The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Design of a Compact Disk-like Microfluidic Platform for Enzyme-Linked Immunosorbent Assay
Abstract
This paper presents an integrated microfluidic device on a compact disk (CD) that performs an enzyme-linked immunosorbent assay (ELISA) for rat IgG from a hybridoma cell culture. Centrifugal and capillary forces were used to control the flow sequence of different solutions involved in the ELISA process. The microfluidic device was fabricated on a plastic CD. Each step of the ELISA process was carried out automatically by controlling the rotation speed of the CD. The work on analysis of rat IgG from hybridoma culture showed that the microchip-based ELISA has the same detection range as the conventional method on the 96-well microtiter plate but has advantages such as less reagent consumption and shorter assay time over the conventional method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chiem, N., & Harrison, D. J. (1997) · Analytical Chemistry · doi:10.1021/ac9606620 · Cited by 397
Microchip Electrophoretic Immunoassay for Serum Cortisol
Koutny, L. B., Schmalzing, D., Taylor, T. A., & Fuchs, M. (1996) · Analytical Chemistry · doi:10.1021/ac9508311 · Cited by 315
Chiem, N. H., & Harrison, D. J. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.3.591 · Cited by 264
Enzyme linked immunosorbent assay on a microchip with electrochemical detection
Rossier, J. S., & Girault, H. H. (2001) · Lab on a Chip · doi:10.1039/b104772h · Cited by 164
Cited by
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Centrifugal microfluidics for biomedical applications
Gorkin, R., Park, J., Siegrist, J., Amasia, M., Lee, B. S., Park, J.-M., Kim, J., Kim, H., Madou, M., & Cho, Y.-K. (2010) · Lab on a Chip · doi:10.1039/b924109d · Cited by 731
Self-citationComputerized microfluidic cell culture using elastomeric channels and Braille displays
Gu, W., Zhu, X., Futai, N., Cho, B. S., & Takayama, S. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0404353101 · Cited by 403
A fully automated immunoassay from whole blood on a disc
Lee, B. S., Lee, J.-N., Park, J.-M., Lee, J.-G., Kim, S., Cho, Y.-K., & Ko, C. (2009) · Lab on a Chip · doi:10.1039/b820321k · Cited by 302
Thompson, B. L., Ouyang, Y., Duarte, G. R. M., Carrilho, E., Krauss, S. T., & Landers, J. P. (2015) · Nature Protocols · doi:10.1038/nprot.2015.051 · Cited by 149
Metadata
- Authors
- Lai, S., Wang, S., Luo, J., Lee, L. J., Yang, S.-T., & Madou, M. J.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-02-20
- Volume
- 76
- Issue
- 7
- Pages
- 1832-1837
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2005780072
- Cited by
- 418
- References
- 4
- FWCI
- 19.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design of a Compact Disk-like Microfluidic Platform for Enzyme-Linked Immunosorbent Assay. https://app.cochat.ai/papers/10.1021/ac0348322
- The paper
- Lai, S., Wang, S., Luo, J., Lee, L. J., Yang, S.-T., & Madou, M. J. (2004). Design of a Compact Disk-like Microfluidic Platform for Enzyme-Linked Immunosorbent Assay. Analytical Chemistry. https://doi.org/10.1021/ac0348322
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.