Cited by 67Radiopharmaceutical Chemistry and ApplicationsRadiation Dose and ImagingMedical Imaging Techniques and Applications

The AAPM/RSNA Physics Tutorial for Residents: Internal Radiation Dosimetry: Principles and Applications(CME available in print version and on RSNA Link)

Toohey, Richard E., Stabin, Michael G., Watson, Evelyn E.·2000·RadioGraphics

Abstract

Internal dose calculations in nuclear medicine normally use the techniques, equations, and resources provided by the Medical Internal Radiation Dose (MIRD) Committee of the Society of Nuclear Medicine. The MIRD schema uses a unique set of symbols and quantities to calculate the absorbed dose of radiation in any target organ per radioactive decay in any source organ. The calculations involve the energy emitted per radioactive decay, the fraction of the emitted energy that is absorbed in various target organs, the masses of these organs, and both the physical decay and biologic clearance of the injected radioactive material. Standardized mathematical models (phantoms) of the human body and standardized biokinetic models are also used. A computer program, MIRDose, calculates dose tables per unit administered activity of various radiopharmaceuticals. Special care must be taken when nuclear medicine procedures involve pregnant or lactating patients. New methodologies are becoming available to calculate doses to individual patients.

Integrity signals

Registry

Crossref · 10.1148/radiographics.20.2.g00mc33533

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Toohey, R. E., Stabin, M. G., & Watson, E. E.
Affiliations
Oak Ridge Institute for Science and Education (US)
Venue
RadioGraphics
Published
2000-03
Volume
20
Issue
2
Pages
533-546
ISSN
  • 0271-5333 (ISSN-L)
  • 1527-1323
OpenAlex
W2142440494
Cited by
65
References
10
Citations by year
2026: 2 · 2025: 2 · 2024: 2 · 2023: 3 · 2022: 3 · 2021: 7 · 2020: 1 · 2019: 2 · 2018: 2 · 2017: 2 · 2016: 3 · 2015: 2 · 2014: 5 · 2013: 3 · 2012: 2
FWCI
1.26
Type
journal article
Language
en
Open access
closed
Locations
  • Radiographics (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiopharmaceutical Chemistry and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
Keywords
internal dose calculation, MIRD schema, medical internal radiation dose, absorbed dose, biokinetic models, phantoms, radiopharmaceuticals, pregnancy and lactation
MeSH terms
Adolescent, Adult, Age Factors, Algorithms, Child, Child, Preschool, Computer Simulation, Female, Fetus, Half-Life, Humans, Infant, Lactation, Metabolic Clearance Rate, Models, Biological, Monte Carlo Method, Pregnancy, Radiation Dosage, Radiometry, Relative Biological Effectiveness, Whole-Body Counting, Phantoms, Imaging, Radiopharmaceuticals

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review