The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
NMR chemical shift imaging in three dimensions.
Open accessAbstract
A method for obtaining the three-dimensional distribution of chemical shifts in a spatially inhomogeneous sample using Fourier transform NMR is presented. The method uses a sequence of pulsed field gradients to measure the Fourier transform of the desired distribution on a rectangular grid in (k,t) space. Simple Fourier inversion then recovers the original distribution. An estimated signal/noise ratio of 20 in 10 min is obtained for an "image" of the distribution of a 10 mM phosphorylated metabolite in the human head at a field of 20 kG with 2-cm resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mapping of metabolites in whole animals by 31P NMR using surface coils
Ackerman, J. J. H., Grove, T. H., Wong, G. G., Gadian, D. G., & Radda, G. K. (1980) · Nature · doi:10.1038/283167a0 · Cited by 1,005
Spin warp NMR imaging and applications to human whole-body imaging
Edelstein, W. A., Hutchison, J. M. S., Johnson, G., & Redpath, T. (1980) · Physics in Medicine & Biology · doi:10.1088/0031-9155/25/4/017 · Cited by 803
Cited by
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
Simultaneousin vivo spectral editing and water suppression
Mescher, M., Merkle, H., Kirsch, J., Garwood, M., & Gruetter, R. (1998) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199810)11:6<266::aid-nbm530>3.0.co;2-j · Cited by 1,015
Methodological consensus on clinical proton MRS of the brain: Review and recommendations
Wilson, M., Andronesi, O., Barker, P. B., Bartha, R., Bizzi, A., Bolan, P. J., Brindle, K. M., Choi, I., Cudalbu, C., Dydak, U., et al. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27742 · Cited by 470
Magnetic resonance spectroscopy of the human brain
Ross, B., & Bluml, S. (2001) · The Anatomical Record · doi:10.1002/ar.1058 · Cited by 411
Quantitative proton MR spectroscopic imaging of the human brain
Soher, B. J., van Zijl, P. C. M., Duyn, J. H., & Barker, P. B. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350313 · Cited by 271
Metadata
- Authors
- Brown, T. R., Kincaid, B. M., & Ugurbil, K.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 1982-06
- Volume
- 79
- Issue
- 11
- Pages
- 3523-3526
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2020961426
- Cited by
- 1,039
- References
- 2
- FWCI
- 7.43
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: NMR chemical shift imaging in three dimensions. https://app.cochat.ai/papers/10.1073/pnas.79.11.3523
- The paper
- Brown, T. R., Kincaid, B. M., & Ugurbil, K. (1982). NMR chemical shift imaging in three dimensions. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.79.11.3523
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.