LAB ON A CD
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
In this paper, centrifuge-based microfluidic platforms are reviewed and compared with other popular microfluidic propulsion methods. The underlying physical principles of centrifugal pumping in microfluidic systems are presented and the various centrifuge fluidic functions, such as valving, decanting, calibration, mixing, metering, heating, sample splitting, and separation, are introduced. Those fluidic functions have been combined with analytical measurement techniques, such as optical imaging, absorbance, and fluorescence spectroscopy and mass spectrometry, to make the centrifugal platform a powerful solution for medical and clinical diagnostics and high throughput screening (HTS) in drug discovery. Applications of a compact disc (CD)-based centrifuge platform analyzed in this review include two-point calibration of an optode-based ion sensor, an automated immunoassay platform, multiple parallel screening assays, and cellular-based assays. The use of modified commercial CD drives for high-resolution optical imaging is discussed as well. From a broader perspective, we compare technical barriers involved in applying microfluidics for sensing and diagnostic use and applying such techniques to HTS. The latter poses less challenges and explains why HTS products based on a CD fluidic platform are already commercially available, whereas we might have to wait longer to see commercial CD-based diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Fundamentals of Microfabrication
(2016) · Micromechatronics · doi:10.1201/b15830-17 · Cited by 2,109
Fundamentals of Microfabrication
Madou, M. J. (2018) · CRC Press eBooks · doi:10.1201/9781482274004 · Cited by 2,020
Self-citationMicromachined Transducers Sourcebook
Kovacs, G. T. A. (1998) · Cited by 1,200
Microfabricated Centrifugal Microfluidic Systems: Characterization and Multiple Enzymatic Assays
Duffy, D. C., Gillis, H. L., Lin, J., Sheppard, N. F., & Kellogg, G. J. (1999) · Analytical Chemistry · doi:10.1021/ac990682c · Cited by 478
Design of a Compact Disk-like Microfluidic Platform for Enzyme-Linked Immunosorbent Assay
Lai, S., Wang, S., Luo, J., Lee, L. J., Yang, S.-T., & Madou, M. J. (2004) · Analytical Chemistry · doi:10.1021/ac0348322 · Cited by 418
Self-citationReagentless mechanical cell lysis by nanoscale barbs in microchannels for sample preparation
Carlo, D. D., Jeong, K.-H., & Lee, L. P. (2003) · Lab on a Chip · doi:10.1039/b305162e · Cited by 246
Hybridization Enhancement Using Cavitation Microstreaming
Liu, R. H., Lenigk, R., Druyor-Sanchez, R. L., Yang, J., & Grodzinski, P. (2003) · Analytical Chemistry · doi:10.1021/ac026267t · Cited by 244
Rapid Identification of Escherichia coli Pathotypes by Virulence Gene Detection with DNA Microarrays
Bekal, S., Brousseau, R., Masson, L., Prefontaine, G., Fairbrother, J., & Harel, J. (2003) · Journal of Clinical Microbiology · doi:10.1128/jcm.41.5.2113-2125.2003 · Cited by 181
Wang, Y., Vaidya, B., Farquar, H. D., Stryjewski, W. J., Hammer, R. P., McCarley, R. L., Soper, S. A., Cheng, Y., & Barany, F. (2003) · Analytical Chemistry · doi:10.1021/ac020683w · Cited by 170
Reduction-of-dimensionality kinetics at reaction-limited cell surface receptors
Axelrod, D., & Wang, M. D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80834-3 · Cited by 168
Cell lysis on a microfluidic CD (compact disc)
Kim, J.-T., Jang, S. H., Jia, G., Zoval, J. V., Silva, N. A. D., & Madou, M. J. (2004) · Lab on a Chip · doi:10.1039/b401106f · Cited by 151
Self-citationPortable System for Microbial Sample Preparation and Oligonucleotide Microarray Analysis
Bavykin, S. G., Akowski, J. P., Zakhariev, V. M., Barsky, V. E., Perov, A., & Mirzabekov, A. D. (2001) · Applied and Environmental Microbiology · doi:10.1128/aem.67.2.922-928.2001 · Cited by 130
Miniaturization technologies in HTS: how fast, how small, how soon?
Burbaum, J. J. (1998) · Drug Discovery Today · doi:10.1016/s1359-6446(98)01203-3 · Cited by 109
Automated microfluidic compact disc (CD) cultivation system of Caenorhabditis elegans
Kim, N., Dempsey, C. M., Zoval, J. V., Sze, J.-Y., & Madou, M. J. (2006) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2006.06.026 · Cited by 94
Self-citationMcNeely, M. R., Spute, M. K., Tusneem, N. A., & Oliphant, A. (1999) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.359339 · Cited by 52
Bourg, É. L. (1999) · Experimental Gerontology · doi:10.1016/s0531-5565(99)00004-2 · Cited by 44
A Centrifugal Microfluidic Platform — A Comparison
Madou, M. J., Lu, Y., Lai, S., Lee, J., & Daunert, S. (2000) · Springer eBooks · doi:10.1007/978-94-017-2264-3_133 · Cited by 38
Self-citation
Cited by
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Passive and active droplet generation with microfluidics: a review
Zhu, P., & Wang, L. (2017) · Lab on a Chip · doi:10.1039/c6lc01018k · Cited by 1,238
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Microfluidic platforms for lab-on-a-chip applications
Haeberle, S., & Zengerle, R. (2007) · Lab on a Chip · doi:10.1039/b706364b · Cited by 1,124
Seemann, R., Brinkmann, M., Pfohl, T., & Herminghaus, S. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/75/1/016601 · Cited by 1,049
Metadata
- Authors
- Madou, M., Zoval, J., Jia, G., Kido, H., Kim, J., & Kim, N.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2006-08-01
- Volume
- 8
- Issue
- 1
- Pages
- 601-628
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2128554309
- Cited by
- 568
- References
- 18
- FWCI
- 2.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.