The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Fat Suppression in MR Imaging: Techniques and Pitfalls
Abstract
Fat suppression is commonly used in magnetic resonance (MR) imaging to suppress the signal from adipose tissue or detect adipose tissue. Fat suppression can be achieved with three methods: fat saturation, inversion-recovery imaging, and opposed-phase imaging. Selection of a fat suppression technique should depend on the purpose of the fat suppression (contrast enhancement vs tissue characterization) and the amount of fat in the tissue being studied. Fat saturation is recommended for suppression of signal from large amounts of fat and reliable acquisition of contrast material-enhanced images. The main drawbacks of this technique are sensitivity to magnetic field nonuniformity, misregistration artifacts, and unreliability when used with low-field-strength magnets. Inversion-recovery imaging allows homogeneous and global fat suppression and can be used with low-field-strength magnets. However, this technique is not specific for fat, and the signal intensity of tissue with a long T1 and tissue with a short T1 may be ambiguous. Opposed-phase imaging is a fast and readily available technique. This method is recommended for demonstration of lesions that contain small amounts of fat. The main drawback of opposed-phase imaging is unreliability in the detection of small tumors embedded in fatty tissue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Simple proton spectroscopic imaging.
Dixon, W. T. (1984) · Radiology · doi:10.1148/radiology.153.1.6089263 · Cited by 2,276
Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correction
Glover, G. H., & Schneider, E. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180211 · Cited by 687
Harms, S. E., Flamig, D. P., Hesley, K. L., Meiches, M. D., Jensen, R. A., Evans, W. P., Savino, D. A., & Wells, R. V. (1993) · Radiology · doi:10.1148/radiology.187.2.8475297 · Cited by 634
MR imaging: clinical use of the inversion recovery sequence.
Bydder, G. M., & YOUNG, I. R. (1985) · PubMed · Cited by 477
MR Imaging: Clinical Use of the Inversion Recovery Sequence
Bydder, G. M., & Young, I. R. (1985) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198507010-00002 · Cited by 426
Benign adrenocortical masses: diagnosis with chemical shift MR imaging.
Mitchell, D. G., Crovello, M., Matteucci, T., Petersen, R. O., & Miettinen, M. M. (1992) · Radiology · doi:10.1148/radiology.185.2.1410337 · Cited by 335
Disler, D. G., McCauley, T. R., Ratner, L. M., Kesack, C. D., & Cooper, J. A. (1997) · American Journal of Roentgenology · doi:10.2214/ajr.169.5.9353477 · Cited by 187
Multisection fat-water imaging with chemical shift selective presaturation.
Keller, P. J., Hunter, W. W., & Schmalbrock, P. (1987) · Radiology · doi:10.1148/radiology.164.2.3602398 · Cited by 146
MITCHELL, D. G., KIM, I., CHANG, T. S., VINITSKI, S., SAPONARO, S. A., EHRLICH, S. M., RIFKIN, M. D., & RUBIN, R. (1991) · Investigative Radiology · doi:10.1097/00004424-199112000-00002 · Cited by 131
Krinsky, G. A., Rofsky, N. M., & Weinreb, J. C. (1996) · American Journal of Roentgenology · doi:10.2214/ajr.166.3.8623620 · Cited by 121
Cited by
McRobbie, D. W., Moore, E. A., Graves, M. J., & Prince, M. R. (2017) · Cambridge University Press eBooks · doi:10.1017/9781107706958 · Cited by 752
Kwee, T. C., Takahara, T., Ochiai, R., Nievelstein, R. A. J., & Luijten, P. R. (2008) · European Radiology · doi:10.1007/s00330-008-0968-z · Cited by 410
Low‐field MRI: Clinical promise and challenges
Arnold, T. C., Freeman, C. W., Litt, B., & Stein, J. M. (2023) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.28408 · Cited by 374
Fat-Suppression Techniques for 3-T MR Imaging of the Musculoskeletal System
Del Grande, F., Santini, F., Herzka, D. A., Aro, M. R., Dean, C. W., Gold, G. E., & Carrino, J. A. (2014) · RadioGraphics · doi:10.1148/rg.341135130 · Cited by 370
Fat-containing Lesions of the Liver: Radiologic-Pathologic Correlation
Prasad, S. R., Wang, H., Rosas, H., Menias, C. O., Narra, V. R., Middleton, W. D., & Heiken, J. P. (2005) · RadioGraphics · doi:10.1148/rg.252045083 · Cited by 300
Metadata
- Authors
- Delfaut, E. M., Beltran, J., Johnson, G., Rousseau, J., Marchandise, X., & Cotten, A.
- Venue
- RadioGraphics
- Published
- 1999-03
- Volume
- 19
- Issue
- 2
- Pages
- 373-382
- ISSN
- 0271-5333 (ISSN-L)
- 1527-1323
- OpenAlex
- W2167797960
- Cited by
- 487
- References
- 12
- FWCI
- 6.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fat Suppression in MR Imaging: Techniques and Pitfalls. https://app.cochat.ai/papers/10.1148/radiographics.19.2.g99mr03373
- The paper
- Delfaut, E. M., Beltran, J., Johnson, G., Rousseau, J., Marchandise, X., & Cotten, A. (1999). Fat Suppression in MR Imaging: Techniques and Pitfalls. RadioGraphics. https://doi.org/10.1148/radiographics.19.2.g99mr03373
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.