. C., Powell, J. M., Clevinger, T. B., Fairman, A. E., & Shukla, A. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202104126 · Cited by 240
Hernandez-Vargas, G., Sosa-Hernández, J., Saldarriaga-Hernandez, S., Villalba-Rodríguez, A., Parra-Saldivar, R., & Iqbal, H. (2018) · Biosensors · doi:10.3390/bios8020029 · Cited by 240
“EIS is a powerful tool since this technique evaluates the intrinsic material or system property of impedance, which is of high importance to biosensor development and applications [34].”
MethodLei, Y., Butler, D., Lucking, M. C., Zhang, F., Xia, T., Fujisawa, K., Granzier-Nakajima, T., Cruz-Silva, R., Endo, M., Terrones, H., et al. (2020) · Science Advances · doi:10.1126/sciadv.abc4250 · Cited by 238
Shin, S. R., Zhang, Y. S., Kim, D.-J., Manbohi, A., Avci, H., Silvestri, A., Aleman, J., Hu, N., Kilic, T., Keung, W., et al. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b02028 · Cited by 233
Conducting polymer based electrochemical biosensors
Aydemir, N., Malmström, J., & Travas-Sejdic, J. (2016) · Physical Chemistry Chemical Physics · doi:10.1039/c5cp06830d · Cited by 224
Layered Black Phosphorus as a Selective Vapor Sensor
Mayorga‐Martinez, C. C., Sofer, Z., & Pumera, M. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201505015 · Cited by 217
Menon, S., Mathew, M. R., Sam, S., Keerthi, K., & Kumar, K. G. (2020) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2020.114596 · Cited by 212
“-Electrochemists have been familiar with the Electrochemical Impedance Spectroscopic (EIS) technique for over a century [57].”
Bondarenko, A. S., Stephens, I. E. L., Hansen, H. A., Pérez-Alonso, F. J., Tripkovic, V., Johansson, T. P., Rossmeisl, J., Nørskov, J. K., & Chorkendorff, I. (2011) · Langmuir · doi:10.1021/la1042475 · Cited by 207
Huang, J., Gao, Y., Luo, J., Wang, S., Li, C., Chen, S., & Zhang, J. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/abc655 · Cited by 204
Balogun, M.-S., Yu, M., Huang, Y., Li, C., Fang, P., Liu, Y., Lu, X., & Tong, Y. (2015) · Nano Energy · doi:10.1016/j.nanoen.2014.11.019 · Cited by 187
Covalent organic framework based lithium-ion battery: Fundamental, design and characterization
Hu, Y., Wayment, L. J., Haslam, C., Yang, X., Lee, S.-H., Jin, Y., & Zhang, W. (2021) · EnergyChem · doi:10.1016/j.enchem.2020.100048 · Cited by 179
Shen, L., Jiang, Y., Liu, Y., Ma, J., Sun, T., & Zhu, N. (2020) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.124228 · Cited by 169
Nano-biosensors to detect beta-amyloid for Alzheimer's disease management
Kaushik, A., Jayant, R. D., Tiwari, S., Vashist, A., & Nair, M. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.01.065 · Cited by 165
Park, D.-W., Ness, J. P., Brodnick, S. K., Esquibel, C., Novello, J., Atry, F., Baek, D.-H., Kim, H., Bong, J., Swanson, K. I., et al. (2018) · ACS Nano · doi:10.1021/acsnano.7b04321 · Cited by 165
Label-free electrochemical DNA biosensor for zika virus identification
Faria, H. A. M., & Zucolotto, V. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.02.018 · Cited by 165
Determining the Dielectric Constants of Organic Photovoltaic Materials Using Impedance Spectroscopy
Hughes, M. P., Rosenthal, K. D., Ran, N. A., Seifrid, M., Bazan, G. C., & Nguyen, T. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201801542 · Cited by 162
Detecting Biothreat Agents: From Current Diagnostics to Developing Sensor Technologies
Walper, S. A., Lasarte Aragonés, G., Sapsford, K. E., Brown, C. W., Rowland, C. E., Breger, J. C., & Medintz, I. L. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00420 · Cited by 161
Geophysical Properties of the Near Surface Earth: Electrical Properties
Glover, P. W. J. (2015) · Treatise on Geophysics · doi:10.1016/b978-0-444-53802-4.00189-5 · Cited by 160
Jagannath, B., Muthukumar, S., & Prasad, S. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.02.013 · Cited by 56
Metadata
- Authors
- Chang, B.-Y., & Park, S.-M.
- Venue
- Annual Review of Analytical Chemistry
- Publisher
- Annual Reviews
- Published
- 2010-06-01
- Volume
- 3
- Issue
- 1
- Pages
- 207-229
- ISSN
- 1936-1327 (ISSN-L)
- 1936-1335
- OpenAlex
- W2171543143
- Cited by
- 1,248
- References
- 48
- FWCI
- 2.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.