MR Imaging Classification of Perianal Fistulas and Its Implications for Patient Management
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Until recently, imaging had a limited role in the preoperative assessment of perianal fistulas. Magnetic resonance (MR) imaging has been shown to demonstrate accurately the anatomy of the perianal region. In addition to showing the anal sphincter mechanism, MR imaging clearly shows the relationship of fistulas to the pelvic diaphragm (levator plate) and the ischiorectal fossae. This relationship has important implications for surgical management and outcome and has been classified into five MR imaging-based grades. If the ischioanal and ischiorectal fossae are unaffected, disease is likely confined to the sphincter complex (simple intersphincteric fistulization, grade 1 or 2), and outcome following simple surgical management is favorable. Involvement of the ischioanal or ischiorectal fossa by a fistulous track or abscess indicates complex disease related to trans-sphincteric or suprasphincteric disease (grade 3 or 4). Correspondingly more complex surgery may be required that may threaten continence or may require colostomy to allow healing. If the track traverses the levator plate, a translevator fistula (grade 5) is present, and a source of pelvic sepsis should be sought.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A classification of fistula-in-ano
Parks, A. G., Gordon, P. H., & Hardcastle, J. D. (1976) · Journal of British Surgery · doi:10.1002/bjs.1800630102 · Cited by 1,663
Pelvic and perineal complications of Crohn's disease: assessment using magnetic resonance imaging.
Haggett, P. J., Moore, N. R., Shearman, J. D., Travis, S. P., Jewell, D. P., & Mortensen, N. J. (1995) · Gut · doi:10.1136/gut.36.3.407 · Cited by 189
Diagnosis of fistulae and sinus tracts in patients with Crohn disease: value of MR imaging
Koelbel, G., Schmiedl, U., Majer, M., Weber, P., Jenss, H., Kueper, K., & Hess, C. (1989) · American Journal of Roentgenology · doi:10.2214/ajr.152.5.999 · Cited by 158
Cited by
Bruining, D. H., Zimmermann, E. M., Loftus, E. V., Sandborn, W. J., Sauer, C. G., Strong, S. A., & Society of Abdominal Radiology Crohn’s Disease-Focused Panel (2018) · Radiology · doi:10.1148/radiol.2018171737 · Cited by 336
Perianal fistulizing Crohn's disease: pathogenesis, diagnosis and therapy
Panés, J., & Rimola, J. (2017) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/nrgastro.2017.104 · Cited by 308
Bruining, D. H., Zimmermann, E. M., Loftus, E. V., Sandborn, W. J., Sauer, C. G., Strong, S. A., Al-Hawary, M., Anupindi, S., Baker, M. E., Bruining, D., et al. (2018) · Gastroenterology · doi:10.1053/j.gastro.2017.11.274 · Cited by 234
Indications for abdominal imaging: when and what to choose?
Department of Medical Imaging, “. H. U. O. M. A. P., Caraiani, C., Yi, D., Department of Ultrasound, Z. H., Petresc, B., Department of Medical Imaging, “. H. U. O. M. A. P., Dietrich, C., & Department Allgemeine Innere Medizin, K. H. B. B. S. (2020) · Journal of Ultrasonography · doi:10.15557/jou.2020.0008 · Cited by 66
Metadata
- Authors
- Morris, J., Spencer, J. A., & Ambrose, N. S.
- Venue
- RadioGraphics
- Published
- 2000-05
- Volume
- 20
- Issue
- 3
- Pages
- 623-635
- ISSN
- 0271-5333 (ISSN-L)
- 1527-1323
- OpenAlex
- W2153433811
- Cited by
- 438
- References
- 3
- FWCI
- 3.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.