Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correction

Glover, G. H., Schneider, E.·1991·Magnetic Resonance in Medicine

Abstract

An enhancement to Dixon's technique is described which can provide error‐free decomposition of water and fat proton images even in the presence of off‐resonance conditions which result from susceptibility differences, demagnetization, or shim errors. The method uses three measurements with phase shifts of 0, π and − π between the fat and water resonances. The additional information provided by the third measurement is used to calculate an image of the field inhomogeneity in addition to true water and fat images. The signal‐to‐noise ratio (SNR) in the decomposed images is equivalent to that of a 2.7 NEX acquisition (instead of 3 NEX), yielding an SNR imaging efficiency of 95%. In addition, the B0 image which is provided may have diagnostic value in its own right. Examples of head and body scans often portray surprisingly large B0 shifts near interfaces between air or bone and soft tissue. © 1991 Academic Press. Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.1910180211

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 687

Metadata

Authors
Glover, G. H., & Schneider, E.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
1991-04
Volume
18
Issue
2
Pages
371-383
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2026084370
Cited by
687
References
0
FWCI
8.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correction. https://app.cochat.ai/papers/10.1002/mrm.1910180211
The paper
Glover, G. H., & Schneider, E. (1991). Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correction. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910180211

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.