Ambient Ionization Mass Spectrometry
The DOI matches its Crossref record; 60 of the 60 references it cites were found in a registry or an index.
Abstract
Mass spectrometric ionization methods that operate under ambient conditions and require minimal or no sample pretreatment have attracted much attention in such fields as biomedicine, food safety, antiterrorism, pharmaceuticals, and environmental pollution. These technologies usually involve separate ionization and sample-introduction events, allowing independent control over each set of conditions. Ionization is typically performed under ambient conditions through use of existing electrospray ionization (ESI) or atmospheric pressure chemical ionization (APCI) techniques. Rapid analyses of gas, liquid, and solid samples are possible with the adoption of various sample-introduction methods. This review sorts different ambient ionization techniques into two main subcategories, primarily on the basis of the ionization processes, that are further differentiated in terms of the approach used for sampling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mass Spectrometry Sampling Under Ambient Conditions with Desorption Electrospray Ionization
Takáts, Z., Wiseman, J. M., Gologan, B., & Cooks, R. G. (2004) · Science · doi:10.1126/science.1104404 · Cited by 3,324
Versatile New Ion Source for the Analysis of Materials in Open Air under Ambient Conditions
Cody, R. B., Laramée, J. A., & Durst, H. D. (2005) · Analytical Chemistry · doi:10.1021/ac050162j · Cited by 2,483
Electrospray ion source. Another variation on the free-jet theme
Yamashita, M., & Fenn, J. B. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150664a002 · Cited by 2,082
Cooks, R. G., Ouyang, Z., Takats, Z., & Wiseman, J. M. (2006) · Science · doi:10.1126/science.1119426 · Cited by 1,474
Electrospray ionization mass spectrometry : fundamentals, instrumentation, and applications
Cole, R. B. (1997) · Wiley eBooks · Cited by 1,140
Fast atom bombardment of solids (F.A.B.): a new ion source for mass spectrometry
Barber, M., Bordoli, R. S., Sedgwick, R. D., & Tyler, A. N. (1981) · Journal of the Chemical Society, Chemical Communications · doi:10.1039/c39810000325 · Cited by 1,106
Takáts, Z., Wiseman, J. M., & Cooks, R. G. (2005) · Journal of Mass Spectrometry · doi:10.1002/jms.922 · Cited by 880
Nemes, P., & Vertes, A. (2007) · Analytical Chemistry · doi:10.1021/ac071181r · Cited by 817
Robb, D. B., Covey, T. R., & Bruins, A. P. (2000) · Analytical Chemistry · doi:10.1021/ac0001636 · Cited by 748
Low-Temperature Plasma Probe for Ambient Desorption Ionization
Harper, J. D., Charipar, N. A., Mulligan, C. C., Zhang, X., Cooks, R. G., & Ouyang, Z. (2008) · Analytical Chemistry · doi:10.1021/ac801641a · Cited by 730
Cited by
Ambient Sampling/Ionization Mass Spectrometry: Applications and Current Trends
Harris, G. A., Galhena, A. S., & Fernández, F. M. (2011) · Analytical Chemistry · doi:10.1021/ac200918u · Cited by 527
Mass spectrometry imaging under ambient conditions
Wu, C., Dill, A. L., Eberlin, L. S., Cooks, R. G., & Ifa, D. R. (2013) · Mass Spectrometry Reviews · doi:10.1002/mas.21360 · Cited by 488
Mass Spectrometry: Recent Advances in Direct Open Air Surface Sampling/Ionization
Monge, M. E., Harris, G. A., Dwivedi, P., & Fernández, F. M. (2013) · Chemical Reviews · doi:10.1021/cr300309q · Cited by 476
Ambient ionization mass spectrometry: A tutorial
Huang, M.-Z., Cheng, S.-C., Cho, Y.-T., & Shiea, J. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.06.017 · Cited by 320
Self-citationA review of recent, unconventional applications of ion mobility spectrometry (IMS)
Armenta, S., Alcala, M., & Blanco, M. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.07.021 · Cited by 234
Electrospray Ionization Using Wooden Tips
Hu, B., So, P.-K., Chen, H., & Yao, Z.-P. (2011) · Analytical Chemistry · doi:10.1021/ac2017713 · Cited by 217
Spray mechanism in paper spray ionization
Espy, R. D., Muliadi, A. R., Ouyang, Z., & Cooks, R. G. (2012) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2012.06.017 · Cited by 178
Profiling and quantifying endogenous molecules in single cells using nano-DESI MS
Bergman, H.-M., & Lanekoff, I. (2017) · The Analyst · doi:10.1039/c7an00885f · Cited by 109
Developing a Cell Quenching Method to Facilitate Single Cell Mass Spectrometry Metabolomics Studies
Wije Munige, S., Bhusal, D., Peng, Z., Chen, D., & Yang, Z. (2025) · JACS Au · doi:10.1021/jacsau.5c00327 · Cited by 11
Metadata
- Authors
- Huang, M.-Z., Yuan, C.-H., Cheng, S.-C., Cho, Y.-T., & Shiea, J.
- Venue
- Annual Review of Analytical Chemistry
- Publisher
- Annual Reviews
- Published
- 2010-06-01
- Volume
- 3
- Issue
- 1
- Pages
- 43-65
- ISSN
- 1936-1327 (ISSN-L)
- 1936-1335
- OpenAlex
- W2159199618
- Cited by
- 306
- References
- 60
- FWCI
- 1.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.