The DOI matches its Crossref record.
Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correction
Abstract
An enhancement to Dixon's technique is described which can provide error‐free decomposition of water and fat proton images even in the presence of off‐resonance conditions which result from susceptibility differences, demagnetization, or shim errors. The method uses three measurements with phase shifts of 0, π and − π between the fat and water resonances. The additional information provided by the third measurement is used to calculate an image of the field inhomogeneity in addition to true water and fat images. The signal‐to‐noise ratio (SNR) in the decomposed images is equivalent to that of a 2.7 NEX acquisition (instead of 3 NEX), yielding an SNR imaging efficiency of 95%. In addition, the B0 image which is provided may have diagnostic value in its own right. Examples of head and body scans often portray surprisingly large B0 shifts near interfaces between air or bone and soft tissue. © 1991 Academic Press. Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lim, E. L., Hollingsworth, K. G., Aribisala, B. S., Chen, M. J., Mathers, J. C., & Taylor, R. (2011) · Diabetologia · doi:10.1007/s00125-011-2204-7 · Cited by 1,164
Quantitative susceptibility mapping: current status and future directions
Haacke, E. M., Liu, S., Buch, S., Zheng, W., Wu, D., & Ye, Y. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.09.004 · Cited by 511
Liu, T., Spincemaille, P., de Rochefort, L., Kressler, B., & Wang, Y. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21828 · Cited by 454
Dual‐echo Dixon imaging with flexible choice of echo times
Eggers, H., Brendel, B., Duijndam, A., & Herigault, G. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22578 · Cited by 320
Steven (2016) · doi:10.2337/dc15-0750 · Cited by 171
Metadata
- Authors
- Glover, G. H., & Schneider, E.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1991-04
- Volume
- 18
- Issue
- 2
- Pages
- 371-383
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2026084370
- Cited by
- 687
- References
- 0
- FWCI
- 8.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correction. https://app.cochat.ai/papers/10.1002/mrm.1910180211
- The paper
- Glover, G. H., & Schneider, E. (1991). Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correction. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910180211
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.