Robotics for Surgery
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
▪ Abstract Robotic technology is enhancing surgery through improved precision, stability, and dexterity. In image-guided procedures, robots use magnetic resonance and computed tomography image data to guide instruments to the treatment site. This requires new algorithms and user interfaces for planning procedures; it also requires sensors for registering the patient’s anatomy with the preoperative image data. Minimally invasive procedures use remotely controlled robots that allow the surgeon to work inside the patient’s body without making large incisions. Specialized mechanical designs and sensing technologies are needed to maximize dexterity under these access constraints. Robots have applications in many surgical specialties. In neurosurgery, image-guided robots can biopsy brain lesions with minimal damage to adjacent tissue. In orthopedic surgery, robots are routinely used to shape the femur to precisely fit prosthetic hip joint replacements. Robotic systems are also under development for closed-chest heart bypass, for microsurgical procedures in ophthalmology, and for surgical training and simulation. Although results from initial clinical experience is positive, issues of clinician acceptance, high capital costs, performance validation, and safety remain to be addressed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Robotics mechanics and Control
Craig, J. (1986) · Cited by 5,024
A tutorial on visual servo control
Hutchinson, S., Hager, G. D., & Corke, P. I. (1996) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.538972 · Cited by 3,528
Telerobotics, Automation, and Human Supervisory Control
Sheridan, T. B. (1992) · Medical Entomology and Zoology · Cited by 1,949
A robot with improved absolute positioning accuracy for CT guided stereotactic brain surgery
Kwoh, Y. S., Hou, J., Jonckheere, E. A., & Hayati, S. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.1354 · Cited by 1,278
Adaptive segmentation of MRI data
Wells, W. M., Grimson, W. E. L., Kikinis, R., & Jolesz, F. A. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.511747 · Cited by 1,277
Primary and Revision Total Hip Replacement Using the Robodoc?? System
Bargar, W. L., Bauer, A., & B??rner, M. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199809000-00011 · Cited by 419
Computer Assisted Knee Replacement
Delp, S. L., Stulberg, D. S., Davies, B., Picard, F., & Leitner, F. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199809000-00007 · Cited by 336
Deformable models in medical image analysis
McInerney, T., & Terzopoulos, D. (1996) · Proceedings of the Workshop on Mathematical Methods in Biomedical Image Analysis · doi:10.1109/mmbia.1996.534069 · Cited by 329
Ej, L. (1997) · PubMed · Cited by 326
Grimson, W. E. L., Ettinger, G. J., White, S. J., Lozano-Perez, T., Wells, W. M., & Kikinis, R. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.491415 · Cited by 316
Cited by
Microrobots for Minimally Invasive Medicine
Nelson, B. J., Kaliakatsos, I. K., & Abbott, J. J. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-010510-103409 · Cited by 1,968
Medical robotics in computer-integrated surgery
Taylor, R. H., & Stoianovici, D. (2003) · IEEE Transactions on Robotics and Automation · doi:10.1109/tra.2003.817058 · Cited by 997
Acceptance of Healthcare Robots for the Older Population: Review and Future Directions
Broadbent, E., Stafford, R., & MacDonald, B. (2009) · International Journal of Social Robotics · doi:10.1007/s12369-009-0030-6 · Cited by 887
Automatic Multi-Organ Segmentation on Abdominal CT With Dense V-Networks
Gibson, E., Giganti, F., Hu, Y., Bonmati, E., Bandula, S., Gurusamy, K., Davidson, B., Pereira, S. P., Clarkson, M. J., & Barratt, D. C. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2806309 · Cited by 697
Robotic technology in surgery: Past, present, and future
Camarillo, D. B., Krummel, T. M., & Salisbury, J. K. (2004) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2004.08.025 · Cited by 535
A decade retrospective of medical robotics research from 2010 to 2020
Dupont, P. E., Nelson, B. J., Goldfarb, M., Hannaford, B., Menciassi, A., O’Malley, M. K., Simaan, N., Valdastri, P., & Yang, G.-Z. (2021) · Science Robotics · doi:10.1126/scirobotics.abi8017 · Cited by 516
Methods for haptic feedback in teleoperated robot‐assisted surgery
Okamura, A. M. (2004) · Industrial Robot: An International Journal · doi:10.1108/01439910410566362 · Cited by 493
Human tactile perception as a standard for artificial tactile sensing—a review
Dargahi, J., & Najarian, S. (2004) · The International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.3 · Cited by 369
Evolution of autonomous and semi‐autonomous robotic surgical systems: a review of the literature
Moustris, G. P., Hiridis, S. C., Deliparaschos, K. M., & Konstantinidis, K. M. (2011) · The International Journal of Medical Robotics and Computer Assisted Surgery · doi:10.1002/rcs.408 · Cited by 321
Medical Robots: Current Systems and Research Directions
Beasley, R. A. (2012) · Journal of Robotics · doi:10.1155/2012/401613 · Cited by 312
Automated Abdominal Multi-Organ Segmentation With Subject-Specific Atlas Generation
Wolz, R., Chu, C., Misawa, K., Fujiwara, M., Mori, K., & Rueckert, D. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265805 · Cited by 273
Qureshi, A. H., & Ayaz, Y. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2015.02.007 · Cited by 262
Metadata
- Authors
- Howe, R. D., & Matsuoka, Y.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 1999-08
- Volume
- 1
- Issue
- 1
- Pages
- 211-240
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2101637614
- Cited by
- 282
- References
- 38
- FWCI
- 0.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.