Gadolinium-enhanced ultrafast three-dimensional spoiled gradient-echo MR imaging of the abdominal aorta and visceral and iliac vessels.
The DOI matches its Crossref record.
Abstract
Gadolinium-enhanced ultrafast three-dimensional (3D) spoiled gradient-echo magnetic resonance (MR) imaging is a noninvasive method for evaluating the abdominal aorta and the visceral and iliac vessels. With an enhanced gradient system, 20-48 sections can be obtained during a single 18-32-second patient breath hold. The 3D volume obtained from a single acquisition can be reformatted at a workstation and the vascular anatomy viewed in any projection and with a variety of section thicknesses, making this MR imaging technique particularly useful in the evaluation of aberrant arteries, vascular stenoses, aneurysms, and dissection flaps. Gadolinium-enhanced ultrafast 3D spoiled gradient-echo MR imaging has been used instead of or in addition to conventional contrast material-enhanced MR angiography in patients who have chronic symptoms of mesenteric ischemia, who have abdominal aortic aneurysms, or who are at risk for iodinated contrast material-related renal dysfunction. This technique shows great promise for accurate and noninvasive evaluation of the abdominal aorta and the visceral and iliac vessels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Molecular imaging with endogenous substances
Golman, K., Ardenkjær-Larsen, J. H., Petersson, J. S., Månsson, S., & Leunbach, I. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1733836100 · Cited by 427
ACR appropriateness criteria® imaging of mesenteric ischemia
Oliva, I. B., Davarpanah, A. H., Rybicki, F. J., Desjardins, B., Flamm, S. D., Francois, C. J., Gerhard-Herman, M. D., Kalva, S. P., Ashraf Mansour, M., Mohler, E. R., et al. (2013) · Abdominal Imaging · doi:10.1007/s00261-012-9975-2 · Cited by 200
INTESTINAL (MESENTERIC) VASCULOPATHY I
Cappell, M. S. (1998) · Gastroenterology Clinics of North America · doi:10.1016/s0889-8553(05)70033-9 · Cited by 127
ACR appropriateness criteria® imaging of mesenteric ischemia
Ginsburg, M., Obara, P., Lambert, D. L., Hanley, M., Steigner, M. L., Camacho, M. A., Chandra, A., Chang, K. J., Gage, K. L., Peterson, C. M., et al. (2018) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2018.09.018 · Cited by 99
Carlos, R. C., Stanley, J. C., Stafford-Johnson, D., & Prince, M. R. (2001) · Academic Radiology · doi:10.1016/s1076-6332(03)80767-5 · Cited by 55
Metadata
- Authors
- Gilfeather, M., Holland, G. A., Siegelman, E. S., Schnall, M. D., Axel, L., Carpenter, J. P., & Golden, M. A.
- Venue
- RadioGraphics
- Published
- 1997-03
- Volume
- 17
- Issue
- 2
- Pages
- 423-432
- ISSN
- 0271-5333 (ISSN-L)
- 1527-1323
- OpenAlex
- W1991885773
- Cited by
- 51
- References
- 0
- FWCI
- 5.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Gadolinium-enhanced ultrafast three-dimensional spoiled gradient-echo MR imaging of the abdominal aorta and visceral and iliac vessels. https://app.cochat.ai/papers/10.1148/radiographics.17.2.9084082
- The paper
- Gilfeather, M., Holland, G. A., Siegelman, E. S., Schnall, M. D., Axel, L., Carpenter, J. P., & Golden, M. A. (1997). Gadolinium-enhanced ultrafast three-dimensional spoiled gradient-echo MR imaging of the abdominal aorta and visceral and iliac vessels. RadioGraphics. https://doi.org/10.1148/radiographics.17.2.9084082
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.