CoChat

A clinical, noninvasive, MR imaging-monitored ultrasound surgery method

Hynynen, K, Freund, WR, Cline, HE, Chung, AH, Watkins, RD, Vetro, JP, Jolesz, FA · 1996 · RadioGraphics
Cited by 327

The DOI matches its Crossref record.

Abstract

A noninvasive method of tissue ablation that is guided and monitored with magnetic resonance (MR) imaging has been developed. The method uses sharply focused ultrasound transducers of different focal lengths to induce a localized temperature elevation during a short exposure (1-20 seconds). A hydraulic, computer-controlled positioning device moves the transducer in an MR imager. The positioner is built into a standard cradle in the imager. The system includes cavitation detection and power monitoring circuitry for patient safety. The target volume is outlined with cross-sectional MR images obtained immediately before sonication. By means of the software, the focus is moved to ablate the volume defined with the images. The temperature elevation during the exposure is monitored by means of the proton resonance frequency shift with fast gradient-echo sequences, and the necrosed volume is demonstrated with T2-weighted fast spin-echo images. This method has been extensively tested in in vivo animal experiments and is now undergoing clinical trial.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiographics.16.1.185

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Hynynen, K., Freund, W., Cline, H., Chung, A., Watkins, R., Vetro, J., & Jolesz, F.
Venue
RadioGraphics
Published
1996-01
Volume
16
Issue
1
Pages
185-195
ISSN
  • 0271-5333 (ISSN-L)
  • 1527-1323
OpenAlex
W1995707429
Cited by
327
References
0
FWCI
16.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.